Item No.:
11
|
|
Site:
Other-WINDJAMMER BUFFET
|
|
Violation:
FISH WAS TESTED AT 129 DEGREES F. THE BACK-UP FISH WAS ALSO TESTED AND HAD A TEMPERATURE OF 118 DEGREES F. THE WARMING CABINET ALSO REGISTERED 110 DEGREES F.
|
|
Recommendation:
Sufficient baine-maries and other heat retention equipment for storing and transporting potentially hazardous food must be provided and maintained to assure that all foods are held at or above 140oF (60oC). This equipment shall not be used to heat food.
|
|
|
Item No.:
38
|
|
Site:
Other-WINDJAMMER BUFFET AND BEVERAGE STATION
|
|
Violation:
THE DECK BUFFET JUNCTURES WERE NOT ADEQUATELY COVED. THE DECK WAS ALSO SOILED IN THIS AREA.
|
|
Recommendation:
It is required that decks be maintained so as to be durable and easily cleanable.
|
|
|
Item No.:
21
|
|
Site:
Other-WINDJAMMER BEVERAGE STATIONS
|
|
Violation:
THE BACK WALL OF THE BEVERAGE STATIONS' TECHNICAL SPACES WERE CONSTRUCTED OF ABSORBENT MATERIAL.
|
|
Recommendation:
Nonfood preparation equipment must be easily cleanable, in good repair, and corrosion-resistant.
|
|
|
Item No.:
29
|
|
Site:
Other-WINDJAMMER BEVERAGE STATION
|
|
Violation:
THE BACK WALL OF THE BEVERAGE STATIONS' TECHNICAL COMPARTMENTS HAD LIQUID SPLASH THAT DRAINED ON TO THE DECK.
|
|
Recommendation:
Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
|
|
|
Item No.:
38
|
|
Site:
Other-POOL BAR
|
|
Violation:
THE GROUT WAS RECESSED BEHIND THE SERVICE BAR.
|
|
Recommendation:
It is required that decks be maintained so as to be durable and easily cleanable.
|
|
|
Item No.:
21
|
|
Site:
Other-POOL BAR
|
|
Violation:
THE DISPENSING HOSES WERE DRAPED ON THE COUNTER.
|
|
Recommendation:
Surfaces of equipment not intended for contact with food, but which are exposed to splash or food debris or which otherwise require frequent cleaning, shall be designed and fabricated to be smooth, washable, free of unnecessary ledges, projections, or crevices, and readily accessible for cleaning, and shall be of such material and in such repair as to be easily maintained in a clean and sanitary condition.
|
|
|
Item No.:
28
|
|
Site:
Other-GALLEY DECK 4
|
|
Violation:
SEVERAL PREVIOUSLY CLEANED CUTTING BOARDS WERE FOUND SOILED WITH FOOD RESIDUE.
|
|
Recommendation:
To prevent cross-contamination, pots, pans, utensils and other food contact surfaces of equipment shall be thoroughly washed, rinsed and sanitized after each use and prior to storage. Any items which are found to be soiled after being washed, must be returned to the warewashing area for immediate re-washing.
|
|
|
Item No.:
21
|
|
Site:
Other-GALLEY DECK 4
|
|
Violation:
SEVERAL UTENSILS WERE EITHER BROKEN OR MELTED MAKING THEM DIFFICULT TO CLEAN.
|
|
Recommendation:
Replace damaged utensils.
|
|
|
Item No.:
38
|
|
Site:
Other-GALLEY DECK 4
|
|
Violation:
THE BULKHEAD ADJACENT TO THE ELEVATOR WAS SOILED. THERE WERE ALSO SOME LOOSE SEAMS IN THIS AREA.
|
|
Recommendation:
It is required that decks be maintained so as to be durable and easily cleanable. Decks and bulkheads shall also be routinely cleaned.
|
|
|
Item No.:
21
|
|
Site:
Other-GALLEY DECK4
|
|
Violation:
THE COLD PREP REFRIGERATOR GASKETS HAD OPEN CHANNELS AT THE BASE OF THE UNIT.
|
|
Recommendation:
Refrigerator gaskets shall be easily cleanable without breaks in the material. The corners shall be closed and sealed and hollow sections shall be sealed.
|
|
|
Item No.:
34
|
|
Site:
Other-GALLEY DECK 4
|
|
Violation:
IN FOUR LOCATIONS HAND WASHING SINKS WERE PARTIALLY BLOCKED. HOWEVER, FOOD PREP WAS NOT ACTIVE AT THIS TIME. THIS SHOULD NOT BE HAPPENING REGARDLESS OF THE LEVEL OF FOOD SERVICE IN PROGRESS.
|
|
Recommendation:
Handwashing sinks must be accessible to employees at all times.
|
|
|
Item No.:
28
|
|
Site:
Other-GALLEY DECK 4
|
|
Violation:
A CAN OPENER WAS FOUND SOILED IN THE MAIN GALLEY.
|
|
Recommendation:
To prevent cross-contamination, pots, pans, utensils and other food contact surfaces of equipment shall be thoroughly washed, rinsed and sanitized after each use and prior to storage. Any items which are found to be soiled after being washed, must be returned to the warewashing area for immediate re-washing.
|
|
|
Item No.:
21
|
|
Site:
Other-GALLEY DECK 4
|
|
Violation:
NUMEROUS WAITER TRAYS WERE FOUND CRACKED AND CHIPPED.
|
|
Recommendation:
Nonfood preparation equipment must be easily cleanable, in good repair, and corrosion-resistant.
|
|
|
Item No.:
7
|
|
Site:
Other-GALLEY DECK 4
|
|
Violation:
ONE BACKFLOW PREVENTION DEVICE BENEATH THE HAND WASHING SINK WAS LEAKING.
|
|
Recommendation:
Water supply lines and fixtures must be free from leaks and properly installed. Wastewater from equipment and sinks must be properly drained to prevent pooling or leaking of water on the deck.
|
|
|
Item No.:
38
|
|
Site:
Other-MAIN DINING ROOM
|
|
Violation:
THE CARPETING AROUND THE WAITER STATIONS WAS SEPARATING FROM THE TILED PORTION OF THE DECK.
|
|
Recommendation:
It is required that decks be maintained so as to be durable and easily cleanable.
|
|
|
Item No.:
38
|
|
Site:
Other-MAIN DINING ROOM BREAKFAST STATION
|
|
Violation:
THE SEALANT ON THE BULKHEAD WAS PEELING.
|
|
Recommendation:
Decks, bulkheads, and deckheads in food preparation, warewashing, and storage areas, including pantries, shall be designed and constructed for easy cleanability, shall be corrosion-resistant, maintained in good repair, and kept clean.
|
|
|
Item No.:
38
|
|
Site:
Other-PROVISIONS DRY STORES
|
|
Violation:
THE DECK WAS SOILED WITH DIRT AND FOOD SPILLAGE.
|
|
Recommendation:
It is required that decks be maintained so as to be durable and easily cleanable.
|
|
|
Item No.:
14
|
|
Site:
Other-WINDJAMMER BUFFET
|
|
Violation:
THE BREAD, ROLLS, AND SALAD DRESSING WERE PLACED FORWARD OF THE PORTABLE SNEEZE GUARDS.
|
|
Recommendation:
Display tables or buffet lines for service of unpackaged foods must be effectively shielded so as to intercept any source of contamination from the consumer. Appropriate food shielding (sneeze guards) should be provided.
|
|
|
Item No.:
4
|
|
Site:
Other-POTABLE WATER GARBAGE ROOM
|
|
Violation:
THE VENT HOLE ON THE BACKFLOW PREVENTION DEVICE CONNECTED TO THE EXTRACTOR POTABLE WATER LINE WAS PLUGGED.
|
|
Recommendation:
Vacuum breakers and backflow preventers must be properly installed and maintained in good repair at all times to assure reliable operation.
|
|
|
Item No.:
4
|
|
Site:
Other-POTABLE WATER PHOTO LAB
|
|
Violation:
A HOSE WAS CONNECTED TO THE POTABLE WATER LINE AT THE SINK WITHOUT A BACKFLOW PREVENTION DEVICE.
|
|
Recommendation:
Vacuum breakers and backflow preventers must be properly installed and maintained in good repair at all times to assure reliable operation.
|
|