Item No.:
20
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Ice bin deflectors were not removeable making it difficult to clean the interior of the ice bin.
|
|
Recommendation:
Food and ice contact surfaces must be easily cleanable and free of difficult-to-clean internal corners, crevices, and fasteners.
|
|
|
Item No.:
20
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Sealant was missing or partially missing on two food slicers.
|
|
Recommendation:
Food preparation equipment must be easily cleanable and maintained in good repair.
|
|
|
Item No.:
28
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
The seal at the base of the food chopper was soiled with food debris.
|
|
Recommendation:
To prevent cross-contamination, food contact surfaces of equipment, including the gaskets and seal on the food chopper, shall be thoroughly washed, rinsed and sanitized after each use and prior to storage.
|
|
|
Item No.:
40
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
There was a small amount of condensation on the deckhead over the soiled end of the potwash machine.
|
|
Recommendation:
Ventilation systems shall be adequately designed to remove a large percentage of the hot humid air in food service areas to prevent workers from perspiring profusely and to prevent the accumulation of condensation on deckheads.
|
|
|
Item No.:
21
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
The undersides of the skillets and a pressure cooker had large gaps making them difficult-to-clean.
|
|
Recommendation:
Surfaces of equipment not intended for contact with food, but which are exposed to splash or food debris or which otherwise require frequent cleaning, shall be designed and fabricated to be smooth, washable, free of unnecessary ledges, projections, or crevices, and readily accessible for cleaning, and shall be of such material and in such repair as to be easily maintained in a clean and sanitary condition.
|
|
|
Item No.:
23
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Some of the dishwashing temperature gauges were inaccurate and some machines were missing pressure gauges.
|
|
Recommendation:
Machine or water line-mounted, numerically scaled, indicating thermometers, accurate to +3oF (+1.5oC), shall be provided to indicate the temperature of the water in each tank of the machine and the temperature of the final rinse water as it enters the manifold.
|
|
|
Item No.:
39
|
|
Site:
Other-PROVISIONS
|
|
Violation:
Lighting in several walk-in freezers was less than adequate.
|
|
Recommendation:
Permanently fixed artificial light sources shall be installed to provide, at a distance 30-inches from the deck, at least 20-footcandles of light in utensil and equipment storage areas and at least 10-footcandles of light in walk-in refrigerating units and dry food storage areas.
|
|
|
Item No.:
9
|
|
Site:
Other-JADE GARDEN PANTRY
|
|
Violation:
One bottle of soy sauce was not labeled.
|
|
Recommendation:
Containers or bottles of food shall be clearly labeled. If the label is inadvertently removed, then the item must be relabeled with the common name.
|
|
|
Item No.:
17
|
|
Site:
Other-BARS
|
|
Violation:
One ice scoop was found stored in an ice bin with the handle in contact with the ice.
|
|
Recommendation:
Ice dispensing utensils shall be stored on a clean surface, on hooks fastened to the interior or exterior of the ice machine, on retractable devices attached to the bulkhead or deckhead, or in the ice with the handle extended out of the ice.
|
|