Item No.:
20
|
|
Site:
Other-MAIN COLD GALLEY AND VERA
|
|
Violation:
The interiors of the ice bins had cracked plastic and peeling sealant.
|
|
Recommendation:
Food-contact and ice-contact surfaces must be constructed of materials that are nontoxic, smooth, corrosion-resistant, nonabsorbent, and durable under conditions of normal use. Food-contact surfaces also must be easily cleanable and free of difficult-to-clean internal corners, crevices, and fasteners.
|
|
|
Item No.:
20
|
|
Site:
Other-WINDSPIRIT LOUNGE PANTRY
|
|
Violation:
The ice bin had rough sealant, rust, and seams. This bin should be replaced.
|
|
Recommendation:
Food-contact surfaces also must be easily cleanable and free of difficult-to-clean internal corners, crevices, and fasteners.
|
|
|
Item No.:
21
|
|
Site:
Other-VERANDAH GALLEY
|
|
Violation:
The new grill was not sealed to the counter or elevated on 4-inch legs.
|
|
Recommendation:
Equipment that is placed on tables or counters, unless portable, shall be sealed to the table or counter or elevated on legs to provide at least a 4-inch clearance between the table or counter and shall be installed to facilitate the cleaning of the equipment and adjacent areas.
|
|
|
Item No.:
21
|
|
Site:
Other-VERANDAH GALLEY
|
|
Violation:
Stainless steel conduit should be provided for the long electrical chords to the appliances.
|
|
Recommendation:
|
|
|
Item No.:
21
|
|
Site:
Other-ICE CREAM STATION
|
|
Violation:
The top of the ice cream freezer had holes where screws were removed.
|
|
Recommendation:
Surfaces of equipment not intended for contact with food, but which are exposed to splash or food debris or which otherwise require frequent cleaning, shall be designed and fabricated to be smooth, washable, free of unnecessary ledges, projections, or crevices, and readily accessible for cleaning, and shall be of such material and in such repair as to be easily maintained in a clean and sanitary condition.
|
|
|
Item No.:
21
|
|
Site:
Other-MAIN HOT GALLEY
|
|
Violation:
Peeling sealant was noted where the hood above the kettle and convection oven was attached to the bulkhead. Also, peeling sealant was noted where the control box for the small kettle was mounted on the tabletop.
|
|
Recommendation:
Surfaces of equipment not intended for contact with food, but which are exposed to splash or food debris or which otherwise require frequent cleaning, shall be designed and fabricated to be smooth, washable, free of unnecessary ledges, projections, or crevices, and readily accessible for cleaning, and shall be of such material and in such repair as to be easily maintained in a clean and sanitary condition.
|
|
|
Item No.:
21
|
|
Site:
Other-MAIN HOT GALLEY
|
|
Violation:
Rough sealant was noted around the control panel to the Wells grill.
|
|
Recommendation:
Nonfood preparation equipment must be easily cleanable, in good repair, and corrosion-resistant.
|
|
|
Item No.:
21
|
|
Site:
Other-MAIN GALLEY BAKERY
|
|
Violation:
The hood canopy located above the oven had frayed wiring, rough sealant, and corrosion which presented difficult-to-clean surfaces.
|
|
Recommendation:
Surfaces of equipment not intended for contact with food, but which are exposed to splash or food debris or which otherwise require frequent cleaning, shall be designed and fabricated to be smooth, washable, free of unnecessary ledges, projections, or crevices, and readily accessible for cleaning, and shall be of such material and in such repair as to be easily maintained in a clean and sanitary condition.
|
|
|
Item No.:
21
|
|
Site:
Other-MAIN HOT GALLEY
|
|
Violation:
The bottoms of the lower ovens and the exterior framing were heavily rusted.
|
|
Recommendation:
Nonfood preparation equipment must be easily cleanable, in good repair, and corrosion-resistant.
|
|
|
Item No.:
21
|
|
Site:
Other-MAIN HOT GALLEY
|
|
Violation:
The plate warmer cabinet had seams, rough sealant, and a hole inside of it.
|
|
Recommendation:
Surfaces of equipment not intended for contact with food, but which are exposed to splash or food debris or which otherwise require frequent cleaning, shall be designed and fabricated to be smooth, washable, free of unnecessary ledges, projections, or crevices, and readily accessible for cleaning, and shall be of such material and in such repair as to be easily maintained in a clean and sanitary condition.
|
|
|
Item No.:
28
|
|
Site:
Other-MAIN HOT GALLEY
|
|
Violation:
Some previously washed pans were found soiled with grease and food residue.
|
|
Recommendation:
To prevent cross-contamination, pots, pans, utensils and other food contact surfaces of equipment shall be thoroughly washed, rinsed and sanitized after each use and prior to storage. Any items which are found to be soiled after being washed, must be returned to the warewashing area for immediate re-washing.
|
|
|
Item No.:
28
|
|
Site:
Other-MAIN POTWASH
|
|
Violation:
Previously washed pots, pans, and utensils were found soiled with grease and food residue. Also, the table in which they were stored on was soiled with food.
|
|
Recommendation:
To prevent cross-contamination, pots, pans, utensils and other food contact surfaces of equipment shall be thoroughly washed, rinsed and sanitized after each use and prior to storage. Any items which are found to be soiled after being washed, must be returned to the warewashing area for immediate re-washing.
|
|
|
Item No.:
28
|
|
Site:
Other-MAIN GALLEY - COFFEE AND
|
|
Violation:
The food preparation counter under the tray and toaster was soiled with food residue.
|
|
Recommendation:
Food shall be prepared on surfaces that prior to use have been cleaned, rinsed and sanitized.
|
|
|
Item No.:
29
|
|
Site:
Other-MAIN HOT GALLEY
|
|
Violation:
Heavy grease residues were present on the underside of the grill. The surface was inaccessible for cleaning.
|
|
Recommendation:
Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
|
|
|
Item No.:
29
|
|
Site:
Other-MAIN HOT GALLEY
|
|
Violation:
The table located below the steamer was soiled with food residue.
|
|
Recommendation:
Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
|
|
|
Item No.:
29
|
|
Site:
Other-MAIN HOT GALLEY
|
|
Violation:
The underside of the shelf above the bain-marie was soiled with food splash.
|
|
Recommendation:
Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
|
|
|
Item No.:
29
|
|
Site:
Other-MAIN GALLEY PASTRY
|
|
Violation:
Dust was present on the wiring and around the exhaust fan in the hood canopy above the Pastry oven. Also, grease and food residue was present on the table underneath the small mixer legs.
|
|
Recommendation:
Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
|
|
|
Item No.:
29
|
|
Site:
Other-MAIN HOT GALLEY
|
|
Violation:
Some food residue was present in the plate warmer cabinet.
|
|
Recommendation:
Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
|
|
|
Item No.:
37
|
|
Site:
Other-FOOD PREPARATION AND STOR
|
|
Violation:
An outside pest control exterminator was observed using a crack and crevice insecticide. The contractor was spraying countertops, undersides of food preparation tables, and into the technical compartments on top of the upright refrigerators. The insecticide "Commoodore WP" was approved only for crack and crevice application and not allowed for use in USDA meat and poultry plants according to the labeling.
|
|
Recommendation:
Poisonous or toxic materials shall not be stored or used in a way that contaminates food, equipment, or utensils, in a way that constitutes a hazard to employees or other persons, or in a way other than in full compliance with the manufacturer's labeling. Only those pesticides approved for use in food establishments may be used in food service or warewashing areas. These products must be applied in a manner consistent with their labeling. No pesticide may be applied in a manner which poses the potential for contamination of food products, food contact surfaces or food equipment.
|
|
|
Item No.:
38
|
|
Site:
Other-MAIN GALLEY - GENERAL
|
|
Violation:
Deck surfaces under and around cooking equipment were pitted and peeling. Also, some deck tiles were cracked or chipped and grouting material was missing.
|
|
Recommendation:
Decks, bulkheads, and deckheads in food preparation, warewashing, and storage areas, including pantries, shall be designed and constructed for easy cleanability, shall be corrosion-resistant, maintained in good repair, and kept clean.
|
|
|
Item No.:
40
|
|
Site:
Other-MAIN SCULLERY
|
|
Violation:
The steam and heat was not adequately exhausted from the glasswashing machine.
|
|
Recommendation:
Ventilation systems shall be adequately designed to remove a large percentage of the hot humid air in food service areas to prevent workers from perspiring profusely and to prevent the accumulation of condensation on deckheads.
|
|