Cruise Ship: Seadream II Cruise Line: Sea Dream Yacht Club Inspection Date: 02/23/2002 Inspection Score: 81
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 05
Site: Other-POTABLE WATER
Violation: THE FREE HALOGEN RESIDUAL MEASURED BY THE HALOGEN ANALYZER HAD A DIFFERENCE OF MORE THAN 0.2 PPM FROM THE MANUAL TEST. THE ANALYZER NOTED 1.96 PPM WHILE THE MANUAL TEST NOTED 0.88 PPM.
Recommendation: 5.5.1.2.3 The free residual halogen measured by the halogen analyzer shall be ±0.2 mg/L (ppm) of the free residual halogen measured by the manual test.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE CLEANING AND DISINFECTION OF THE POTABLE WATER TANKS DURING DRY DOCKS AND AFTER MAINTENANCE WAS NOT RECORDED.
Recommendation: 5.3.4.1.2 Potable water tanks shall be inspected, cleaned, and disinfected during dry docks and wet docks, or every 2 years, whichever is less. 5.3.4.1.3 Documentation of the cleaning shall be maintained for 12 months and shall be available to the VSP for review during inspections.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE CROSS-CONNECTION CONTROL PROGRAM FOR THE VESSEL HAS NOT BEEN COMPLETED.
Recommendation: Complete the cross-connection control program for the vessel.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE REDUCED PRESSURE ZONE BACKFLOW PREVENTION DEVICES HAVE NOT BEEN INSTALLED ON THE INTERNATIONAL SHORE CONNECTIONS THAT SERVE THE FIRE SUPPRESSION SYSTEM OF THE VESSEL.
Recommendation: Install reduced pressure principle backflow prevention devices on the international shore connections that serve the fire suppression system of the vessel.
Item No.: 08
Site: Other-POTABLE WATER
Violation: A SMALL LAUNDRY MACHINE ACROSS FROM THE SPA FILTER ROOM WAS NOT EQUIPED WITH THE PROPER BACKFLOW PREVENTION DEVICES.
Recommendation: 5.7.1.2.5 A continuous pressure-type backflow preventer shall be installed when a valve is located downstream from the backflow preventer.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE SIGN AT THE POTABLE WATER FILLING LINE IN THE STARBOARD BUNKER STATION WAS NOT CLEAR.
Recommendation: 5.3.2.1.5 Each potable water filling line shall be painted light blue and clearly marked "POTABLE WATER FILLING" in letters at least 13 mm (0.5 inch) high, stamped on a non-corrosive label plate or the equivalent and located at or near the point of hose connection.
Item No.: 06
Site: Other-POTABLE WATER
Violation: DURING THE INSPECTION THE HALOGEN RESIDUAL WAS OVER 5.0 PPM FOR APPROXIMATELY 15 MINUTES. THE ONLY ALARM ON THIS SYSTEM IS A SMALL RED LIGHT AT THE ANALYZER NEAR THE BRIDGE. THE LOCATION OF THIS ALARM WAS NOT SUITABLE.
Recommendation: Relocate this alarm to an area that is manned 24 hours. It would be advisable to include an audible alarm as well in a manned location. In addition, a low level alarm should be installed.
Item No.: 04
Site: Other-POTABLE WATER
Violation: DURING THE INSPECTION THE FREE CHLORINE IN THE DISTRIBUTION SYSTEM WAS OVER 5.0 PPM FOR APPROXIMATELY 15 MINUTES. THE LEVEL OF CHLORINE WENT FROM 1.96 PPM TO 5.9 PPM, AS NOTED ON THE ANALYZER RECORDER. THE LEVEL WENT DOWN AND STABILIZED AFTER APPROXIMATELY 15 MINUTES. THE HIGH LEVEL ALARM ON THIS SYSTEM WAS INADEQUATE.
Recommendation: 5.4.1.2.1 The halogenation device shall provide continuous halogenation of the potable water distribution system and shall maintain a free residual halogen of 0.2 mg/L (ppm) and 5.0 mg/L (ppm) throughout the distribution system.
Item No.: 07
Site: Other-POTABLE WATER
Violation: THIS VESSEL HAS 6 POTABLE WATER TANKS. ALL OF THE TANKS SHARE A COMMON WALL WITH THE HULL OF THE VESSEL. THE VESSEL IS IN THE PROCESS OF INSTALLING SALINITY METERS AND ALARMS FOR THE TANKS BUT HAS NOT COMPLETED THE WORK AND HAS NOT APPLIED FOR A VARIANCE.
Recommendation: This vessel must immediately for a variance. The variance application must include certain elements that address protecting the potable water supply from salt water intrusion. These elements include but are not limited to salinity meters and alarms.
Item No.: 10
Site: Other-POOL AND SPA
Violation: VERIFY THAT THE POOL DRAIN COVER IS ANTI-VORTEX IN DESIGN FOR THE FLOW RATE OF THE POOL. VERIFY THAT THE SPA DRAIN COVER IS ANTI-VORTEX. TWO FASTENERS WERE MSSING ON THE SPA DRAIN COVER. THE DRAIN COVER WAS VERY LOOSE.
Recommendation: 6.4.1.2.2 Anti-vortex drain covers shall be provided on swimming pools and whirlpool spas. Drain covers must be properly attached.
Item No.: *
Site: Other-POOL AND SPA
Violation: PLACE A LABEL OVER THE POOL AND SPA SIGN TO MAKE IT CLEAR THAT THE SIGN IS FOR THE POOL AND SPA RULES. THE LARGE "THE POOL BAR" SIGN OVER THE POOL AND SPA RULES SIGN CAN CAUSE INDIVIDUALS TO DISREGARD THIS SIGN.
Recommendation:
Item No.: *
Site: Other-POOL AND SPA
Violation: ACCORDING TO THE SHIP'S STAFF THE POOL AND SPA HAVE NOT BEEN USED SINCE THE LAST DRY DOCK WHICH ENDED AROUND 01/15/02. THERE WERE NO POOL/SPA HALOGENATION RECORDS COVERING THE PERIOD FROM THE DRY DOCK TO THE INSPECTION.
Recommendation:
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT INSTRUCTIONS
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SEA DREAM II - CAS - [02/23/2002] .
Recommendation:
Item No.: 33
Site: Other-DINING ROOM
Violation: COVING WAS NOT PROVIDED AT THE THE WAIT STATIONS ALONG COUNTER-DECK JUNCTURES.
Recommendation: Provide coving at the counter-deck juncture at the wait stations.
Item No.: 21
Site: Other-DINING ROOM
Violation: THE INTERIORS OF THE WAIT STATIONS WERE OF WOODEN CONSTRUCTION AND NOT EASY TO CLEAN.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 21
Site: Other-MAIN GALLEY
Violation: REFRIGERATOR G-18 HAD A LARGE GAP BETWEEN THE BULKHEAD AND THE UNIT BESIDE THE SOUP STATION THAT MUST BE CLOSED TO ALLOW FOR EASY CLEANING.
Recommendation: Provide a profile strip to close this gap.
Item No.: 16
Site: Other-MAIN GALLEY - GARDE MANGER
Violation: REFRIGERATOR G-12 WAS NOT WORKING PROPERLY AND SEVERAL CONTAINERS OF PREPARED SALAD DRESSINGS, CREAM CHEESE, SOFT CHEESES, AND OTHER POTENTIALLY HAZARDOUS FOODS THAT HAD BEEN STORED OVER NIGHT WERE AT 58°F.
Recommendation: 7.3.5.3.1.1 Potentially hazardous food shall be maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above,; or (2) At 5°C (41°F) or less.
Item No.: 26
Site: Other-MAIN GALLEY - GARDE MANGER
Violation: THE MEAT SLICER HAD FOOD RESIDUE LEFT ON ITS SURFACES AFTER THE CLEANING PROCESS.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 26
Site: Other-MAIN GALLEY - GARDE MANGER
Violation: NUMEROUS LEXAN CONTAINERS THAT HAD BEEN CLEANED AND STORED ON SHELVES IN THE GARDE MANGER HAD FOOD RESIDUE AND GREASE ON THEIR SURFACES.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 18
Site: Other-MAIN GALLEY - HOT GALLEY
Violation: RAW BACON WAS STORED ABOVE SLICED "READY TO EAT" CANANDIAN BACON IN THE REACH-IN REFRIGERATOR BESIDE THE HOT SERVICE LINE.
Recommendation: 7.3.3.2.1.1 Food shall be protected from cross-contamination by: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food including other raw animal food such as fish for sushi or molluscan shellfish, or other raw ready-to-eat food such as vegetables, and cooked ready-to-eat food; so products do not physically touch, and so as to prevent dripping of one product into another.
Item No.: 21
Site: Other-MAIN GALLEY - HOT GALLEY
Violation: CHIPPING PAINT WAS NOTED ON THE CONDENSER UNIT IN THE WALK-IN REFRIGERATOR.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 21
Site: Other-MAIN GALLEY - GENERAL
Violation: NON-FOOD CONTACT SURFACES OF EQUIPMENT THROUGHOUT THE GALLEY, SUCH AS GRILLS, FRYERS, TILTING PANS, AND OTHER ITEMS HAD OPEN SEAMS, HOLES, AND OTHER DIFFICULT TO CLEAN FEATURES.
Recommendation: 7.4.2.2.6 Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 26
Site: Other-MAIN GALLEY - GENERAL
Violation: FOOD CONTACT SURFACES OF EQUIPMENT AND UTENSILS SUCH AS; POTS AND PANS IN THE POT WASH AREA; KNIVES AND UTENSILS IN THE HOT GALLEY PREPARATION AREA; AND PLASTIC FOOD CONTAINERS IN VARIOUS LOCATIONS, THAT HAD BEEN CLEANED HAD FOOD RESIDUE ON THEIR SURFACES.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 22
Site: Other-DISHWASHING - GENERAL
Violation: THE MAIN GALLEY DISHWASHER RINSE TANK THERMOMETER WAS INACURRATE. THREE DISHWASHERS WERE INOPERATIONAL AT THE TIME OF THE INSPECTION, INCLUDING THE MAIN DISHWASHER FOR THE TOPSIDE RESTAURANT.
Recommendation: 7.5.2.1.1 Water temperature measuring devices: (1) That are scaled in Celsius or dually scaled in Celsius and Fahrenheit shall be designed to be accurate to ±1.5°C in the intended range of use. (2) That are scaled only in Fahrenheit shall designed to be accurate to ±3°F in the intended range of use. 7.5.4.1.1 Warewashing equipment shall be maintained in good repair and proper adjustment including: (1) Warewashing equipment shall be maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines. (2) Water pressure, and water temperature measuring devices shall be maintained in good repair and be accurate within the intended range of use.
Item No.: 18
Site: Other-PROVISIONS
Violation: RAW AND COOKED PRODUCTS WERE STORED IN CLOSE CONTACT ON THE SAME SHELVES IN THE FISH FREEZER AND MEAT FREEZER. RAW LOBSTER WAS STORED ON TOP OF A BOX OF CAVIAR.
Recommendation: 7.3.3.2.1.1 Food shall be protected from cross-contamination by: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food including other raw animal food such as fish for sushi or molluscan shellfish, or other raw ready-to-eat food such as vegetables, and cooked ready-to-eat food; so products do not physically touch, and so as to prevent dripping of one product into another.
Item No.: 33
Site: Other-PROVISIONS
Violation: DECK-BULKHEAD JUNCTURES IN THE COLD ROOMS WERE NOT PROVIDED WITH COVING.
Recommendation: 7.7.4.1.3 Bulkhead and deck junctures shall be coved.
Item No.: 21
Site: Other-MAIN GALLEY BAKERY
Violation: THE ICE CREAM STATION WAS NOT EASY TO CLEAN DUE TO GAPS, AND A LARGE PIANO HINGE LOCATED ON THE COVER.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material. 7.4.2.2.6 Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Other-TOPSIDER RESTAURANT
Violation: THE COUNTER BELOW THE COMBI-OVEN AND THE BASE OF THE PLATE DISPENSER UNIT HAD NOT BEEN CLEANED ADEQUATELY.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 36
Site: Other-PANTRY 3
Violation: LIGHTING LEVELS WERE INADEQUATE AROUND THE DISHWASHER.
Recommendation: 7.7.5.1.1 The light intensity shall be at least 220 Lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 36
Site: Other-BUTCHER SHOP
Violation: LIGHT LEVELS WERE INADEQUATE IN THE BUTCHER SHOP PREPARATION AREA.
Recommendation: 7.7.5.1.1 The light intensity shall be at least 220 Lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 20
Site: Other-FOOD SERVICE GENERAL
Violation: FOOD CONTACT SURFACES OF OLDER EQUIPMENT SUCH AS THE INTERIOR OF REFRIGERATORS HAD OPEN SEAMS, GAPS, HOLES, SLOTTED SCREWS AND OTHER NON-EASILY CLEANABLE FEATURES.
Recommendation: 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 33
Site: Other-FOOD SERVICE GENERAL
Violation: DECKS, BULKHEADS, AND DECKHEADS HAD OPEN SEAMS, EXPOSED FASTENERS, CRACKED TILES, EXPOSED PIPES AND WIRING, AND OTHER NON-EASILY CLEANABLE FEATURES.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning. 7.7.4.1.7 Exposed utility service lines and pipes, including lines for fire detection and protection systems, shall be installed so they do not obstruct or prevent cleaning.
Item No.: 20
Site: Other-FOOD SERVICE GENERAL
Violation: THE ICE DEFLECTORS WERE NOT REMOVABLE IN THE ICE MACHINES THROUGHOUT THE SHIP.
Recommendation: 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 40
Site: Other-INTEGRATED PEST MANAGEMENT
Violation: A LIST OF THE PESTICIDES USED AND THEIR EFFECTIVENESS WAS NOT DEVELOPED. THE VESSEL HAS YET TO BEGIN CONDUCTING MONITORING INSPECTIONS.
Recommendation: 8.1.2.1.1 The Integrated Pest Management Plan shall include a record of pesticides used and their effectiveness. 8.2.1.1.3 Incoming shipments of food and supplies shall be routinely inspected for evidence of insects, rodents, and other pests. 8.2.1.1.4 The vessel's food areas shall be inspected under the Integrated Pest Management Plan at a frequency that can quickly detect the evidence of pests or the creation of harborage conditions.
*Inspections scores of 85 or lower are NOT satisfactory