Item No.:
12
|
|
Site:
Other-MAIN GALLEY - HOT GALLEY
|
|
Violation:
A HALF-FULL 1.5 LITER BOTTLE OF MINERAL WATER WAS LEFT AT A PORTHOLE WINDOW NEAR THE SOUP STATION. IT WAS REPORTEDLY LEFT BY A CHEF WHO WAS DRINKING FROM IT. THERE WAS NO INSTALLED DRINKING FOUNTAIN IN THIS GALLEY OR IN THE DEAUVILLE FINISHING GALLEY.
|
|
Recommendation:
7.2.4.1.1
An employee shall eat, drink, or use any form of tobacco only in designated areas where the contamination of exposed food; clean equipment, utensils, and linens; unwrapped single-service and single-use articles; or other items needing protection can not result.
|
|
|
Item No.:
26
|
|
Site:
Other-MAIN GALLEY - POT WASH
|
|
Violation:
PREVIOUSLY CLEANED WHISKS, BINS, BAIN PANS, AND A CUTTING BOARD WERE FOUND SOILED WITH FOOD RESIDUE ON THE CLEAN POT STORAGE RACKS.
|
|
Recommendation:
7.3.3.4.1
Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
|
|
|
Item No.:
28
|
|
Site:
Other-MAIN GALLEY - POT WASH
|
|
Violation:
SEVERAL SOILED CROISSANT BAKING SHEETS WERE STACKED ON THE DECK AT THE 3 COMPARTMENT SINK.
|
|
Recommendation:
Never store food equipment, pans, or utensils on the deck.
|
|
|
Item No.:
26
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
A SOILED KNIFE WAS FOUND STORED IN THE KNIFE LOCKER.
|
|
Recommendation:
7.3.3.4.1
Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
|
|
|
Item No.:
33
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
A FEW CRACKED OR BROKEN DECK TILE WERE NOTED IN FRONT AND BEHIND THE HEAVY COOKING EQUIPMENT AT THE HOT GALLEY.
|
|
Recommendation:
7.7.4.1.1
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
|
|
|
Item No.:
26
|
|
Site:
Other-MAIN GALLEY - DISHWASH
|
|
Violation:
SEVERAL PREVIOUSLY CLEANED UTENSILS WERE FOUND ON THE CLEAN STORAGE RACK SOILED WITH FOOD DEBRIS.
|
|
Recommendation:
7.3.3.4.1
Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
|
|
|
Item No.:
17
|
|
Site:
Other-FOODSERVICE GENERAL
|
|
Violation:
THE SHIP SERVES VARIOUS NON-TUNA SPECIES OF FISH IN UNDERCOOKED OR RAW FORM, SUCH AS SUSHI, CEVICHE, AND CARPACCIO, BUT THERE IS NO RECORD DOCUMENTING THAT EITHER THE SHIP OR THE FISH SUPPLIER FROZE THESE FISH TO A SAFE TEMPERATURE AND TIME TO KILL PARASITES.
|
|
Recommendation:
7.3.4.2.2
If raw, raw-marinated, partially cooked, or marinated-partially cooked fish are served in ready-to-eat form:
(1) The person in charge shall record the freezing temperature and time to which the fish are subjected and shall retain the records on the vessel for 90 calendar days beyond the time of service or sale of the fish; or (2) If the fish are frozen by a supplier, a written agreement or statement from the supplier stipulating that the fish supplied are frozen to a safe temperature and a time.
|
|
|
Item No.:
*
|
|
Site:
Other-COMMENT
|
|
Violation:
HOT AND COLD TEMPERATURES OF VARIOUS POTENTIALLY HAZARDOUS FOODS WERE EXCELLENT IN THE GALLEYS AND GRAND BLEU BUFFET.
|
|
Recommendation:
|
|
|
Item No.:
*
|
|
Site:
Other-COMMENT
|
|
Violation:
IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY.
PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV
USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
|
|
Recommendation:
|
|
|
Item No.:
08
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
THE INTERNATIONAL SHORE CONNECTIONS WERE NOT PROTECTED BY REDUCED PRESSURE PRINCIPAL BACKFLOW (RPZ) PREVENTION DEVICES.
|
|
Recommendation:
5.7.1.1.3
The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present:
(1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
|
|
|
Item No.:
08
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
THE REDUCED PRESSURE PRINCIPAL BACKFLOW PREVENTERS WERE NOT BEING TESTED.
|
|
Recommendation:
5.7.2.2.2
Backflow prevention devices requiring testing, for example reduced pressure backflow preventer and double check valves with test cocks, shall be inspected and tested with a test kit at least annually. Test results showing the pressure differences on both sides of the valves shall be maintained for each device.
5.7.2.2.3
The inspection and test results for backflow preventers shall be retained for at least 12 months and shall be available to the VSP for review during inspections.
|
|
|
Item No.:
20
|
|
Site:
Other-VENICE BAR
|
|
Violation:
THE GASKET SEPARATING THE UPPER AND LOWER BINS OF THE ICE MACHINE WAS IN POOR REPAIR.
|
|
Recommendation:
Replace the damaged gasket.
|
|
|
Item No.:
06
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
THE ANALYZER CHART RECORDER HAD A RANGE OF 0 TO 500.
|
|
Recommendation:
5.5.2.1.1
Halogen analyzer-chart recorder charts shall have a range of 0.0 to 5.0 mg/L (ppm) and have a recording period of 24 hours.
|
|