Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Silver Cloud Cruise Line: Silversea Inspection Date: 12/22/2002 Inspection Score: 96
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 33
Site: Other-FOOD SERVICE GENERAL
Violation: THE FLOOR SCUPPERS LOCATED IN THE SOUP KETTLE AREAS WERE DIFFICULT TO CLEAN DUE TO CORROSION AND PEELING PAINT.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 15
Site: Other-PROVISIONS
Violation: A FEW DENTED CANS WERE NOTED IN THE DRY STORES ROOM.
Recommendation: 7.3.2.2.5 Food packages shall be in good condition and protect the integrity of the contents so that the food is not exposed to adulteration or potential contaminants. Canned goods with dents on end or side seams may not be used.
Item No.: 21
Site: Other-FOOD SERVICE GENERAL
Violation: THE OLDER PIECES OF GALLEY EQUIPMENT WERE DIFFICULT TO CLEAN DUE TO CREVICES, OPEN SEAMS AND GAPS.
Recommendation: 7.4.2.2.6 Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Other-MAIN GALLEY - HOT LINE
Violation: FOOD AND GREASE RESIDUE WAS NOTED IN THE OPEN SEAMS OF THE FLAT TOP LANG GRILL.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 22
Site: Other-MAIN GALLEY - DISHWASH
Violation: THE FINAL RINSE NOZZLES HAD AN ERRATIC SPRAY PATTERN.
Recommendation: Unclog the final rinse nozzles.
Item No.: 22
Site: Other-MAIN GALLEY - DISHWASH
Violation: THE FINAL RINSE PRESSURE ON THE FLIGHT TYPE DISHWASH MACHINE WAS TOO HIGH. STEAM WAS NOTED COMING OUT OF THE FINAL RINSE NOZZLES.
Recommendation: Adjust the pressure on the final rinse water line.
Item No.: 22
Site: Other-CREW GALLEY - DISHWASH
Violation: THE CURTAIN WAS MISSING BETWEEN THE WASH AND FINAL RINSE COMPARTMENT OF THE FLIGHT TYPE DISHWASH MACHINE.
Recommendation: 7.5.2.2.4 Warewashing machine wash and rinse tanks shall be equipped with baffles, curtains, or other means to minimize internal cross-contamination of the solutions in wash and rinse tanks.
Item No.: 36
Site: Other-TERRACE CAFÉ
Violation: THE BULBS IN THE HEAT LAMPS WERE NOT PROPERLY SHIELDED AND THEY WERE NOT SHATTER-RESISTANT BULBS.
Recommendation: 7.7.5.2.1 Light bulbs shall be shielded, coated, or otherwise shatter-resistant in areas where there is exposed food; clean equipment, utensils, and linens; or unwrapped single-service, and single-use articles. 7.7.5.2.2 An infrared or other heat lamp shall be protected against breakage by a shield surrounding and extending beyond the bulb so that only the face of the bulb is exposed.
Item No.: 10
Site: Other-POOLS
Violation: THERE WAS NO SHEPHERD'S HOOK PROVIDED BY THE POOL.
Recommendation: 6.4.1.2.1 Easy access shepherd's hook shall be provided at a prominent location near each public swimming pool.
Item No.: 08
Site: Other-POTABLE WATER
Violation: REDUCED PRESSURE BACKFLOW ASSEMBLIES WERE NOT INSTALLED ON THE INTERNATIONAL SHORE CONNECTIONS.
Recommendation: 5.7.1.1.3 The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
Item No.: 33
Site: Other-PANORAMIC BAR
Violation: OPEN PIPE PENETRATIONS WERE NOTED UNDERNEATH THE BAR COUNTER.
Recommendation: 7.7.4.1.7 Exposed utility service lines and pipes, including lines for fire detection and protection systems, shall be installed so they do not obstruct or prevent cleaning.
Item No.: 41
Site: Other-VENTILATION UNITS
Violation: STANDING WATER WAS NOTED IN THE DRAIN PANS OF THE VENTILATION SYSTEMS.
Recommendation: 9.2.1.1.2 Air condition condensation collection pans shall be self-draining.
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
Recommendation:
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program