Item No.:
40
|
|
Site:
Other-GALLEY
|
|
Violation:
Condensation was present on the bulkheads, deckheads and in the cabinets by the dishwashing machine.
|
|
Recommendation:
Ventilation systems shall be adequately designed to remove a large percentage of the hot humid air in food service areas to prevent workers from perspiring profusely and to prevent the accumulation of condensation on bulkheads and deckheads.
|
|
|
Item No.:
38
|
|
Site:
Other-GALLEY
|
|
Violation:
There were open seams in the deckhead.
|
|
Recommendation:
Bulkheads and deckheads in food preparation, warewashing, and storage areas, shall be designed and constructed for easy cleanability, shall be corrosion-resistant, maintained in good repair and kept clean.
|
|
|
Item No.:
28
|
|
Site:
Other-GALLEY
|
|
Violation:
Food residues were present on clean serving utensils and pans.
|
|
Recommendation:
To prevent cross-contamination, pots, pans, utensils and other food contact surfaces of equipment shall be thoroughly washed, rinsed and sanitized after each use and prior to storage. Any items which are found to be soiled after being washed, must be returned to the warewashing area for immediate re-washing.
|
|
|
Item No.:
21
|
|
Site:
Other-GALLEY
|
|
Violation:
Replace cardboard plastic wrap and aluminum foil dispensers with stainless steel or durable food grade plastic dispensers that are easily cleanable.
|
|
Recommendation:
|
|
|
Item No.:
21
|
|
Site:
Other-GALLEY
|
|
Violation:
There was an open seam between the stove and counter.
|
|
Recommendation:
Unless sufficient space is provided for easy cleaning between, behind and above each unit of fixed equipment, the space between it and adjoining equipment and adjacent bulkheads or deckheads shall be not more than 1/32-inch. If exposed to seepage, the equipment shall be sealed to the adjoining equipment or adjacent bulkheads or deckheads.
|
|
|
Item No.:
22
|
|
Site:
Other-GALLEY
|
|
Violation:
The upper sanitizing rinse arm in the warewashing machine was not rotating freely.
|
|
Recommendation:
Warewashing machines shall be properly installed and maintained in good repair. Machines shall be inspected daily and operated in accordance with manufacturers' instructions.
|
|
|
Item No.:
20
|
|
Site:
Other-GALLEY
|
|
Violation:
The interior of the microwave oven was missing a fastener.
|
|
Recommendation:
Replace the missing fastener. The interiors of microwave ovens are considered food-contact surfaces and must be constructed accordingly.
|
|
|
Item No.:
14
|
|
Site:
Other-GALLEY
|
|
Violation:
There was no air break in the drain line from the warewashing/food preparation sinks and warewashing machine.
|
|
Recommendation:
Drain lines from all fixtures, appliances, compartments, refrigeration units or devices that are used, designed for, or intended to be used in the preparation, processing, storage or handling of food, ice or drinks shall be indirectly connected to appropriate waste systems by means of an air gap or air break.
|
|
|
Item No.:
4
|
|
Site:
Other-GALLEY
|
|
Violation:
The backflow preventer was leaking on the pre-wash spray hose at the warewashing machine.
|
|
Recommendation:
Vacuum breakers and backflow preventers must be properly installed and maintained in good repair at all times to assure reliable operation.
|
|
|
Item No.:
22
|
|
Site:
Other-GALLEY
|
|
Violation:
Clean dishware from the warewashing machine was placed on a cloth towel. A cloth towel was also hung next to the warewashing machine.
|
|
Recommendation:
All washed dishware and utensils shall be allowed to drain and air dry without the use of drying cloths. Pots and other containers must be put in a self-draining position to permit air drying.
|
|
|
Item No.:
14
|
|
Site:
Other-GALLEY
|
|
Violation:
Insufficient counter space was provided to separate clean and soiled operations.
|
|
Recommendation:
To prevent cross-contamination, separate facilities, sufficient space and/or physical barriers shall be provided to separate clean and soiled operations that occur at the same time. Additionally, there shall be operational procedures to wash, rinse and sanitize between soiled and clean operations utilizing the same equipment.
|
|
|
Item No.:
34
|
|
Site:
Other-GALLEY
|
|
Violation:
Accessibility to the handwashing sink was partially blocked by soiled dishware.
|
|
Recommendation:
Handwashing sinks must be accessible to employees at all times.
|
|
|
Item No.:
14
|
|
Site:
Other-GALLEY
|
|
Violation:
The same sinks for warewashing were used for food preparation.
|
|
Recommendation:
To prevent cross-contamination, avoid the use of the same sinks for warewashing and food preparation. Ensure that sinks are washed, rinsed and sanitized between operations.
|
|
|
Item No.:
37
|
|
Site:
Other-GALLEY
|
|
Violation:
An unlabeled spray bottle of bleach solution was stored under the sinks.
|
|
Recommendation:
All spray bottles shall be properly labeled identifying their contents.
|
|
|
Item No.:
19
|
|
Site:
Other-GALLEY
|
|
Violation:
An employee operating the warewashing machine was not washing their hands between re-gloving with disposable gloves.
|
|
Recommendation:
It is required that food service employees wash their hands after removing soiled gloves prior to re-gloving with clean gloves.
|
|
|
Item No.:
19
|
|
Site:
Other-GALLEY
|
|
Violation:
A waitress did not wash her hands between scraping soiled dishes and serving food.
|
|
Recommendation:
After handling soiled dishware or utensils, employees must wash their hands again before handling clean dishes and utensils or serving food.
|
|
|
Item No.:
9
|
|
Site:
Other-PROVISIONS
|
|
Violation:
Milk from gallon containers was dispensed into pitchers for passenger consumption.
|
|
Recommendation:
Milk and milk products for drinking shall be provided to the consumer in an unopened, commercially filled package not exceeding 1-pint in capacity, or drawn from a commercially filled container stored in a mechanically refrigerated bulk milk dispenser. When milk is not available in a package containing 1-pint or less, i.e., milk obtained from a country other than the U.S.A., then opened containers of milk will be discarded following the serving period.
|
|
|
Item No.:
39
|
|
Site:
Other-BAR
|
|
Violation:
There was less than 20 foot candles of light over the sink.
|
|
Recommendation:
It is required that additional lighting be provided to insure at least 20 foot candles of light over the sink.
|
|
|
Item No.:
14
|
|
Site:
Other-BAR
|
|
Violation:
There was no air break on the drain from the ice sink.
|
|
Recommendation:
Drain lines from all fixtures, appliances, compartments, refrigeration units or devices that are used, designed for, or intended to be used in the preparation, processing, storage or handling of food, ice or drinks shall be indirectly connected to appropriate waste systems by means of an air gap or air break.
|
|
|
Item No.:
27
|
|
Site:
Other-GALLEY
|
|
Violation:
There was more than 200 ppm of chlorine in the sanitizing buckets for wiping cloths.
|
|
Recommendation:
Moist cloths or sponges used for wiping food contact surfaces of equipment shall be clean and must be rinsed frequently in a sanitizing solution between 50-100 ppm.
|
|
|
Item No.:
39
|
|
Site:
Other-GALLEY
|
|
Violation:
Many of the lights in the refrigerators were inoperative and it was difficult to see in the refrigerators to clean.
|
|
Recommendation:
It is required that lighting be provided to insure there is at least 10 foot candles of light in all refrigerators.
|
|
|
Item No.:
2
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
There were several short periods of time from 4 to 20 hours when there was no chlorine recorded on the chart recorder for the distribution system.
|
|
Recommendation:
The potable water distribution system must contain at least 0.2 ppm but must not exceed 5.0 ppm free chlorine or bromine residual. A review of records from the ship's automatic chlorine or bromine analyzer must show that the ship has maintained adequate amounts of free halogen residual in the water distribution system since the last inspection of the vessel. The review will be deemed unacceptable if the records show a free halogen residual of less than 0.2 ppm for more than 24 consecutive hours. Charts shall be initialed and dated daily and retained for at least 12-months.
|
|