Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Disney Magic Cruise Line: Disney Cruise Lines Inspection Date: 06/15/2002 Inspection Score: 99
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 20
Site: Other-CREW GALLEY
Violation: THE BLAST CHILLER CONTAINED A 3-TIER RACK INSIDE IT. IT SHOULD BE REPLACED WITH AT LEAST A 6-TIER OR LARGER RACK.
Recommendation:
Item No.: 22
Site: Other-DISHWASHING-GENERAL
Violation: DATA PLATES FOR THE DISHWASHERS STATED CONVEYOR SPEED WAS 1400 PLATES PER HOUR. GLASS WASHERS WERE 100 RACKS PER HOUR. NONE OF THE CREW COULD STATE HOW THEY WERE CHECKED FOR ACCURACY.
Recommendation: 7.5.2.2.3 A warewashing machine shall be provided with an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operating specifications including the: (1) Temperatures required for washing, rinsing, and sanitizing; (2) Pressure required for the fresh water sanitizing rinse; and (3) Conveyor speed for conveyor machines or cycle time for stationary rack machines.
Item No.: 22
Site: Other-AFT POT WASH
Violation: THE TEMPERATURE GAUGE FOR THE 3-COMPARTMENT SINK WAS 6° OUT OF CALIBRATION.
Recommendation: 7.5.2.1.1 Water temperature measuring devices: (1) That are scaled in Celsius or dually scaled in Celsius and Fahrenheit shall be designed to be accurate to ±1.5°C in the intended range of use. (2) That are scaled only in Fahrenheit shall designed to be accurate to ±3°F in the intended range of use.
Item No.: 20
Site: Other-BUFFET PANTRY
Violation: SOFT SEALANT WAS NOTED ON THE BACK PLATE OF THE SLICER. SOME FOOD RESIDUE WAS NOTED UNDER THE SEALANT. THE SEALANT SHALL BE REPLACED WITH A HARD, EASILY CLEANABLE SEALANT.
Recommendation:
Item No.: 33
Site: Other-FOOD SERVICE-GENERAL
Violation: THE POURED DECK COVERINGS THROUGHOUT THE SHIP WERE IN POOR REPAIR.
Recommendation: 7.7.4.2.3 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair.
Item No.: 33
Site: Other-TOPSIDERS - BUFFET LINE
Violation: THE JUNCTURE WHERE THE DECK AND THE CABINETS MEET WAS NOT COVED.
Recommendation: 7.7.4.1.3 Bulkhead and deck junctures shall be coved.
Item No.: 33
Site: Other-LIDO HOT GALLEY
Violation: PEELING PAINT WAS NOTED IN THE SCUPPERS.
Recommendation: 7.7.4.2.3 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair.
Item No.: 08
Site: Other-POTABLE WATER
Violation: ENSURE THAT ALL THE SCREW CAPS IN THE BUNKER STATIONS ARE FASTENED BY A NON-CORRODING CHAIN TO AN ADJACENT BULKHEAD OR SURFACE IN SUCH A MANNER THAT THE CAP DOES NOT TOUCH THE DECK WHEN HANGING FREE.
Recommendation:
Item No.: 10
Site: Other-POOL AND SPAS
Violation: FLOW DIRECTION ARROWS SHALL BE PROVIDED ON THE PIPING IN THE POOL AND SPA PUMP ROOMS.
Recommendation:
Item No.: 10
Site: Other-SPAS
Violation: SPAS WERE NOT BEING MONITORED EVERY HOUR; HOWEVER THEY WERE BEING MONITORED EVERY TWO HOURS.
Recommendation: 6.3.2.2.2 Residual halogen logs shall be maintained with residuals measured and recorded hourly during operation.
Item No.: 01
Site: Other-MEDICAL
Violation: ENSURE THAT GASTROINTESTINAL ILLNESS REPORTING IS CONDUCTED BETWEEN 24-30 HOURS PRIOR TO ARRIVING AT A U.S PORT.
Recommendation:
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program