Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Crystal Symphony Cruise Line: Crystal Cruises LTD Inspection Date: 12/22/1996 Inspection Score: 95
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 40
Site: Other-LIDO FOOD SERVICE
Violation: Condensation had formed on the deckhead above the dishwashing machines. This was also true in the Trident Bar pantry.
Recommendation: Ventilation systems shall be adequately designed to remove a large percentage of the hot humid air in food service areas to prevent workers from perspiring profusely and to prevent the accumulation of condensation on deckheads.
Item No.: 26
Site: Other-LIDO FOOD SERVICE
Violation: The final sanitizing rinse water for the glasswashing machine was 144oF, as measured during operation at the dish level.
Recommendation: Automatic dishwashing machines utilizing hot water for sanitizing shall operate at a minimum of 165oF (74oC) measured at dish level.
Item No.: 26
Site: Other-SCULLERY - DECK 5
Violation: The final sanitizing rinse cycle on the dishwashing machine was not operating. This was corrected during the inspection.
Recommendation: Automatic dishwashing machines utilizing hot water for sanitizing shall operate at a minimum of 165oF (74oC) measured at dish level.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program