Cruise Ship: Wind Spirit Cruise Line: Windstar Cruises Inspection Date: 01/12/1998 Inspection Score: 98
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 4
Site: Other-Laundry
Violation: Ensure that the potable water lines to the 2-compartment sink are protected with backflow preventers.
Recommendation:
Item No.: 30
Site: Other-Main Galley-Dishwashing
Violation: Cleaned utensils were hanging along the bulkhead on the dirty side of the pot wash area and soiled pans and utensils were stored on a rack on the clean side of the port wash operation.
Recommendation: Adequate space and shelving shall be provided for the storage of clean utensils and equipment and shall be located and designed to prevent contamination.
Item No.: 38
Site: Other-Veranda Café
Violation: Wooden construction at the hot buffet area and open crevices resulted in non-easily cleanable surfaces. Also, the narrow space between the counter and the bulkhead of the hot table and the bain-marie was not easily cleanable.
Recommendation: Decks, bulkheads, and deckheads in food preparation, warewashing, and storage areas, including pantries, shall be designed and constructed for easy cleanability, shall be corrosion-resistant, maintained in good repair, and kept clean.
Item No.: 7
Site: Other-Crew mess
Violation: The water spigot to the bain marie interferes with the placement of the serving pans. It is recommended that a faucet with a swivel spigot is provided.
Recommendation:
Item No.: 38
Site: Other-Dry Stores
Violation: Decking below storage racks was soiled with dust and food debris.
Recommendation: Decks, bulkheads, and deckheads in food preparation, warewashing, and storage areas, including pantries, shall be designed and constructed for easy cleanability, shall be corrosion-resistant, maintained in good repair, and kept clean.
Item No.: 30
Site: Other-Main Galley-Dishwashing
Violation: Clean plates were stored on a mobile plate holding unit in close proximity to the garbage grinder shute.
Recommendation: Cleaned and sanitized utensils and equipment shall be stored at least 6-inches above the floor in a clean, dry location in a way that protects them from contamination by splash, dust, and other means.