Cruise Ship: Wind Surf Cruise Line: Windstar Cruises Inspection Date: 03/03/2002 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 08
Site: Other-GARBAGE ROOM
Violation: THERE WAS A HOSE BIB TYPE BACKFLOW PREVENTION DEVICE INSTALLED ON THE HOSE USED TO WASH DOWN THE AREA AND THERE WAS A SPRAY NOZZLE ATTACHED TO THE END OF THE HOSE.
Recommendation: Install a continuous pressure type backflow preventer on the soppy line to the hose.
Item No.: 36
Site: Other-PROVISIONS / FISH FREEZER
Violation: THE LIGHT LEVEL IN THE WALK-IN WAS LESS THAN 110 LUX. LIGHTING LEVEL CORRECTED DURING INSPECTION.
Recommendation: 7.7.5.1.2 The light intensity shall be at least 110 Lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning.
Item No.: 19
Site: Other-BEVERAGE STORAGE AREA
Violation: BOXES OF LIQUOR WERE FOUND SETTING ON THE DECK.
Recommendation: Ensure that all boxes are stored off of the decks.
Item No.: 16
Site: Other-CREW MESS
Violation: SEVERAL BOXES OF SKIM MILK WHERE FOUND IN THE UNDERCOUNTER REFRIGERATOR WITH PRODUCT TEMPERATURES OF 44°F. THE REFRIGERATOR WAS NOT LABELED AS DAY SERVICE. THE REFRIGERATORS WERE LABELED DURING THE INSPECTION.
Recommendation: 7.3.5.3.7 Refrigerated, ready-to-eat, potentially hazardous food may be held at 7°C (45°F) up to 24 hours in existing short term holding refrigeration equipment provided: (1) The equipment is designated by a permanent label affixed to it indicating the maximum allowable product temperature is 7°C (45°F) and the maximum allowable storage time is 24 hours; (2) All containers of potentially hazardous foods placed in the unit must be labeled with a date and time by which food shall be used or discarded; (3) Potentially hazardous foods when placed in the equipment shall be at 5°C (41°F) or less; and (4) When the equipment is upgraded or replaced, it shall be with equipment that can maintain the potentially hazardous food at 5°C (41°F) or less.
Item No.: 08
Site: Other-POTABLE WATER / BACKFLOW PROTECTION
Violation: PRESSURE DIFFERENCES WERE NOT RECORDED FOR THE TESTING OF THE REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTERS.
Recommendation: 5.7.2.2.2 Backflow prevention devices requiring testing, for example reduced pressure backflow preventer and double check valves with test cocks, shall be inspected and tested with a test kit at least annually. Test results showing the pressure differences on both sides of the valves shall be maintained for each device.
Item No.: 07
Site: Other-POTABLE WATER / BACKFLOW PROTECTION
Violation: REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTERS WERE NOT INSTALLED ON THE INTERNATIONAL FIRE CONNECTIONS.
Recommendation: Install reduced pressure principle backflow preventers on the international fire connections.
Item No.: 33
Site: Other-MAIN DINING ROOM
Violation: THE CARPETING IN FRONT OF THE WAITER STATIONS WERE SOILED WITH FOOD RESIDUE. THE DECKS IN FRONT OF THE WAITER STATIONS WERE NOT EASY TO CLEAN.
Recommendation: Replace the carpet in front of the waiter stations.
Item No.: *
Site: Other-GENERAL COMMENT
Violation: THE OVERALL KNOWLEDGE OF THE CREW WAS OUTSTANDING. THIS VESSEL HAD NEVER BEEN INSPECTED UNDER THE HOLLAND AMERICA MANAGEMENT. ALL PERSONNEL INVOLVED IN PREPARING THE VESSEL ARE COMMENDED.
Recommendation:
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
Recommendation:
*Inspections scores of 85 or lower are NOT satisfactory