Cruise Ship: Seadream II Cruise Line: Sea Dream Yacht Club Inspection Date: 03/30/2002 Inspection Score: 94
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 21
Site: Other-TOP SIDE RESTAURANT
Violation: THERE WERE OPEN GAPS AT THE HOT SERVICE PASS-THROUGH DOUBLE DOOR LOCKING PINS.
Recommendation: Profile these gaps with inverted nipple recess pieces.
Item No.: 33
Site: Other-TOP SIDE RESTAURANT
Violation: THE JUNCTURE WHERE THE DECK JOINS THE BULKHEAD IN THE HOT AND COLD PANTRY SECTIONS WAS EITHER NOT COVED OR SMALL SECTIONS WERE COVED WTH A SOFT SEALANT. THE FRONT COUNTER AND DECK JUNCTURE WAS NOT COVED ON THE PASSENGER SIDE OF THESE SERVICE SECTIONS EITHER.
Recommendation: Provide coving to a minimum 10 mm radius in these areas. Ensure the coving is a hard, durable material, not soft sealant.
Item No.: 37
Site: Other-TOP SIDE GALLEY - HOT GALLEY
Violation: THIS AREA WAS EXCESSIVELY HOT AND HUMID. EMPLOYEES WORKING AT THE COOKING EQUIPMENT IN THE SPACE WERE PERSPIRING PROFUSELY.
Recommendation: A ventilation survey is warranted in this space. It appears that the exhaust hood fan unit was not sized correctly to match the high heat produced by the cooking equipment installed beneath.
Item No.: 15
Site: Other-GALLEY - VEGETABLE WALK-IN
Violation: 5 BOXES FILLED WITH RAW TOMATOES WERE LABELED 'USE FIRST'. THE TOP BOX WAS HALF-FULL AND ALL THE TOMATOES WERE EITHER SPLIT OPEN FROM DAMAGE OR VISIBLY SPOILED. THIS BOX WAS DISCARDED IMMEDIATELY. THE LOWER BOXES WERE FULL WITH ONLY ON OR TWO TOMATOES SEVERELY DAMAGED OR SPOILED.
Recommendation: Ensure that when stock is rotated for first use there is a thorough hand inspection where spoiled or severely damaged fruits or vegetables are removed. Always dispose of those damaged or spoiled items so there is no risk that they will be prepared or served.
Item No.: 27
Site: Other-GALLEY - BAKERY/PASTRY
Violation: THE TOP SURFACE OF THE 4 DOOR BAKING OVEN WAS HEAVILY SOILED WITH DIRT AND DUST DEBRIS.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 19
Site: Other-GALLEY - BAKERY/PASTRY
Violation: TWO SMALL PIPING BAGS FILLED WITH WITH CHOCOLATE WERE STORED DIRECTLY ON TOP OF THE 4 DOOR BAKING OVEN TO KEEP WARM. THE TOP SURFACE OF THE OVEN WAS HEAVILY SOILED WITH DIRT AND DUST DEBRIS. THE PASTRY PIPING BAGS WERE DISCARDED IMMEDIATELY.
Recommendation: Protect these items by setting them in a small container to prevent them touching the top of the oven directly.
Item No.: 26
Site: Other-GALLEY - BAKERY/PASTRY
Violation: PREVIOUSLY CLEANED BREAD BAKING PANS WERE FOUND SOILED WITH ENCRUSTED FOOD AND GREASE RESIDUE ON A CLEAN STORAGE SHELF.
Recommendation: 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized. These items can be fully scoured and cleaned routinely and re-seasoned by the staff for the baking consistency desired.
Item No.: 19
Site: Other-GALLEY - DRY STORAGE ROOM
Violation: OPENED BAGS OF VARIOUS DRY FLOURS AND POWDERED SUGAR HAD CUTS ALONG THE BAG OR WERE NOT COVERED OR SEALED TIGHTLY TO PROTECT THE PRODUCT INSIDE.
Recommendation: When opened bags of flours, sugars, and other dry goods are re-cclosed they should be sealed in a way that prevents contamination. If such bags are damaged the product must be transferred to another container which can be sealed properly.
Item No.: 21
Site: Other-FOOD SERVICE GENERAL
Violation: AN ABSORBENT GASKET WAS PRESENT ON DOOR FRAMES OF THE ICE MAKERS AND BETWEEN THE UPPER MAKER AND LOWER BIN ON ALL THE OLDER ICE MACHINES.
Recommendation: Replace the gaskets on the upper doors and along the perimeter where the maker joins the bin in all the older ice machines. Ensure the replacement gasket is non-absorbent. Soft sealant is not approved for such applications.
Item No.: 33
Site: Other-MAIN DINING ROOM
Violation: THE JUNCTURE WHERE THE DECK MEETS THE WAITER STATIONS WAS NOT COVED.
Recommendation: Cove this area with a hard, durable material to a radius of 10 mm.
Item No.: *
Site: Other-COMMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
Recommendation:
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program