Cruise Ship: Seven Seas Navigator Cruise Line: Regent Seven Seas Inspection Date: 06/03/2000 Inspection Score: 98
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 11
Site: Other-MAIN GALLEY / VEG PREP AREA
Violation: THERE WAS A SMALL BAIN MARIE PAN OF COOKED PASTA SETTING ON ICE WITH A PRODUCT TEMPERATURE OF 60oF.
Recommendation: To prevent the rapid growth of microorganisms, potentially hazardous foods must be rapidly heated or cooled to the required temperature. To better maintain a temperature of 45oF or below use crushed ice and ensure the pan is set down in the ice not only setting on top of the ice.
Item No.: 11
Site: Other-MAIN GALLEY / HOT GALLEY
Violation: THERE WAS A BAIN MARIE PAN OF SLICED HAM ON THE HOT SERVICE LINE SETTING ON TOP OF ICE WITH A PRODUCT TEMPERTURE OF 60oF.
Recommendation: To prevent the rapid growth of microorganisms, potentially hazardous foods must be rapidly heated or cooled to the required temperature. To better maintain a temperature of 45oF or below use crushed ice and ensure the pan is set down in the ice not only setting on top of the ice.
Item No.: 17
Site: Other-POOL BAR
Violation: AN ICE SCOOP WAS FOUND WITH IT'S HANDLE IN DIRECT CONTACT WITH THE ICE.
Recommendation: Ice dispensing utensils shall be stored on a clean surface, on hooks fastened to the interior or exterior of the ice machine, on retractable devices attached to the bulkhead or deckhead, or in the ice with the handle extended out of the ice.
Item No.: 30
Site: Other-MAIN GALLEY / VEG PREP AREA
Violation: ONE OF THE SHELF SUPPORTS FOR THE COMBI-OVEN WAS SITTING DIRECTLY ON THE DECK BETWEEN THE OVENS.
Recommendation: After sanitizing, all equipment and utensils shall be air dried. Cleaned and sanitized equipment and utensils shall be handled and stored in a way that protects them from contamination.
Item No.: 11
Site: Other-MAIN GALLEY / HOT GALLEY
Violation: THERE WAS A SMALL BAIN MARIE PAN OF VEAL STEAKS SETTING ON TOP OF ICE NEXT TO THE GRILL. THE VEAL HAD A PRODUCT TEMPERATURE OF 58oF.
Recommendation: To prevent the rapid growth of microorganisms, potentially hazardous foods must be rapidly heated or cooled to the required temperature. To better maintain a temperature of 45oF or below use crushed ice and ensure the pan is set down in the ice not only setting on top of the ice.
Item No.: 40
Site: Other-MAIN GALLEY / POT WASH
Violation: THIS AREA WAS VERY HOT AND HUMID AND WATER WAS CONDENSING ON THE BULKHEADS AND DECKHEAD. THE TEMPERATURES OF THE WATER IN THE SANITIZE SINK WAS MEASURED AT 218oF AND THE MAXIMUM TEMPERATURE AT THE UTENSIL SURFACE OF THE POT WASHING MACHINE WAS MEASURED AT 180oF. THE SINK TEMPERATURE NEEDS TO BE A MINIMUM OF 170oF AND THE FINAL RINSE OF THE POT WASHING MACHINE ONLY NEEDES TO BE 165oF.
Recommendation: Reduce the final rinse temperatures to closer to the minimum required temperatures and this should reduce the amount of condensation forming on the bulkheads and deckhead. It will also make it more comfortable for the pot washers.