Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Silver Cloud Cruise Line: Silversea Inspection Date: 12/28/1998 Inspection Score: 91
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 38
Site: Other-MAIN GALLEY-BAKERY
Violation: One of the bulkheads was damaged leaving an open seam at the deck juncture.
Recommendation: Repair the bulkhead and seal the open seam at the deck juncture.
Item No.: 28
Site: Other-MAIN GALLEY-BAKERY
Violation: Standing water was present in the removable sleeves on the mixer heads over the mixing bowls.
Recommendation: Remove and clean the sleeves so that there is no standing water.
Item No.: 22
Site: Other-MAIN GALLEY-POT WASH
Violation: Employees were not using the hold-down rack in the pot washing machine and pans placed in the machine were flipping over and filling with water.
Recommendation: Invert pots and pans placed in the machine and hold them in place with the hold-down rack so that they are properly washed in the machine.
Item No.: 22
Site: Other-MAIN GALLEY-POT WASH
Violation: The doors on the pot washing machine were difficult to open and did not close completely allowing steam to escape and condense on the exhaust hood over the machine.
Recommendation: Repair the doors so that they operate smoothly and close completely.
Item No.: 38
Site: Other-ELEVATOR TO THE GALLEY
Violation: The coving at the bulkhead/deck juncture was detached leaving a large open seam.
Recommendation: Repair and seal the coving at the bulkhead/deck juncture.
Item No.: 29
Site: Other-MAIN GALLEY-HOT GALLEY
Violation: There was a heavy build-up of grease in all of the hood exhaust ducts located over frying equipment.
Recommendation: Clean the ducts over the exhaust hoods.
Item No.: 22
Site: Other-MAIN GALLEY-HOT GALLEY
Violation: An employee washed, rinsed and sanitized a soiled knife using the three bucket method instead of taking the knife to a three compartment sink. Additionally, he did not sanitize the knife for a full minute in the chlorine solution.
Recommendation: Wash, rinse and sanitize utensils in a three compartment sink or dishwashing machine instead of using the three bucket method. Sanitize utensils for at least a minute.
Item No.: 38
Site: Other-MAIN GALLEY-HOT GALLEY
Violation: Deck grouting between tiles was recessed beneath the tilt skillets.
Recommendation: Replace recessed deck grouting. It is required that decks be maintained so as to be durable and easily cleanable.
Item No.: 11
Site: Other-MAIN GALLEY-HOT GALLEY
Violation: Cooked, diced ham and strips of smoked salmon were found at 50oF in an ice bath for omelets. The ice was almost completely melted. Reportedly, these items were on ice less than 2 hours.
Recommendation: Potentially hazardous food requiring refrigeration shall be stored at or below 45oF. When using ice, replenish it periodically to maintain safe food temperatures.
Item No.: 15
Site: Other-PROVISIONS
Violation: Pre-cooked sausages and hot dogs were found thawing in the butcher shop with raw poultry and beef.
Recommendation: To avoid cross-contamination, do not open and thaw pre-cooked or ready-to-eat foods in the butcher shop where raw meats are processed.
Item No.: 21
Site: Other-PROVISIONS
Violation: Bags of bulk flour and rice were stored on a piece of unfinished wooden shelving placed on stainless steel stands.
Recommendation: Do not store bulk bags of food on unfinished wooden shelving.
Item No.: 14
Site: Other-PROVISIONS
Violation: Cases of frozen meats and fresh produce were stored directly on the deck.
Recommendation: Do not store cases of food directly on the deck where it is subject to contamination.
Item No.: 22
Site: Other-CREW GALLEY-DISHWASHING
Violation: Four upper and one lower spray jet were obstructed on the final sanitizing rinse.
Recommendation: Inspect and clean spray jets as required. Dishes and utensils must be cleaned and sanitized utilizing spray-type dishwashing machines. These machines shall be properly installed and maintained in good repair. Machines shall be operated in accordance with manufacturers' instructions, and utensils and equipment placed in the machine shall be exposed to all dishwashing cycles. All automatic detergent dispensers, wetting agent dispensers, and liquid sanitizer injectors shall be properly installed and maintained.
Item No.: 30
Site: Other-CREW GALLEY-DISHWASHING
Violation: A rack of soiled, pre-flushed dishes was found stored in the racks of clean dishes.
Recommendation: Do not store or place racks of soiled dishes in clean storage areas.
Item No.: 20
Site: Other-CREW GALLEY
Violation: The interior of the oven including the door had many cracks, crevices and holes.
Recommendation: Food-contact and ice-contact surfaces must be constructed of materials that are nontoxic, smooth, corrosion-resistant, nonabsorbent and durable under conditions of normal use. Food-contact surfaces also must be easily cleanable and free of difficult-to-clean internal cracks, crevices, holes and fasteners.
Item No.: 29
Site: Other-CREW GALLEY
Violation: The exhaust hood ducts had a heavy build-up of grease.
Recommendation: Clean the ducts over exhaust hoods.
Item No.: 10
Site: Other-TERRACE CAFÉ-LIDO SERVICE
Violation: The following items were out of temperature on the buffet line: cheese 58oF, luncheon meat 63oF, sliced melons 61oF.
Recommendation: It is required that potentially hazardous food be maintained at safe temperatures (45oF or below, 140oF or above) on buffet lines.
Item No.: 11
Site: Other-TERRACE CAFÉ-LIDO
Violation: Although proper facilities for keeping food cold on the buffet were available, plates and table clothes were placed on top of the ice and then trays of food were placed on the table cloths preventing foods from coming in close contact to the ice and staying cold.
Recommendation: Avoid using plates and table cloths on top of ice so as not to interfere with the chilling of food.
Item No.: 39
Site: Other-TERRACE CAFÉ-LIDO
Violation: Lighting was inadequate at the coffee station behind the buffet counter.
Recommendation: Provide additional lighting to insure at least 20 foot candles of light in all food preparation areas.
Item No.: 30
Site: Other-TERRACE CAFÉ-LIDO
Violation: The pantry pot wash area had inadequate space for storing soiled and clean pots and pans. Soiled items were stored on a clean countertop above undercounter refrigerators were food was stored.
Recommendation: Provide additional storage space for soiled pots and pans. Cleaned and sanitized equipment and utensils shall be handled and stored in a way that protects them from contamination.
Item No.: 20
Site: Other-PANORAMA BAR PANTRY
Violation: The interior of the ice machine bin was corroded and had slotted screws making it difficult to clean.
Recommendation: Food-contact and ice-contact surfaces must be constructed of materials that are nontoxic, smooth, corrosion-resistant, nonabsorbent and durable under conditions of normal use. Food-contact surfaces also must be easily cleanable and free of difficult-to-clean internal corners, crevices and fasteners.
Item No.: 38
Site: Other-VENETIAN LOUNGE SERVICE BAR
Violation: The doorway into the service bar at the door threshold was separated and food debris was collecting in the space. Additionally, the bulkhead profile along the base of the doorway was damaged leaving a large gap.
Recommendation: Repair the doorway threshold and bulkhead profile. Decks, bulkheads, and deckheads in food preparation areas, including pantries, shall be designed and constructed for easy cleanability, shall be corrosion-resistant, maintained in good repair and kept clean.
Item No.: 41
Site: Other-MAIN BAR PANTRY
Violation: Floor mops were found stored in a bucket in the pantry.
Recommendation: Place mops in cleaning lockers designed for that purpose.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program