Cruise Ship: Silver Wind Cruise Line: Silversea Inspection Date: 03/27/1999 Inspection Score: 96
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 11
Site: Other-CREW MESS
Violation: Cartons of milk that require refrigeration only after opening were poured into a chilled liquid dispenser. The temperature of the milk was 47oF.
Recommendation: Cartons of milk shall be pre-chilled prior to putting the product into the chilled liquid dispenser.
Item No.: 20
Site: Other-HOT GALLEY
Violation: There were non-easily cleanable knife cuts in the plastic cutting boards.
Recommendation: Food-contact and ice-contact surfaces must be constructed of materials that are nontoxic, smooth, corrosion-resistant, nonabsorbent, and durable under conditions of normal use. Food-contact surfaces also must be easily cleanable and free of difficult-to-clean internal corners, cuts, crevices, and fasteners.
Item No.: 22
Site: Other-LIDO POT WASH
Violation: Cold water was used in the wash sink.
Recommendation: The manual wash temperature shall be between 90oF and 110oF.
Item No.: 22
Site: Other-LIDO SCULLERY
Violation: The final rinse temperature of the dishwashing machine was measured at 185oF at the dish surface.
Recommendation: The temperature at dish level only needs to be 165oF. To high of a temperature may result in steam emitting from the final rinse spray nozzles.
Item No.: 26
Site: Other-POTWASH
Violation: The chlorine concentration in the final rinse sink was only 10 ppm.
Recommendation: The chlorine concentration shall be at least 50 ppm.
Item No.: 28
Site: Other-OFFICERS` MESS
Violation: The plastic dispensing tube on the juice machine was soiled with dried juice residue.
Recommendation: All food preparation equipment, utensils, tableware, other food contact surfaces and food storage containers shall be washed, rinsed, and sanitized after every use or change in use. A food surface is that surface of equipment or utensil with which food normally comes in contact and those surfaces from which food may drip, drain, or splash back onto other surfaces normally in contact with food.
Item No.: 30
Site: Other-DINING ROOM-WAITER STATIONS
Violation: The silverware was stored randomly in drawers at the waiter stations. The waiters had to handle the food contact surfaces when setting the tables.
Recommendation: Spoons, knives, and forks shall be touched only by their handles.
Item No.: 30
Site: Other-MAIN GALLEY
Violation: There was no physical separation between the drinking fountain and the clean storage rack adjacent to it.
Recommendation: Cleaned and sanitized utensils and equipment shall be stored at least 6-inches above the floor in a clean, dry location in a way that protects them from contamination by splash, dust, and other means.
Item No.: 38
Site: Other-HOT GALLEY
Violation: There was black mold on the deck below the tilting pan.
Recommendation: Decks, bulkheads, and deckheads in food preparation, warewashing, and storage areas, including pantries, shall be designed and constructed for easy cleanability, shall be corrosion-resistant, maintained in good repair, and kept clean.
Item No.: 38
Site: Other-FOOD SERVICE-GENERAL
Violation: Deck tile grouting was recessed or missing in several areas.
Recommendation: Decks, bulkheads, and deckheads in food preparation, warewashing, and storage areas, including pantries, shall be designed and constructed for easy cleanability, shall be corrosion-resistant, maintained in good repair, and kept clean.