Item No.:
28
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
The can opener blade was soiled with an accumulation of food residue.
|
|
Recommendation:
All food preparation equipment, utensils, tableware, other food contact surfaces and food storage containers shall be washed, rinsed, and sanitized after every use or change in use. A food surface is that surface of equipment or utensil with which food normally comes in contact and those surfaces from which food may drip, drain, or splash back onto other surfaces normally in contact with food.
|
|
|
Item No.:
29
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
The base of the can opener was soiled with food residue. Also, the base of the can opener was not installed properly and there was a seam that accumulated food residue.
|
|
Recommendation:
The base of the can opener shall be properly sealed to the working table and be kept clean.
|
|
|
Item No.:
21
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
The working counter top that held the can opener was not welded to the base of the table and there was a large exposed gap.
|
|
Recommendation:
The table top must be re-welded.
|
|
|
Item No.:
38
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
The ducts over the combi ovens were heavily soiled with grease.
|
|
Recommendation:
Intake and exhaust air ducts shall be maintained to prevent the entrance of dust, dirt, and other contaminating materials.
|
|
|
Item No.:
29
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
The sealant in the hood above the grills and fryers was peeling and the seams were soiled with grease.
|
|
Recommendation:
Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris. The sealant shall be replaced.
|
|
|
Item No.:
29
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
The fan inside the hot plate storage cabinet was soiled with dust.
|
|
Recommendation:
Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
|
|
|
Item No.:
28
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
The interiors of the ice machines were soiled with mold.
|
|
Recommendation:
All food preparation equipment, utensils, tableware, other food contact surfaces and food storage containers shall be washed, rinsed, and sanitized after every use or change in use. A food surface is that surface of equipment or utensil with which food normally comes in contact and those surfaces from which food may drip, drain, or splash back onto other surfaces normally in contact with food.
|
|
|
Item No.:
38
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
The ventilation duct grills above the ice machines were soiled with dust.
|
|
Recommendation:
Decks, bulkheads, deckheads and attached equipment shall be kept clean.
|
|
|
Item No.:
30
|
|
Site:
Other-MAIN GALLEY SCULLERY
|
|
Violation:
The employee removing clean dishes from the dish racks was not wearing gloves. He was also handling soiled trays and did not wash his hands between soiled and clean handling operations.
|
|
Recommendation:
Cleaned and sanitized equipment and utensils shall be handled and stored in a way that protects them from contamination. Personnel must wash hands after handling soiled equipment and before handling clean dishes and utensils.
|
|
|
Item No.:
22
|
|
Site:
Other-MAIN GALLEY SCULLERY
|
|
Violation:
Plate covers were not racked properly and proper exposure of wash and rinse waters on the food contact surfaces was obstructed.
|
|
Recommendation:
Equipment and utensils shall be placed in racks, trays, baskets or on conveyors so that food-contact surfaces are exposed to the unobstructed application of detergent wash and clean rinse waters and free draining occurs.
|
|
|
Item No.:
30
|
|
Site:
Other-POTWASH
|
|
Violation:
Only one employee was assigned to the Potwash operation and he handled both soiled and clean items without washing hands between operations.
|
|
Recommendation:
To prevent contamination of clean equipment, personnel handling soiled equipment must wash hands before handling clean equipment.
|
|
|
Item No.:
38
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
The deck tiles at the bases of the pillars were cracked or missing.
|
|
Recommendation:
The tiles shall be repaired.
|
|
|
Item No.:
38
|
|
Site:
Other-CREW MESS
|
|
Violation:
The base of the serving counter and deck interface had seams that were not easily cleanable. The deck was not coved at the interface with the serving counter and there was exposed raw steel.
|
|
Recommendation:
Deck and equipment junctures shall be coved and of a material that is hard, smooth, easily cleanable, and non-corrosive.
|
|
|
Item No.:
21
|
|
Site:
Other-CREW MESS
|
|
Violation:
There were many gaps that were not easily cleanable at the dirty drop-off window to the Crew Scullery.
|
|
Recommendation:
The gaps shall be sealed.
|
|