Cruise Ship: Borealis Cruise Line: Fred Olsen Cruise Line Inspection Date: 11/20/2002 Inspection Score: 97
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: *
Site: Other-POTABLE WATER AND POOLS
Violation: THE ENTIRE ENGINEERING STAFF IS COMMENDED FOR EXCELLENT RECORD KEEPING AND KNOWLEDGE OF THE ONGOING SANITATION AND MAINTENANCE OF THE VESSEL.
Recommendation:
Item No.: 21
Site: Other-LIDO PANTRY STARBOARD
Violation: THE SEAMS ON THE GAYLORD SERVICE PANEL OVER THE GRILL WERE SEALED WITH A SOFT SEALANT.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 21
Site: Other-LIDO STARBOARD
Violation: THE TOASTER OVEN HAD SEAMS THAT WERE FILLED WITH A SOFT SEALANT.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 21
Site: Other-LIDO PORTSIDE
Violation: THE SEAMS ON THE GAYLORD SERVICE PANEL OVER THE GRILL WERE FILLED WITH A SOFT SEALANT.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 21
Site: Other-MAIN GALLEY / BAKERY PASTRY AREA
Violation: THE DOOR GASKET ON UNDERCOUNTER REFRIGERATOR 4.32A WAS TORN MAKING IT DIFFICULT TO CLEAN.
Recommendation: Replace the door gasket.
Item No.: 21
Site: Other-MAIN GALLEY / SOUP AREA
Violation: THE DOOR GASKET ON UNDERCOUNTER REFRIGERATOR 4.13B WAS TORN MAKING IT DIFFICULT TO CLEAN.
Recommendation: Replace the gasket.
Item No.: 21
Site: Other-MAIN GALLEY / ROOM SERVICE AREA
Violation: THE POTABLE WATER SUPPLY LINE TO THE COFFEE MACHINES WAS MOUNTED ON THE COUNTER BEHIND THE MACHINES. THIS INSTALLATION DID NOT ALLOW ACCESS UNDER THE LINE FOR CLEANING.
Recommendation: Raise the potable water line off of the counter to allow for proper cleaning.
Item No.: 24
Site: Other-LIDO POTWASH
Violation: ENSURE THAT ALL POTS AND PANS ARE SUBMERGED AT LEAST 7 SECONDS IN THE SANITIZING RINSE BATH.
Recommendation: 7.5.6.2.2 A chemical sanitizer shall be used in accordance with the EPA-approved manufacturer's label use instructions at a minimum temperature of 24°C (75°F) with an exposure time of 7 seconds for a chlorine solution and 30 seconds for other chemical sanitizers.
Item No.: 27
Site: Other-MAIN GALLEY / LIDO PREPARATION
Violation: THE BACK OF THE SLICER WAS SOILED WITH FOOD RESIDUE. IT WAS STATED THAT THE SLICER HAD BEEN CLEANED AND SANITIZED.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Other-MAIN GALLEY / LIDO PREPARATION
Violation: THERE WAS A LOOSE BULKHEAD PROFILE BETWEEN THE WINE STATION AND THE LIDO PREPARATION MAKING THE AREA DIFFICULT TO CLEAN.
Recommendation: Reattach the loose profile.
Item No.: 33
Site: Other-PROVISIONS AREA / DRY STORAGE #6
Violation: WATER WAS NOTED DRIPPING FROM A SEAM IN THE DECKHEAD. IT APPEARED THAT IT MAY BE FROM A FIRE SPRINKLER LINE.
Recommendation: Repair the leak.
Item No.: 33
Site: Other-PROVISIONS - GENERAL
Violation: THE BULKHEADS, DOOR FRAMES AND DECKHEADS IN THE PROVISIONS AREA HAD OPENS SEAMS LOOSE PROFILES, AND GAPS MAKING THE AREA DIFFICULT TO CLEAN.
Recommendation: 7.7.4.2.3 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair.
Item No.: 33
Site: Other-FOOD SERVICE - GENERAL
Violation: THE DECKS THROUGHOUT THESE AREAS HAD CRACKED TILES AND RECESSED GROUTING. NUMEROUS AREAS HAD BEEN REPAIRED AND THE OTHER AREAS ARE SCHEDULED FOR REPAIR.
Recommendation:
Item No.: 33
Site: Other-MAIN GALLEY / LIDO PREPARATION
Violation: THERE WAS A LOOSE BULKHEAD PROFILE NEAR THE SLICER THAT MADE THE AREA DIFFICULT TO CLEAN.
Recommendation: Reattach the profile.
Item No.: 33
Site: Other-MAIN GALLEY / BEVERAGE LINE
Violation: THE DRAIN LINE FROM ONE OF THE WMF COFFEE MACHINES WAS LAYING ON THE DECK MAKING THE AREA DIFFICULT TO CLEAN AND THERE WAS COFFEE GROUNDS AND OTHER DEBRIS IN THIS AREA.
Recommendation: Raise the drain line off of the deck to provide access for cleaning.
Item No.: 33
Site: Other-LIDO SERVICE AREAS
Violation: THE TILE WAS CHIPPED AND CRACKED THROUGHOUT THE LIDO.
Recommendation: 7.7.4.2.3 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair.
Item No.: 34
Site: Other-MAIN GALLEY / BEVERAGE LINE
Violation: THE DRAIN LINES OF THE WMF COFFEE MACHINES WERE NOT DRAINING CORRECTLY AND HAD SOILED THE INTERIORS OF THE TECHNICAL CABINETS WITH COFFEE GROUNDS.
Recommendation: Correct the drainage problems.