Item No.:
11
|
|
Site:
Other-VERANDA
|
|
Violation:
A LARGE BOWL OF YOGURT ON THE BUFFET COLD TOP HAD AN INTERNAL PRODUCT TEMPERATURE OF 50 °F. SUGGEST SURROUNDING THIS BOWL WITH AN ICE BATH IN THE FUTURE TO IMPROVE COLD TRANSFER.
|
|
Recommendation:
Please refer to the recommendation listed under Item 1.
|
|
|
Item No.:
26
|
|
Site:
Other-GRANDEUR BLUE
|
|
Violation:
THE POT WASHING SINKS WERE FULL OF WATER FROM USAGE EARLIER IN THE MORNING. THE SANITIZING SINK HAD NO CHLORINE RESIDUAL AND HAD A TEMPERATURE OF 120 °F. NO POTS/PANS WERE BEING WASHED AT THE TIME OF INSPECTION, BUT THE SINKS WERE FILLED AND READY FOR USE.
|
|
Recommendation:
Ensure the sanitizing rinse sink has a minimum 50 ppm chlorine solution when standing full if chlorine is to be used for sanitization.
|
|
|
Item No.:
30
|
|
Site:
Other-GRANDEUR BLUE
|
|
Violation:
FOUR DISHWARE RACKS WERE STORED ON THE DECK AT THE CONVEYOR DISHWASH MACHINE.
|
|
Recommendation:
Adequate space and shelving shall be provided for the storage of clean utensils and equipment and shall be located and designed to prevent contamination.
|
|
|
Item No.:
21
|
|
Site:
Other-BARS - GENERAL
|
|
Violation:
THE TECHNICAL SPACE ON THE UNDERSIDE OF THE CAPPUCCINO MACHINES WAS EXPOSED, AS THE COVER PLATE WAS MISSING. RECOMMEND INSTALLING A COVER PLATE ON THE MACHINES SO THEY CAN BE PROPERLY CLEANED.
|
|
Recommendation:
Nonfood preparation equipment must be easily cleanable, in good repair, and corrosion-resistant.
|
|
|
Item No.:
18
|
|
Site:
Other-MEDICAL - REPORTING
|
|
Violation:
ALTHOUGH THE 24 HOUR PRIOR TO ARRIVAL DIARRHEAL ILLNESS NOTIFICATION WAS RECORDED, IT WAS NOT FORWARDED TO THE CDC VESSEL SANITATION PROGRAM OFFICE AS REQUIRED. NO PRIOR TO ARRIVAL REPORT WAS RECEIVED FOR THE CURRENT CRUISE OR THE PREVIOUS CRUISE (PRIOR TO ST. THOMAS).
|
|
Recommendation:
Diarrhea logs in the hospital must be accurately maintained, and results must be reported to the Vessel Sanitation Program in accordance with Section III of the "Vessel Sanitation Program Operations Manual", August 1989.
|
|
|
Item No.:
12
|
|
Site:
Other-GALLEY D
|
|
Violation:
ONE OF THE THREE FOOD PROBE THERMOMETERS TESTED WAS OUT OF CALIBRATION BY 20 °F.
|
|
Recommendation:
All thermometers shall be accurate to +2oF (+1oC).
|
|
|
Item No.:
22
|
|
Site:
Other-GALLEY D
|
|
Violation:
PRESSURE GAUGES ON THE DISHWASH MACHINES WERE NOT FUNCTIONING. THE GAUGES REGISTERED 40 PSI CONTINUOUSLY, WHILE THE MACHINE DATA PLATES SPECIFIED A RANGE OF 20 PSI PLUS OR MINUS 5 PSI.
|
|
Recommendation:
Dishes and utensils must be cleaned and sanitized utilizing spray-type dishwashing machines. These machines shall be properly installed and maintained in good repair. Machines shall be operated in accordance with manufacturers' instructions, and utensils and equipment placed in the machine shall be exposed to all dishwashing cycles. All automatic detergent dispensers, wetting agent dispensers, and liquid sanitizer injectors shall be properly installed and maintained.
|
|
|
Item No.:
38
|
|
Site:
Other-GALLEY E
|
|
Violation:
SEAM SEALANT ALONG BULKHEAD PANELS WAS PEELING OVER THE FOOD PREPARATION AREA.
|
|
Recommendation:
Decks, bulkheads, and deckheads in food preparation, warewashing, and storage areas, including pantries, shall be designed and constructed for easy cleanability, shall be corrosion-resistant, maintained in good repair, and kept clean.
|
|
|
Item No.:
26
|
|
Site:
Other-GALLEY E - DISHWASHING
|
|
Violation:
THE DISHWASH MACHINE HAD A FINAL SPRAY RINSE TEMPERATURE OF 150 °F. THE MACHINE WAS NOT IN USE AT THE TIME OF INSPECTION, BUT HAD BEEN OPERATING 45 MINUTES PRIOR.
|
|
Recommendation:
Automatic dishwashing machines utilizing hot water for sanitizing shall operate at a minimum of 165oF (74oC) measured at dish level.
|
|
|
Item No.:
38
|
|
Site:
Other-PROVISIONS
|
|
Violation:
THE LIGHT FIXTURE WAS DETACHED FROM THE DECKHEAD IN THE FISH WALK-IN.
|
|
Recommendation:
Repair or replace the light fixture.
|
|
|
Item No.:
38
|
|
Site:
Other-PROVISIONS
|
|
Violation:
THE DECK SURROUNDING AND BENEATH THE PALLETS IN THE FISH WALK-IN WERE SOILED WITH DIRT RESIDUE AND VARIOUS FOOD DEBRIS. THE UNIT WAS OVER FULL MAKING CLEANING THE DECK DIFFICULT.
|
|
Recommendation:
Decks, bulkheads, and deckheads in food preparation, warewashing, and storage areas, including pantries, shall be designed and constructed for easy cleanability, shall be corrosion-resistant, maintained in good repair, and kept clean.
|
|