Item No.:
7
|
|
Site:
Other-FOOD SERVICE GENERAL - LIDO / BARS
|
|
Violation:
THE WALK IN COOLERS HAVE CONDENSATION ON BOTTOM OF CHILLER DRIP PANS WHICH WAS FALLING ON TO FOOD CONTAINERS AND THE DECK BELOW. THE DRIP PANS APPEARED TO BE TOO SMALL TO CATCH ALL OF THE CONDENSATION FORMED ON THE CHILLER.
|
|
Recommendation:
Wastewater from equipment and sinks must be properly drained to prevent pooling or leaking of water on the deck.
|
|
|
Item No.:
20
|
|
Site:
Other-FOOD SERVICE GENERAL - LIDO / BARS
|
|
Violation:
THE GASKETS ON THE ICE MACHINES WERE CONSTRUCTED OF AN OPEN CELL MATERIAL WHICH ABSORBS WATER AND NOT EASY TO CLEAN.
|
|
Recommendation:
Food preparation equipment must be easily cleanable, in good repair, and corrosion-resistant.
|
|
|
Item No.:
39
|
|
Site:
Other-LIDO
|
|
Violation:
THE ARTIFICIAL LIGHTS ABOVE THE BUFFET COUNTERS WERE NOT SHIELDED AGAINST BREAKAGE.
|
|
Recommendation:
Light shields shall be provided for lights where food and equipment are exposed.
|
|
|
Item No.:
21
|
|
Site:
Other-LIDO
|
|
Violation:
THE COUNTERS AT THE COLD TOP AND COOKING AREA AROUND THE OMELETTE STATIONS WERE COVERED WITH TABLE CLOTHS.
|
|
Recommendation:
Nonfood preparation equipment and splash areas must be easily cleanable.
|
|
|
Item No.:
21
|
|
Site:
Other-LIDO
|
|
Violation:
CONTACT PAPER WAS USED TO COVER THE SHELVES IN THE WALK IN COOLER.
|
|
Recommendation:
Nonfood preparation equipment must be easily cleanable, durable, in good repair, and corrosion-resistant.
|
|
|
Item No.:
4
|
|
Site:
Other-LIDO PANTRY
|
|
Violation:
THE JUICE DISPENSER IN THIS ONE AREA WAS NOT EQUIPPED WITH A CONTINUOUS PRESSURE TYPE BACKFLOW PREVENTER.
|
|
Recommendation:
Vacuum breakers and backflow preventers must be properly installed and maintained in good repair at all times to assure reliable operation.
|
|
|
Item No.:
40
|
|
Site:
Other-LIDO SCULLERY
|
|
Violation:
CONDENSATION WAS FORMING ON THE DECKHEAD AND DRIPPING ON TO THE CLEAN SIDE OF THE DISHMACHINE.
|
|
Recommendation:
All warewashing shall have sufficient ventilation to keep them free of excessive heat, steam and condensation.
|
|
|
Item No.:
22
|
|
Site:
Other-MAIN GALLEY - DISHWASHING
|
|
Violation:
THE SCREW PLUG AT THE END OF THE FINAL RINSE MANIFOLD WAS MISSING AND THE FINAL SANITIZING RINSE WATER WAS NOT BEING FORCED THROUGH THE MANIFOLD SPRAY NOZZLES.
[TEMPORARILY CORRECTED AT THE TIME OF THE INSPECTION. PLUMBING SHOP PROVIDED A SIMILAR END CAP.]
|
|
Recommendation:
Spray-type dishwashing machines shall be maintained in good repair. Machines shall be operated in accordance with manufacturers' instructions, and utensils and equipment placed in the machine shall be exposed to all dishwashing cycles.
|
|
|
Item No.:
22
|
|
Site:
Other-MAIN GALLEY - DISHWASHING
|
|
Violation:
SEVERAL FINAL RINSE NOZZLES WERE NOT PROVIDING THE CORRECT SPRAY PATTERN ON THE STARBOARD CONVEYOR TYPE DISHWASHING MACHINE.
|
|
Recommendation:
Spray-type dishwashing machines shall be maintained in good repair. Machines shall be operated in accordance with manufacturers' instructions, and utensils and equipment placed in the machine shall be exposed to all dishwashing cycles.
|
|
|
Item No.:
22
|
|
Site:
Other-MAIN GALLEY - DISHWASHING
|
|
Violation:
THE GLASSWASH MACHINE ON THE PORT SIDE OF THE STARBOARD DISHWASHING AREA WAS PROVIDING ONLY STEAM IN THE FINAL RINSE MANIFOLD. THIS CONDITION HAD ALSO BEEN REPORTED IN THE 01/07/98 USPHS REPORT FOR THE LIDO DISHWASHING MACHINE ON THIS SHIP.
[CORRECTED AT THE TIME OF THE INSPECTION.]
|
|
Recommendation:
Spray-type dishwashing machines shall be maintained in good repair. Machines shall be operated in accordance with manufacturers' instructions, and utensils and equipment placed in the machine shall be exposed to all dishwashing cycles.
|
|
|
Item No.:
22
|
|
Site:
Other-MAIN GALLEY - DISHWASHING
|
|
Violation:
THE TEMPORARY DISH HANDLING TABLES WERE BLOCKING GAUGES ON BOTH CONVEYOR DISHWASHERS PREVENTING ROUTINE MONITORING OF WASH, RINSE AND SANITIZING TEMPERATURES BY STAFF AND SUPERVISORS. DISH WASHING / HANDLING FACILITIES APPEAR TO BE UNDERSIZED OR NOT PROPERLY ORGANIZED IF THESE TABLES ARE NECESSARY TO THE OPERATION.
|
|
Recommendation:
Spray-type dishwashing machines shall be maintained in good repair. Machines shall be operated in accordance with manufacturers' instructions, and utensils and equipment placed in the machine shall be exposed to all dishwashing cycles.
|
|
|
Item No.:
26
|
|
Site:
Other-MAIN GALLEY - DISHWASHING
|
|
Violation:
THE DISHWARE BEING WASHED IN THE PORT CONVEYOR DISHWASHER WAS NOT BEING SANITIZED. THE FINAL RINSE SPRAY WAS NOT ACTIVATING AS THE DISHES PASSED THROUGH THIS PART OF THE MACHINE.
|
|
Recommendation:
Automatic dishwashing machines utilizing hot water for sanitizing shall operate at a minimum of 165F (74°C) measured at dish level.
|
|
|
Item No.:
25
|
|
Site:
Other-MAIN GALLEY - DISHWASHING
|
|
Violation:
THE WASH AND RINSE VAT TEMPERATURES ON THE PORT CONVEYOR TYPE DISHWASHER WERE EACH MEASURED AT 208°F. NORMAL OPERATING RANGE FOR THESE PARTS OF THE DISHWASHING CYCLE ARE BETWEEN 140°F AND 160°F FOR THESE MACHINES. CHECK MACHINE MANUFACTURER'S INSTRUCTIONS FOR SPECIFIC OPERATIONAL PARAMETERS FOR THE INSTALLED DISHMACHINES.
|
|
Recommendation:
Spray-type dishwashing machines shall be operated in accordance with manufacturers' instructions.
|
|
|
Item No.:
22
|
|
Site:
Other-MAIN GALLEY - DISHWASHING
|
|
Violation:
THE GLASSWASH MACHINE IN THE PORT SIDE DISHWASHING AREA ALSO HAD STEAM RATHER THAN HOT SANITIZING WATER BEING PRODUCED IN THE FINAL RINSE CYCLE.
|
|
Recommendation:
Spray-type dishwashing machines shall be maintained in good repair. Machines shall be operated in accordance with manufacturers' instructions, and utensils and equipment placed in the machine shall be exposed to all dishwashing cycles.
|
|
|
Item No.:
28
|
|
Site:
Other-MAIN GALLEY - HOT GALLEY SOUP STATION
|
|
Violation:
THE INTERIOR FOOD CONTACT SURFACES ON THREE TILTING KETTLES HAD FOOD RESIDUE ON THEM AFTER THEY WERE CLEANED.
|
|
Recommendation:
Food contact surfaces of equipment shall be thoroughly washed, rinsed and sanitized after each use and prior to storage.
|
|
|
Item No.:
7
|
|
Site:
Other-MAIN GALLEY - HOT GALLEY SOUP STATION
|
|
Violation:
THE DRAIN HOLES IN THE PEDESTALS FOR THE TILTING KETTLES AND SKILLETS WERE HEAVILY SOILED.
|
|
Recommendation:
Wastewater from equipment and sinks must be properly drained to prevent pooling or leaking of water on the deck. Drains should be maintained clean and in good repair.
|
|
|
Item No.:
38
|
|
Site:
Other-MAIN GALLEY - HOT GALLEY SOUP STATION
|
|
Violation:
THE WALK IN COOLER (#3) HAD GROUT RECESSING IN THE DECK NEAR THE DOOR.
|
|
Recommendation:
Decks, bulkheads, and deckheads in food preparation, warewashing, and storage areas, including pantries, shall be designed and constructed for easy cleanability, shall be corrosion-resistant, maintained in good repair, and kept clean.
|
|
|
Item No.:
38
|
|
Site:
Other-FOOD SERVICE GENERAL
|
|
Violation:
THE BULKHEADS AND BULKHEAD / DECK COMBING JUNCTURES WERE NOT TIGHT CREATING DIFFICULT TO CLEAN SEAMS AND GAPS.
|
|
Recommendation:
Bulkheads and deckheads, including doors, windows, skylights and similar closures, shall be maintained in good repair.
|
|
|
Item No.:
21
|
|
Site:
Other-FOOD SERVICE GENERAL
|
|
Violation:
THE PROFILE STRIPS AT BULKHEAD / EQUIPMENT JUNCTURES WERE LOOSE IN THE KETTLE AREA, TILTING SKILLETS AND SEVERAL OTHER LOCATIONS THROUGH OUT THE GALLEY.
|
|
Recommendation:
Nonfood preparation equipment must be easily cleanable, in good repair, and corrosion-resistant.
|
|
|
Item No.:
21
|
|
Site:
Other-FOOD SERVICE GENERAL
|
|
Violation:
LONG ELECTRICAL CORDS WERE NOTED ON A NUMBER OF PIECES OF COUNTER MOUNTED EQUIPMENT MAKING IT DIFFICULT TO CLEAN AROUND THE EQUIPMENT.
|
|
Recommendation:
Utility connections should be short enough to facilitate cleaning around equipment.
|
|
|
Item No.:
36
|
|
Site:
Other-FOOD SERVICE GENERAL
|
|
Violation:
NUMEROUS FLIES WERE NOTED IN THE MAIN GALLEY AND IN THE PROVISIONS AREA OF THE SHIP. THE NUMBER OF FLIES INCREASED DURING THE INSPECTION AS THE SHIP WAS REPROVISIONING. THIS INDICATED THAT CURRENT FLY CONTROL MEASURES MAY NOT BE EFFECTIVE.
|
|
Recommendation:
Effective measures intended to minimize the presence of rodents, flies, cockroaches, and other insects on the premises shall be utilized.
|
|
|
Item No.:
20
|
|
Site:
Other-MAIN GALLEY - COLD GALLEY / ROOM SERVICE
|
|
Violation:
THE VEGETABLE JUICER MACHINE HAD A FOOD CONTACT SURFACE COATING THAT WAS IN POOR REPAIR AND FLAKING OFF.
|
|
Recommendation:
Food-contact and ice-contact surfaces must be constructed of materials that are nontoxic, smooth, corrosion-resistant, nonabsorbent, and durable under conditions of normal use.
|
|
|
Item No.:
20
|
|
Site:
Other-MAIN GALLEY - COLD GALLEY / ROOM SERVICE
|
|
Violation:
THE CRUSHED ICE MACHINE STORAGE BIN WAS OPEN ON TOP EXPOSING THE ICE TO A DIFFICULT TO CLEAN AREA.
|
|
Recommendation:
Food-contact surfaces also must be easily cleanable and free of difficult-to-clean internal corners, crevices, and fasteners.
|
|
|
Item No.:
28
|
|
Site:
Other-MAIN GALLEY - BEVERAGE STATIONS
|
|
Violation:
THE CAPPUCCINO MACHINES HAD PLASTIC MILK STEAMER PARTS THAT WERE HEAVILY SOILED WITH OLD MILK RESIDUE.
|
|
Recommendation:
Food contact surfaces of equipment shall be thoroughly washed, rinsed and sanitized after each use and prior to storage.
|
|
|
Item No.:
28
|
|
Site:
Other-MAIN GALLEY - BEVERAGE STATIONS
|
|
Violation:
THE STARBOARD CAPPUCCINO MACHINE HAD A MILK CONTAINER THAT HAD NOT BEEN THOROUGHLY CLEANED FOR A LONG PERIOD OF TIME. THE INTERIOR OF THE CONTAINER WAS HEAVILY SOILED WITH A THICK LAYER OF OLD MILK RESIDUE.
|
|
Recommendation:
Food contact surfaces of equipment shall be thoroughly washed, rinsed and sanitized after each use and prior to storage.
|
|
|
Item No.:
14
|
|
Site:
Other-PROVISIONS
|
|
Violation:
HEAVY FROST AND FROZEN CONDENSATION WAS NOTED ON MANY CARTONS OF FOOD IN THE FROZEN VEGETABLE STORES. SOME ITEMS APPEARED TO HAVE HELD FOR A LONG PERIOD OF TIME BY THE DETERIORATING CONDITION OF THE CONTAINERS.
|
|
Recommendation:
During transportation and storage, food shall be protected from contamination.
|
|
|
Item No.:
7
|
|
Site:
Other-PROVISIONS
|
|
Violation:
AN EVAPORATOR DRAIN LINE IN THE DRY STORES WAS BROKEN.
|
|
Recommendation:
Wastewater from equipment and sinks must be properly drained to prevent pooling or leaking of water on the deck.
|
|
|
Item No.:
9
|
|
Site:
Other-LIDO
|
|
Violation:
A ONE QUART MILK CONTAINER WAS OPEN AND PARTIALLY FULL IN THE UNDER COUNTER REACH IN COOLER.
|
|
Recommendation:
Milk and milk products for drinking shall be provided to the consumer in an unopened, commercially filled package not exceeding 1-pint in capacity, or drawn from a commercially filled container stored in a mechanically refrigerated bulk milk dispenser. When milk is not available in a package containing 1-pint or less, i.e., milk obtained from a country other than the U.S.A., then opened containers of milk will be discarded following the serving period.
|
|
|
Item No.:
26
|
|
Site:
Other-MAIN GALLEY - DISHWASHING
|
|
Violation:
THE STARBOARD CONVEYOR TYPE DISHWASHING MACHINE WAS NOT PROVIDING ANY SANITIZING SPRAY TO DISHES DURING ITS ROUTINE OPERATION.
|
|
Recommendation:
Automatic dishwashing machines utilizing hot water for sanitizing shall operate at a minimum of 165°F (74°C) measured at dish level.
|
|
|
Item No.:
22
|
|
Site:
Other-MAIN GALLEY - DISHWASHING
|
|
Violation:
THE FINAL RINSE SOLENOID VALVE IN THE PORT CONVEYOR TYPE DISHWASHER WAS BROKEN.
|
|
Recommendation:
Spray-type dishwashing machines shall be maintained in good repair. Machines shall be operated in accordance with manufacturers' instructions, and utensils and equipment placed in the machine shall be exposed to all dishwashing cycles.
|
|