Cruise Ship: The World Cruise Line: ResidenSea Inspection Date: 09/07/2002 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: *
Site: Other-GENERAL - COMMENT
Violation: THE OVERALL OPERATIONS OF THE VESSEL INCLUDING FOOD SERVICE, POTABLE WATER, SWIMMING POOLS AND SPAS WAS OUTSTANDING. THE OFFICERS AND CREWS ARE COMMENDED FOR THEIR HARD WORK.
Recommendation:
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation:
Recommendation: In developing the Corrective Action Statement for this inspection, critical-item deficiencies (designated with Yes in Critical Column (worth 3 - 5 points), whether debited or not, should include standard operating procedures and monitoring procedures implemented to prevent the recurrence of the critical deficiency. Prepare Corrective Action Statement as a word processing or spreadsheet file which will be sent to USPHS / VSP as an email message attachment. Please email Corrective Action Statement to: vsp@cdc.gov Use email message subject line: THE WORLD - CAS - [09-07-2002] .
Item No.: 06
Site: Other-POTABLE WATER SYSTEM
Violation: LOWER LOOP (DECKS 0 - 5) DOES NOT HAVE A HALOGEN ANALYZER RECORDER INSTALLED AT THE FAR POINT OR RETURN LINE OF THE SYSTEM. [NOTE - THIS ITEM IS UNDER TECHNICAL REVIEW AT THE TIME OF PREPARATION OF THE FINAL INSPECTION REPORT. NO ACTION IS NEEDED UNTIL REVIEW HAS BEEN COMPLETED AND FURTHER INFORMATION IS PROVIDED TO THE COMPANY BY VSP.]
Recommendation: 5.5.1.1.1 A halogen analyzer-chart recorder shall be installed at a distant point in the potable water distribution system where a significant water flow exists.
Item No.: 08
Site: Other-POTABLE WATER SYSTEM
Violation: POTABLE WATER PIPING TO HANDWASH SINK IN GARBAGE ROOM DID NOT HAVE IDENTIFICATION STRIPING. [ CORRECTED AT THE TIME OF THE INSPECTION. ]
Recommendation: 5.3.2.1.1 Potable water piping shall be painted light blue or striped with 15 cm (6 inches) light blue bands or a light blue stripe at fittings on each side of partitions, decks, and bulkheads and at intervals not to exceed 5 m (15 feet) in all spaces, except where the decor would be marred by such markings.
Item No.: 08
Site: Other-POTABLE WATER SYSTEM
Violation: BACKFLOW PREVENTION DEVICE TESTING RECORDS DID NOT SHOW PRESSURE DIFFERENCES ON BOTH SIDES OF THE VALVES.
Recommendation: 5.7.2.2.2 Backflow prevention devices requiring testing, for example reduced pressure backflow preventer and double check valves with test cocks, shall be inspected and tested with a test kit at least annually. Test results showing the pressure differences on both sides of the valves shall be maintained for each device.
Item No.: 08
Site: Other-TIDES RESTAURANT
Violation: ONE BACKFLOW PREVENTER TO THE COFFEE MACHINE WAS LEAKING AT THE AIR RELIEF HOLES. [ CORRECTED AT THE TIME OF THE INSPECTION. ]
Recommendation:
Item No.: 20
Site: Other-TIDES - GALLEY
Violation: SLIGHT SURFACE CORROSION WAS NOTED ON THE INTERIOR OF AN ICE MACHINE.
Recommendation: 7.4.5.1.1.1 Food-contact equipment shall be maintained in good repair and proper adjustment including: (1) Equipment shall be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines.
Item No.: 22
Site: Other-MARINA BAR / PANTRY
Violation: THERE WAS A SPONGE IN THE SANITIZE BUCKET.
Recommendation: 7.5.5.5.2 Sponges may not be used in contact with cleaned and sanitized or in-use food-contact surfaces.
Item No.: 22
Site: Other-FOOD SERVICE - GENERAL
Violation: THIN SPONGE TYPE WIPING CLOTHS WERE NOTED IN NUMEROUS SANITIZE BUCKETS. IF THESE WIPING CLOTHS ARE DISCARDED DAILY THEY ARE ACCEPTABLE.
Recommendation: 7.5.5.5.2 Sponges may not be used in contact with cleaned and sanitized or in-use food-contact surfaces. Replace the thin wiping sponges daily or replace them with cloths.