|
|
|
Item No.:
*
|
|
Site:
Other-CORRECTIVE ACTION STATEMENT
|
|
Violation:
IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY.
PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV
USE EMAIL MESSAGE SUBJECT LINE: SEVEN SEA MARINER - CAS - [01/07/2003] .
|
|
Recommendation:
|
|
|
Item No.:
02
|
|
Site:
Other-MEDICAL
|
|
Violation:
A PATIENT WAS DISPENSED ANTIDIARRHEAL MEDICATION BUT WAS NOT ENTERED IN THE GASTROINTESTINAL ILLNESS LOG AS REQUIRED.
|
|
Recommendation:
4.1.2.1.3
The log shall list:
(1) All reportable cases of gastrointestinal illness; (2) All passengers and crew members who are dispensed antidiarrheal medication from the master of the vessel, the medical staff, or other designated staff.
|
|
|
Item No.:
08
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
THE COMPREHENSIVE CROSS CONNECTION CONTROL PROGRAM DID NOT LIST ALL OF THE DEVICES IN THE GALLEYS, AND WAREWASHING AREAS.
|
|
Recommendation:
5.7.1.1.3
The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present:
(1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
|
|
|
Item No.:
09
|
|
Site:
Other-WHIRLPOOL SPAS
|
|
Violation:
A REVIEW OF THE CHARTS NOTED A FEW DAYS WHERE THE BROMINE RESIDUAL WAS NOT KEPT AT 4 PPM OR HIGHER.
|
|
Recommendation:
6.3.2.1.1
Whirlpool spas shall maintain a free residual chlorine of >3.0 mg/L (ppm) and <10 mg/L (ppm), or a free residual bromine of >4.0 mg/L (ppm) and <10 mg/L (ppm).
|
|
|
Item No.:
41
|
|
Site:
Other-VENTILATION
|
|
Violation:
THE CONDENSATE COLLECTION SYSTEM AND DRAIN PANS WERE NOT ACCESSIBLE FOR INSPECTION.
|
|
Recommendation:
9.2.1.1.1
Air handling unit condensate drain pans and collection systems shall be accessible for inspection, maintenance, and cleaning.
|
|
|
Item No.:
38
|
|
Site:
Other-COMPASS ROSE DINING ROOM
|
|
Violation:
THE MOP WAS STORED IN THE BUCKET IN THE FOYER LEADING TO THE GALLEY.
|
|
Recommendation:
7.7.7.1.4
After use, mops shall be placed in a position that allows them to air-dry without soiling walls, equipment, or supplies.
7.7.7.1.3
Maintenance tools such as mops, brooms, and similar items shall be stored in an orderly manner that facilitates cleaning of the area used for storing the maintenance tools.
|
|
|
Item No.:
28
|
|
Site:
Other-MAIN GALLEY-DISHWASH-STARBOARD
|
|
Violation:
THE PLATE COVERS WERE NOT STORED INVERTED.
|
|
Recommendation:
7.5.7.3.2
Clean equipment and utensils shall be stored:
(1) In a self-draining position that allows air drying; and (2) Covered or inverted.
|
|
|
Item No.:
22
|
|
Site:
Other-CREW DISHWASH
|
|
Violation:
THE FINAL RINSE SPRAY PATTERN WAS POOR. THE PRESSURE WAS LESS THAN 10 PSI. THE FINAL RINSE TEMPERATURE WAS TESTED AT 170°F AT THE PLATE LEVEL.
|
|
Recommendation:
7.5.4.1.3
A warewashing machine and its auxiliary components:
(1) Shall be operated in accordance with the machine's data plate and other manufacturer's instructions. (2) A warewashing machine's conveyor speed or automatic cycle times shall be maintained accurately timed in accordance with manufacturer's specifications.
7.5.6.1.3
The flow pressure of the fresh hot water sanitizing rinse in a warewashing machine may not be less than 100 kilopascals (15 pounds per square inch) or more than 170 kilopascals (25 pounds per square inch) as measured in the water line immediately downstream or upstream from the fresh hot water sanitizing rinse control valve.
|
|
|
Item No.:
27
|
|
Site:
Other-POOL GRILL
|
|
Violation:
FOOD DEBRIS WAS NOTED IN THE GRILL DRIP PAN HOUSINGS.
|
|
Recommendation:
7.5.5.1.3
Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|