Item No.:
40
|
|
Site:
Other-GALLEY DECK 3
|
|
Violation:
EXCESSIVE CONDENSATION WAS PRESENT ON THE DECKHEAD SURROUNDING THE FLIGHT-TYPE CONVEYOR DISHWASH MACHINE. WATER WAS DRIPPING FROM THE DECKHEAD TO SURFACES BELOW.
|
|
Recommendation:
All food preparation, warewashing and toilet rooms shall have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke and fumes.
|
|
|
Item No.:
28
|
|
Site:
Other-GALLEY DECK 3 - POT WASH
|
|
Violation:
A FEW OF THE PREVIOUSLY CLEANED PANS AND CUTTING BOARDS WERE FOUND SOILED WITH FOOD DEBRIS ON THE CLEAN STORAGE RACK.
|
|
Recommendation:
To prevent cross-contamination, pots, pans, utensils and other food contact surfaces of equipment shall be thoroughly washed, rinsed and sanitized after each use and prior to storage. Any items which are found to be soiled after being washed, must be returned to the warewashing area for immediate re-washing.
|
|
|
Item No.:
22
|
|
Site:
Other-GALLEY DECK 4
|
|
Violation:
THE UPPER SPRAY NOZZLES IN THE FINAL RINSE COMPARTMENT OF THE GLASSWASH MACHINE WERE PARTIALLY CLOGGED, PRODUCING A WEAK SPRAY PATTERN. THE SPRAY ARM WAS LATER REMOVED AND FLUSHED TO CORRECT THE PROBLEM.
|
|
Recommendation:
Dishes and utensils must be cleaned and sanitized utilizing spray-type dishwashing machines. These machines shall be properly installed and maintained in good repair. Machines shall be operated in accordance with manufacturers' instructions, and utensils and equipment placed in the machine shall be exposed to all dishwashing cycles. All automatic detergent dispensers, wetting agent dispensers, and liquid sanitizer injectors shall be properly installed and maintained.
|
|
|
Item No.:
26
|
|
Site:
Other-GALLEY DECK 4 - POT WASH
|
|
Violation:
THE WATER TEMPERATURE IN THE SANITIZING SINK WAS 152 °F DURING USE.
|
|
Recommendation:
Hot water sanitization must be at a minimum of 170 °F in the three compartment sink.
|
|
|
Item No.:
23
|
|
Site:
Other-GALLEY DECK 4 - POT WASH
|
|
Violation:
THE THERMOMETER ON THE HOT WATER SANITIZING RINSE SINK REGISTERED 100 °F WHEN THE WATER TEMPERATURE WAS 152 °F ON THE MANUAL TEST.
|
|
Recommendation:
Machine or water line-mounted, numerically scaled, indicating thermometers, accurate to +3oF (+1.5oC), shall be provided to indicate the temperature of the water in each tank of the machine and the temperature of the final rinse water as it enters the manifold.
|
|
|
Item No.:
30
|
|
Site:
Other-GALLEY DECK 4
|
|
Violation:
FOUR OVEN RACKS WERE STORED ON THE DECK BESIDE THE COOK AND HOLD REACH-IN OVEN BANK.
|
|
Recommendation:
Oven racks should be stored in the unit or on a shelf or stand, protected from potential contamination.
|
|
|
Item No.:
28
|
|
Site:
Other-GALLEY DECK 5
|
|
Violation:
THE UPPER INTERIOR OF ICE CUBER MACHINE 5-6 HAD SLIME MOLD ON THE CUBE CHUTE COVER AND NEAR THE CHUTE ENTRANCE.
|
|
Recommendation:
Review the cleaning frequency and methods for such units and determine if more can be done to maintain them in a sanitary manner.
|
|
|
Item No.:
4
|
|
Site:
Other-GALLEY DECK 5
|
|
Violation:
THE BACKFLOW PREVENTER ABOVE THE COFFEE MACHINE AT THE BEVERAGE STATION WAS LEAKING CONTINUOUSLY.
|
|
Recommendation:
Vacuum breakers and backflow preventers must be properly installed and maintained in good repair at all times to assure reliable operation.
|
|
|
Item No.:
39
|
|
Site:
Other-OFFICER'S MESS
|
|
Violation:
ARTIFICIAL LIGHT LEVELS ALONG THE BEVERAGE STATION AND THE CEREAL CUPBOARD/COUNTER WERE BELOW 20 FOOT CANDLES (220 LUX).
|
|
Recommendation:
It is required that additional lighting be provided to insure at least 20-footcandles of light on all food preparation surfaces during cleaning periods.
|
|
|
Item No.:
29
|
|
Site:
Other-OFFICER'S MESS
|
|
Violation:
THE COUNTERTOP BENEATH/BEHIND THE EQUIPMENT ALONG THE BEVERAGE STATION WAS SOILED WITH DUST.
|
|
Recommendation:
Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
|
|
|
Item No.:
29
|
|
Site:
Other-CAFÉ PROMENADE
|
|
Violation:
THE TOP EXTERIOR SURFACE OF THE COFFEE MACHINE AT THE BEVERAGE STATION WAS SOILED WITH DUST AND COFFEE DEBRIS.
|
|
Recommendation:
Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
|
|
|
Item No.:
28
|
|
Site:
Other-CHAMPAGNE BAR
|
|
Violation:
THE UPPER INTERIOR OF ICE CUBER MACHINE 5-5 HAD MOLD RESIDUE ON INTERIOR SURFACES OF THE CUBER FLAP AND ALONG THE CHUTE BASE.
|
|
Recommendation:
Examine the cleaning frequency and method for such units to determine if the service is frequent and thorough enough to maintain the units in a sanitary manner.
|
|
|
Item No.:
29
|
|
Site:
Other-WINDJAMMER
|
|
Violation:
THE EXTERIOR NON-FOOD CONTACT SURFACES OF THE WAFFLE IRONS WERE SOILED WITH FOOD RESIDUE ON THE SERVICE LINE.
|
|
Recommendation:
Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
|
|
|
Item No.:
34
|
|
Site:
Other-WINDJAMMER - CLEAN DISH STORAGE
|
|
Violation:
AN ELECTRIC FLOOR CLEANER WAS STORED IN FRONT OF THE HANDWASH SINK AT THE CLEAN DISH AREA, BLOCKING ACCESS TO THE SINK.
|
|
Recommendation:
Handwashing sinks must be accessible to employees at all times.
|
|
|
Item No.:
35
|
|
Site:
Other-WINDJAMMER - CLEAN DISH STORAGE
|
|
Violation:
A PAPER TOWEL WASTE RECEPTACLE WAS NOT PROVIDED AT THE HANDWASH STATION IN THIS AREA.
|
|
Recommendation:
It is required that easily cleanable waste receptacles be provided for each handwashing station.
|
|
|
Item No.:
40
|
|
Site:
Other-WINDJAMMER - DISH/GLASS WASH AREAS
|
|
Violation:
CONDENSATION WAS NOTED ON THE DECKHEAD ATTACHED AIR CONDITIONING SUPPLY VENT OVER THE CLEAN RAMP AT THE GLASSWASH MACHINE. CONDENSATION WAS ALSO NOTED DRIPPING DOWN FROM THE VENT AND FROM THE OUTER EDGES OF THE GLASSWASH VENTILATION HOOD.
|
|
Recommendation:
All food preparation, warewashing and toilet rooms shall have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke and fumes.
|
|
|
Item No.:
22
|
|
Site:
Other-WINDJAMMER - DISHWASH
|
|
Violation:
SEVERAL OF THE RINSE NOZZLES JUST PRIOR TO THE FINAL RINSE SPRAY WERE BLOCKED IN THE DISHWASH MACHINE, RESULTING IN A POOR SPRAY PATTERN.
|
|
Recommendation:
Dishes and utensils must be cleaned and sanitized utilizing spray-type dishwashing machines. These machines shall be properly installed and maintained in good repair. Machines shall be operated in accordance with manufacturers' instructions, and utensils and equipment placed in the machine shall be exposed to all dishwashing cycles. All automatic detergent dispensers, wetting agent dispensers, and liquid sanitizer injectors shall be properly installed and maintained.
|
|
|
Item No.:
22
|
|
Site:
Other-WINDJAMMER - DISHWASH
|
|
Violation:
THERE WAS AN EXCESSIVE AMOUNT OF FOOD DEBRIS NOTED IN THE PRE-WASH AND WASH COMPARTMENTS OF THE DISHWASH MACHINE. FOOD DEBRIS WAS ALSO NOTED IN THE RINSE AND FINAL RINSE COMPARTMENTS. THE CREW STATED THAT DUE TO THE SHORT SERVICE TIME (1.5 HOURS) THE DISHWASHER WAS NOT DRAINED AND CLEANED.
|
|
Recommendation:
The pre-scrapping of food waste and other debris should be improved prior to placing dishware into the machine, and the machine should be drained and cleaned based solely on the accumulation of dirt and debris accumulating in the compartments, not the service time period.
|
|
|
Item No.:
22
|
|
Site:
Other-WINDJAMMER - GLASSWASH
|
|
Violation:
THE RIGHT SIDE UPPER FINAL SPRAY RINSE NOZZLE IN THE GLASSWASH MACHINE DID NOT PROVIDE AN EFFECTIVE SPRAY PATTERN OVER THE GLASSES IN THE DISHRACKS. THIS ITEM WAS CORRECTED DURING THE INSPECTION.
|
|
Recommendation:
Dishes and utensils must be cleaned and sanitized utilizing spray-type dishwashing machines. These machines shall be properly installed and maintained in good repair. Machines shall be operated in accordance with manufacturers' instructions, and utensils and equipment placed in the machine shall be exposed to all dishwashing cycles. All automatic detergent dispensers, wetting agent dispensers, and liquid sanitizer injectors shall be properly installed and maintained.
|
|
|
Item No.:
30
|
|
Site:
Other-WINDJAMMER - GLASSWASH
|
|
Violation:
CLEAN DISHES WERE STACKED ON THE CLEAN STAGING TABLE SUCH THAT THEY EXTENDED BEYOND THE TABLE EDGE, SUBJECTING THEM TO CONTAMINATION FROM STAFF PASSING THRU THE AREA.
|
|
Recommendation:
Adequate space and shelving shall be provided for the storage of clean utensils and equipment and shall be located and designed to prevent contamination.
|
|
|
Item No.:
21
|
|
Site:
Other-JOHNNY ROCKETS - SERVICE AREA
|
|
Violation:
PEELING/CHIPPING STAINLESS STEEL PLATING WAS NOTED IN THE GRILL DRIP PAN HOUSING.
|
|
Recommendation:
Nonfood preparation equipment must be easily cleanable, in good repair, and corrosion-resistant.
|
|
|
Item No.:
21
|
|
Site:
Other-JOHNNY ROCKETS - SERVICE AREA
|
|
Violation:
PEELING/LOOSE SOFT SEALANT WAS NOTED IN THE GRILL DRIP PAN HOUSINGS. THE SEALANT WAS APPLIED EXCESSIVELY. THIS SEALANT WAS ALSO PEELING ON THE EXTERIOR SURFACES OF THE GRILLS.
|
|
Recommendation:
Recommend removal of all peeling or loose sealant, evaluating the need for sealant in the areas applied (seams greater than 1/32nd inch and less than 1/8th), re-application only to those seams which meet the above criteria, and use of an appropriate amount which leaves a smooth cove.
|
|
|
Item No.:
5
|
|
Site:
Other-POTABLE WATER SYSTEM
|
|
Violation:
THE BUNKER MANIFOLD CAPS AT THE BUNKER STATION WERE NOT ATTACHED WITH CHAINS TO PREVENT MISHANDLING AND POTENTIAL CONTAMINATION.
|
|
Recommendation:
Potable water hoses must be flushed before the filling line is attached. Hoses must be drained after each use and stowed, with ends capped, on reels or racks in special lockers marked "POTABLE WATER HOSE AND FITTINGS STORAGE" in letters at least one-half inch high. Lockers must be closed self-draining, smooth, nontoxic, corrosion-resistant, easily cleanable, fixed 18-inches above the deck and used for no other purpose. Hoses and fittings must be maintained in good repair.
|
|
|
Item No.:
34
|
|
Site:
Other-POTABLE WATER SYSTEM
|
|
Violation:
THE SERVICE LOCKER 3739, WHERE THE LOWER LOOP POTABLE WATER ANALYZER IS LOCATED, HAD A TRAY OF DIRTY DISHES STORED ON THE DECK, AND THE HANDWASH SINK HAD BEEN USED TO DUMP ICE AND FOOD SCRAPS.
|
|
Recommendation:
Handwashing facilities must be used for no other purpose and must be accessible at all times, kept clean and be in good repair.
|
|
|
Item No.:
4
|
|
Site:
Other-POTABLE WATER SYSTEM - BACKFLOW
|
|
Violation:
CHECK ALL REDUCED PRESSURE PRINCIPLE (RP) BACKFLOW PREVENTER DRAINS TO ENSURE THAT ANY LEAKAGE IS CLEARLY VISIBLE. AT LEAST ONE RP DRAIN IN THE WHIRLPOOL MECHANICAL ROOM WAS ROUTED BEHIND THE BUFFER TANK AND CONNECTED TO A WASTE DRAIN FROM ANOTHER PIECE OF EQUIPMENT.
|
|
Recommendation:
Vacuum breakers and backflow preventers must be properly installed and maintained in good repair at all times to assure reliable operation.
|
|
|
Item No.:
40
|
|
Site:
Other-CREW GALLEY - POT WASH
|
|
Violation:
AN ACCUMULATION OF CONDENSATION WAS NOTED ON THE BULKHEAD OVER THE FINAL RINSE SINK. THE WATER TEMPERATURE IN THIS SINK WAS 180 °F.
|
|
Recommendation:
Lower the final sanitizing sink water temperature to 170 °F and observe the effect on the exhaust hood and surrounding deckhead. If condensation continues to occur the ventilation system should be repaired or improved to eliminate the problem.
|
|
|
Item No.:
3
|
|
Site:
Other-POTABLE WATER SYSTEM
|
|
Violation:
THE CLHORINE ANALYZER/RECORDER FOR THE LOWER LOOP OF THE POTABLE WATER DISTRIBUTION SYSTEM DISPLAYED A FREE CHLORINE RESIDUAL OF 3.67 PPM, WHILE THE MANUAL TEST RESULT WAS 4.0 PPM.
|
|
Recommendation:
The ship must have a chlorine or bromine analyzer-recorder, which must be installed at a distant point in the potable water distribution system where a significant water flow exists. The free halogen residual measured by the analyzer must compare within 0.2 ppm of the actual halogen level.
|
|
|
Item No.:
1
|
|
Site:
Other-POTABLE WATER SYSTEM
|
|
Violation:
THE CURRENT BUNKERING SYSTEM FOR CHLORINE INJECTION IS NOT FUNCTIONING PROPERLY. UNTIL THE ANALYZER/RECORDER CAN BE MOVED CLOSER TO THE INJECTION POINT TO PROVIDE A REAL-TIME TEST OF THE CHLORINE LEVEL, THE PUMP THAT IS DIRECTING CHLORINE INJECTION BASED ON READINGS FROM THE ANALYZER SHOULD BE OPERATED MANUALLY AND THE CHLORINE INJECTION SETTINGS SHOULD BE BASED ON MANUAL TESTS ONLY. WHEN TESTED MANUALLY, THE ACTUAL FREE CHLORINE LEVEL IN THE BUNKER LINE DURING ACTIVE BUNKERING WAS GREATER THAN 2.0 PPM, WHILE THE WATER FROM THE SMALL LINE FEEDING THE ANALYZER HAD A FREE CHLORINE RESIDUAL OF ONLY 1.1 PPM.
|
|
Recommendation:
Please refer to the recommendation listed under Item 30.
|
|