Cruise Ship: Seadream I Cruise Line: Sea Dream Yacht Club Inspection Date: 11/16/2002 Inspection Score: 93
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 20
Site: Other-MAIN GALLEY / CLEAN POT STORAGE AREA
Violation: THE NON-STICK SURFACE OF ONE OF THE SKILLETS WAS IN POOR CONDITION AND WAS PEELING OFF.
Recommendation: Replace the skillet.
Item No.: 29
Site: Other-MAIN BAR AND PIANO BAR
Violation: THE HANDWASHING STATION FOR EACH OF THESE BARS WAS LOCATED IN THE PANTRIES. THIS REQUIRED PASSING THROUGH NORMALLY CLOSED DOORS WITH HANDLES.
Recommendation: Provide access to the handwashing stations so bar tenders do not have to touch the door handles.
Item No.: 20
Site: Other-FOOD SERVICE - GENERAL
Violation: THE FOOD CONTACT SURFACES OF OLDER EQUIPMENT SUCH AS REFRIGERATORS HAD EXPOSED WIRES, COOLING COILS AND OTHER DIFFICULT TO CLEAN FEATURES.
Recommendation: 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 21
Site: Other-FOOD SERVICE - GENERAL
Violation: THE NON-FOOD CONTACT SURFACES OF THE OLDER EQUIPMENT HAD DIFFICULT TO CLEAN FEATURES SUCH AS GAPS, SEAMS AND HOLES.
Recommendation: 7.4.2.2.6 Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 33
Site: Other-FOOD SERVICE - GENERAL
Violation: THE DECKS IN THE MAIN GALLEY, THE BULKHEADS AND DECKHEADS IN THE OLDER FOOD AREAS HAD OPEN SEAMS, EXPOSED PIPING AND WIRING AND OTHER DIFFICULT TO CLEAN FEATURES.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning. 7.7.4.1.7 Exposed utility service lines and pipes, including lines for fire detection and protection systems, shall be installed so they do not obstruct or prevent cleaning.
Item No.: *
Site: Other-GENERAL COMMENT
Violation: THE OWNER, OFFICERS AND CREW ARE COMMENDED FOR ALL OF THE WORK THAT HAS BEEN DONE TO IMPROVE THE OVERALL CONDITION OF THE VESSEL.
Recommendation:
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
Recommendation:
Item No.: 08
Site: Other-POTABLE WATER
Violation: DOUBLE CHECK VALVE ASSEMBLIES WERE INSTALLED ON THE INTERNATIONAL SHORE CONNECTIONS BUT THE OPERATIONS MANUAL REQUIRES THE INSTALLATION OF REDUCED PRESSURE PRINCIPLE (RP) ASSEMBLY BACKFLOW PREVENTERS WHICH HAVE INTERMEDIATE ATMOSPHERIC VENTS BE INSTALLED. THE DOUBLE CHECK ASSEMBLIES WERE INSTALLED AFTER THE LAST VSP INSPECTION.
Recommendation: Install reduced pressure principle assembly backflow preventers on the international shore connections.
Item No.: 21
Site: Other-MAIN GALLEY / COFFEE STATION
Violation: THE CAPPUCCINO MACHINE INSTALLED IN THIS AREA WAS NOT INSTALLED ON LONG ENOUGH LEGS TO PROVIDE ACCESS FOR CLEANING.
Recommendation: 7.4.4.1.2 Table-mounted equipment that is not easily movable shall be installed to allow cleaning of the equipment and areas underneath and around the equipment by being: (1) Sealed to the table; or (2) Elevated on legs; because of the size the minimum clearance is four inches.
Item No.: 21
Site: Other-MAIN GALLEY / HOT GALLEY
Violation: THERE WAS A DIFFICULT TO CLEAN GAP BETWEEN THE NEWLY INSTALLED STEAM KETTLE AND THE ADJACENT UNDERCOUNTER REFRIGERATION UNIT.
Recommendation: 7.4.4.1.1 Equipment that is fixed because it is not easily movable shall be installed so that it is: (1) Spaced to allow access for cleaning along the sides, behind, under and above the equipment; (2) Spaced from adjoining equipment, bulkhead, and deckhead at a distance of not more than 1 millimeter or 1/32 inch; or (3) Sealed to adjoining equipment or bulkhead, if the equipment is exposed to spillage or seepage.
Item No.: 26
Site: Other-MAIN GALLEY / POT WASH AREA
Violation: NUMEROUS PREVIOUSLY CLEANED SHEET PANS AND SMALL SKILLETS WERE FOUND SOILED WITH FOOD RESIDUE.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 22
Site: Other-MAIN GALLEY / POT WASH AREA
Violation: THE POT WASH AREA HAS BEEN CONVERTED INTO A CLEAN POT STORAGE AREA WITH ONLY THE SANITIZE SINK REMAINING BUT NOT BEING USED. POT SCRUBBING IS DONE IN THE DISHWASH AREA BUT THERE IS ONLY AN OVERHEAD SPRAY AND NO SINK. THEN THE POTS AND PANS ARE RUN THROUGH THE DISHWASHING MACHINE TO COMPLETE THE WASHING AND TO SANITIZE THE ITEMS. THIS PROCEDURE MAKES IT DIFFICULT TO REMOVE ALL OF THE FOOD RESIDUE AND MAKES SOAKING HEAVILY SOILED POTS AND PANS ALMOST IMPOSSIBLE. THE SPACE FOR DISHWASHING, POT WASHING AND STORAGE IS VERY LIMITED BUT CONSIDERATION SHOULD BE MADE FOR SOAKING HEAVILY SOILED COOKWARE.
Recommendation: Provide facilities for proper pot and pan washing.
Item No.: 36
Site: Other-MAIN GALLEY / GARDE MANGER AREA
Violation: THE LIGHT LEVEL IN FRONT OF REACH-IN REFRIGERATOR #22 WAS VERY LOW AND THERE WERE NO LIGHTS INSIDE THE REFRIGERATOR. THIS MADE IT VERY DIFFICULT TO SEE THE INSIDE OF THE UNIT TO ENSURE PROPER CLEANING.
Recommendation: 7.7.5.1.1 The light intensity shall be at least 220 Lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 36
Site: Other-MAIN GALLEY / SOILED DISH AREA
Violation: THE LIGHT LEVEL OVER THE DROP-OFF AREA WAS VERY LOW.
Recommendation: 7.7.5.1.1 The light intensity shall be at least 220 Lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
*Inspections scores of 85 or lower are NOT satisfactory