Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Vision of the Seas Cruise Line: Royal Caribbean International Inspection Date: 01/20/2002 Inspection Score: 93
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: *
Site: Other-CAS
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
Recommendation:
Item No.: 16
Site: Other-WINDJAMMER GALLEY
Violation: THE WALK-IN REFRIGERATOR HAD CUT HONEYDEW AND CANTELOUPE MELONS PREPARED ON 01/18/2002 WITH TEMPERATURE READINGS OF 48°F AND 49°F RESPECTIVELY. THE AMBIENT AIR THERMOMETER INSIDE THE UNIT HAD A TEMPERATURE READING OF 40°F. ALL OTHER FOODS WERE BELOW 41° F.
Recommendation: 7.3.5.3.1.1 Potentially hazardous food shall be maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above,; or (2) At 5°C (41°F) or less.
Item No.: 21
Site: Other-MAIN GALLEY
Violation: THE INTERIOR SPACE OF THE VITALITY JUICE MACHINE WAS NOT EASILY CLEANABLE.
Recommendation: 7.4.2.2.6 Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Other-MAIN GALLEY - BAKERY
Violation: ONE OF THE OVEN LIGHTS WAS NOT WORKING.
Recommendation: 7.4.5.1.2 Nonfood-contact equipment shall be maintained in good repair and proper adjustment including: (1) Equipment shall be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines.
Item No.: 21
Site: Other-MAIN GALLEY - SOUP KETTLE
Violation: LOOSE SEALANT WAS NOTED ON THE OUTER RIM OF THE SOUP KETTLES.
Recommendation: The loose sealant should be made to fit firmly around the outer rim of the kettle.
Item No.: 24
Site: Other-MAIN GALLEY - POTWASH
Violation: IT WAS OBSERVED THAT THE POT WASHING STAFF WAS NOT IMMERSING CLEANED ITEMS IN THE FINAL SANITIZING RINSE WATER FOR AT LEAST 30 SECONDS.
Recommendation: 7.5.6.1.1 In a manual operation, if immersion in hot water is used for sanitizing: (1) The temperature of the water shall be maintained at 77°C, (171°F) or above; and (2) The food-contact surface shall be immersed for at least 30 seconds.
Item No.: 26
Site: Other-MAIN GALLEY-DISHWASH
Violation: SEVERAL PREVIOUSLY CLEANED PLATES WERE SOILED WITH A FOOD RESIDUE.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 27
Site: Other-MAIN GALLEY
Violation: THE INTERIOR SPACE OF THE VITALITY WAS SOILED WITH A JUICE RESIDUE.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Other-PROVISION - VEGETABLE BOX
Violation: THERE WAS A LOOSE PROFILE STRIP LOCATED IN THE CORNER OF THE COOLER.
Recommendation: The profile strip should be re-attached in the corner of the cooler.
Item No.: 33
Site: Other-PROVISIONS
Violation: SOME OF THE PLASTIC STOPPERS WERE MISSING FROM THE DOOR FRAME. AN INVERTED NIPPLE WAS ALSO NEEDED FOR THE DOOR FRAME.
Recommendation: The plastic stoppers should be replaced around the door frame and inverted nipples should be provided for the door locking mechanism.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program