|
|
|
Item No.:
08
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
THERE WAS NO REDUCED PRESSURE BACKFLOW ASSEMBLY INSTALLED ON EITHER OF THE INTERNATIONAL SHORE CONNECTIONS.
|
|
Recommendation:
Install the appropriate reduced pressure backflow assembly on the international shore connections.
|
|
|
Item No.:
06
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
THE HALOGEN ANALYZER-CHART RECORDER CHARTS DID NOT HAVE A RANGE OF 0.0 TO 5.0 PPM. THE CHARTS BEING USED HAD A RANGE OF 0.0 TO 100 PPM.
|
|
Recommendation:
5.5.2.1.1
Halogen analyzer-chart recorder charts shall have a range of 0.0 to 5.0 mg/L (ppm) and have a recording period of 24 hours.
|
|
|
Item No.:
*
|
|
Site:
Other-CORRECTIVE ACTION STATEMENT
|
|
Violation:
IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY.
PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV
USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
|
|
Recommendation:
|
|
|
Item No.:
37
|
|
Site:
Other-TOP SIDE RESTAURANT-PANTRY # 5
|
|
Violation:
EXCESSIVE CONDENSATION BUILDUP WAS NOTED ON THE DECKHEAD OVER THE WAREWASHER AND ON THE VENTILATION VENT.
|
|
Recommendation:
7.4.3.2.1
Ventilation hood systems and devices shall be sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
|
|
|
Item No.:
37
|
|
Site:
Other-TOP SIDE RESTAURANT-HOT GALLEY
|
|
Violation:
THE AREA WAS EXCESSIVELY HOT AND HUMID. THE EMPLOYEE WORKING IN THE SPACE WAS PERSPIRING PROFUSELY. THIS ITEM WAS CITED ON THE LAST INSPECTION.
|
|
Recommendation:
7.7.6.1.1
All food preparation, warewashing, and toilet rooms shall have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes.
|
|
|
Item No.:
33
|
|
Site:
Other-TOP SIDE RESTAURANT
|
|
Violation:
THE JUNCTURE WHERE THE DECK JOINS THE BULKHEAD IN THE HOT AND COLD PANTRY SECTIONS WAS EITHER NOT COVED OR SMALL SECTIONS WHERE COVED WITH A SOFT SEALANT. THE FRONT COUNTER AND DECK JUNCTURE WAS NOT COVED ON THE PASSENGER SIDE OF THESE SERVICE SECTIONS.
|
|
Recommendation:
7.7.4.1.3
Bulkhead and deck junctures shall be coved.
|
|
|
Item No.:
*
|
|
Site:
Other-TOP SIDE RESTAURANT -COLD SIDE BUFFET
|
|
Violation:
IT IS RECOMMENDED THAT CRUSHED ICE BE USED FOR THE DISPLAY OF FOOD ITEMS ON THE COLD BUFFET LINE TO ENSURE THAT THE FOOD CONTAINERS CAN BE EASILY SUBMERGED INTO THE ICE TO MAINTAIN PROPER COOLING FOR THE FOOD ITEMS.
|
|
Recommendation:
|
|
|
Item No.:
26
|
|
Site:
Other-GALLEY-POTWASH
|
|
Violation:
A COUPLE OF SOILED POTS WERE STORED AS CLEAN.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
20
|
|
Site:
Other-FOOD SERVICE GENERAL
|
|
Violation:
SEVERAL CUTTING BOARDS WERE FOUND SCRATCHED AND PITTED. IT WAS NOTED THAT SOME BOARDS ARE BEING SANDED BUT STILL DID NOT HAVE A SMOOTH SURFACE FOR EASY CLEANING.
|
|
Recommendation:
7.4.5.1.3
Surfaces such as cutting blocks and boards that are subject to scratching and scoring shall be resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
|
|
|
Item No.:
21
|
|
Site:
Other-TOY OF YACHT-BAR PANTRY
|
|
Violation:
THE ICE MACHINE DOOR WAS NOT FUNCTIONING PROPERLY MAKING OPENING THE DOOR VERY DIFFICULT.
|
|
Recommendation:
Fix the ice machine door.
|
|