Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: AIDAVITA Cruise Line: Aida Cruises Inspection Date: 11/14/2002 Inspection Score: 98
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
Recommendation:
Item No.: 10
Site: Other-SPA'S
Violation: THE SPA'S WERE NOT BEING MONITORED EVERY HOUR FOR THEIR FREE RESIDUAL HALOGEN LEVEL.
Recommendation: Ensure that spas are monitored every hour for free residual halogen.
Item No.: 10
Site: Other-POOLS AND SPA'S
Violation: THERE WAS NO WRITTEN FECAL ACCIDENT RESPONSE PLAN.
Recommendation: 6.1.2.2.2 A fecal accident response procedure shall be documented and available for review during inspections.
Item No.: 19
Site: Other-MARKET RESTAURANT DECK #8
Violation: OPEN BASKETS OF BREAD WERE STORED ABOVE THE SHIELDED FOOD SERVICE LINE WITHOUT BEING SHIELDED. THE FOOD SERVICE LINE WAS NOT IN OPERATION AT THE TIME OF THE INSPECTION.
Recommendation: 7.3.3.6.1 Food on display shall be protected from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; or other effective means.
Item No.: 19
Site: Other-CALYPSO RESTAURANT DECK#9
Violation: OPEN BASKETS OF BREAD WERE STORED ABOVE THE SHIELDED FOOD SERVICE LINE WITHOUT BEING SHIELDED. THE FOOD SERVICE LINE WAS NOT IN OPERATION AT THE TIME OF THE INSPECTION.
Recommendation: 7.3.3.6.1 Food on display shall be protected from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; or other effective means.
Item No.: 20
Site: Other-MARKET RESTAURANT DECK #8
Violation: THE CUTTING BOARD AT THE BREAD STATION WAS MADE OF WOOD WHICH DOES NOT PROVIDE A EASILY CLEANABLE AND DURABLE SURFACE.
Recommendation: Replace the wooden cutting boards with cutting boards that are durable and easily cleanable.
Item No.: 20
Site: Other-FOOD SERVICE GENERAL
Violation: CUTTING BOARDS THROUGHOUT THE SHIP WERE PITTED AND HEAVILY SCORED.
Recommendation: 7.4.5.1.3 Surfaces such as cutting blocks and boards that are subject to scratching and scoring shall be resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
Item No.: 21
Site: Other-BUTCHER SHOP DECK # 3
Violation: SOFT SEALANT WAS NOTED ON THE SEAMS OF THE MEAT CUTTING MACHINE.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 22
Site: Other-LIDO - DISHWASH
Violation: THE TEMPERATURE GAUGES ON THE DISHWASH MACHINE WERE NOT WORKING.
Recommendation: 7.5.4.1.1 Warewashing equipment shall be maintained in good repair and proper adjustment including: Water pressure, and water temperature measuring devices shall be maintained in good repair and be accurate within the intended range of use.
Item No.: 28
Site: Other-LIDO - BUFFET SERVICE LINE
Violation: NOT ALL THE PLATES AND BOWLS ON THE BUFFET SERVICE LINES WERE STORED INVERTED.
Recommendation: 7.5.7.3.2 Clean equipment and utensils shall be stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
Item No.: 28
Site: Other-CALYPSO RESTAURANT DECK #9
Violation: PLATES WERE NOT STORED INVERTED AT THE FOOD SERVICE LINE TO PROTECT AGAINST CONTAMINATION. THE SERVICE LINE WAS NOT IN USE AT THE TIME OF THE INSPECTION.
Recommendation: 7.5.7.3.2 Clean equipment and utensils shall be stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
Item No.: 28
Site: Other-MARKET RESTAURANT DECK #8
Violation: PLATES WERE NOT STORED INVERTED AT THE FOOD SERVICE LINE TO PROTECT AGAINST CONTAMINATION. THE SERVICE LINE WAS NOT IN USE AT THE TIME OF THE INSPECTION.
Recommendation: 7.5.7.3.2 Clean equipment and utensils shall be stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
Item No.: 40
Site: Other-INTEGRATED PEST MANAGEMENT PLAN
Violation: THERE WAS NO WRITTEN INTEGRATED PEST MANAGEMENT PLAN.
Recommendation: 8.1.1.1.1 Each vessel shall develop an Integrated Pest Management Plan to address effective monitoring and control strategies for pests aboard the vessel. 8.1.1.1.3 The Integrated Pest Management Plan shall include provisions for active monitoring including pest sighting logs for the operational areas of the vessel and training for crew members in charge of log completion. 8.1.1.1.2 The Integrated Pest Management Plan shall set a schedule for periodic monitoring inspections including some at night. 8.1.1.1.4 The Integrated Pest Management Plan shall include passive surveillance procedures such as glue traps and other monitoring tools, as well as location of each. A monitoring log on passive surveillance procedures shall be maintained.
Item No.: 41
Site: Other-CHILD CARE CENTER
Violation: THERE WAS NO SIGN TO REMIND STAFF TO WASH THEIR HANDS AFTER ASSISTING CHILDREN WITH TOILET FACILITIES.
Recommendation: 10.1.1.1.3 Signs shall be posted in the diaper-changing area advising child-activity center staff to wash their hands after each diaper they change.
Item No.: 41
Site: Other-CHILD CARE CENTER
Violation: A CHILD SIZE TOILET SEAT INSERT IS NEEDED FOR THE CHILDREN'S TOILET.
Recommendation: 10.2.1.1.1 Child-size toilet seat insert shall be provided, if toilet rooms are located in a child-activity center.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program