Cruise Ship: Silver Whisper Cruise Line: Silversea Inspection Date: 11/17/2002 Inspection Score: 92
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 16
Site: Other-FOOD SERVICE GENERAL
Violation: THE DOCUMENTION FROM THE FISH SUPPLIER STATED THAT THE FISH WAS FROZEN TO 0°F. THERE WAS NO INDICATION OF THE TIME THE FISH WAS HELD AT THAT TEMPERATURE. 0°F IS NOT COLD ENOUGH TO DESTROY PARASITES. THE TUNA USED FOR THE SUSHI WAS SAID TO BE "SOCK EYE TUNA". THIS IS NOT A SPECIES OF TUNA EXEMPT FROM THE FREEZING REQUIREMENT. THE LACK OF DOCUMENTATION ON THE FREEZING FOR PARASITE DESTRUCTION OF THE SALMON THAT WAS SERVED RAW AS GRAVLAX WAS ALSO NOTED DURING THE LAST INSPECTION.
Recommendation: 7.3.4.2.1 Before service in ready-to-eat form, raw, raw-marinated, partially cooked, or marinated-partially cooked fish other than molluscan shellfish: (1) Shall be frozen throughout to a temperature of -20°C (-4°F) or below for 168 hours (7 days) in a freezer; or -35°C (-31°F) or below for 15 hours in a blast freezer. If the tuna served raw is not a species exempt from the freezing requirement the above guidelines would apply to the tuna as well as the salmon.
Item No.: 28
Site: Other-MAIN GALLEY
Violation: THE PLATES IN THE TROLLEY BY THE PORT DISHWASH AREA WERE NOT STORED COVERED OR INVERTED.
Recommendation: 7.5.7.3.2 Clean equipment and utensils shall be stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted. 7.5.7.3.2 Clean equipment and utensils shall be stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
Item No.: 22
Site: Other-MAIN GALLEY-PORT DISHWASH
Violation: THE DISHWASH UNIT WAS OUT OF ORDER.
Recommendation: Repair or replace this unit as soon as possible.
Item No.: 27
Site: Other-MAIN GALLEY
Violation: THE PLASTIC WRAP DISPENSER IN THE PORT BEVERAGE STATION WAS SOILED.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 26
Site: Other-MAIN GALLEY POT WASH
Violation: ONE SOILED STAINLESS STEEL BOWL WAS NOTED IN CLEAN STORAGE.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 28
Site: Other-MAIN GALLEY POT WASH
Violation: THE DETERGENT DISPENSER WAS MOUNTED VERY CLOSE TO THE CLEAN STORAGE RACK. SOME ITEMS WERE OVERLAPPING THE RACK PUTTING THEM CLOSER TO THE DISPENSER.
Recommendation: Move the detergent dispenser or install a splash shield to protect the clean items.
Item No.: 36
Site: Other-MAIN GALLEY
Violation: THE FACES OF THE BULBS EXTENDED BEYOND THE METAL SLEEVES OF THE HEAT LAMPS.
Recommendation: 7.7.5.2.2 An infrared or other heat lamp shall be protected against breakage by a shield surrounding and extending beyond the bulb so that only the face of the bulb is exposed.
Item No.: 31
Site: Other-BAKERY/PASTRY
Violation: BLEACH WAS STORED IN A BOTTLE LABELED GREASE CUTTER IN THE CLEANING LOCKER.
Recommendation: 7.6.1.1.2 Working containers used for storing poisonous or toxic materials such as cleaners and sanitizers taken from bulk supplies shall be clearly and individually identified with the common name of the material.
Item No.: 21
Site: Other-MAIN RESTAURANT DINING ROOM
Violation: A GAP WAS NOTED ON THE RIGHT SIDE OF THE STARBOARD WAIT-STATION AND ON THE LEFT SIDE OF THE PORT WAIT-STATION BETWEEN THE STATIONS AND THE BULKHEADS. THESE STATIONS WERE THE ONES CLOSEST TO THE GALLEY ENTRANCE.
Recommendation: INSTALL PROFILE STRIPS TO CLOSE THESE GAPS.
Item No.: 22
Site: Other-CREW POT WASH
Violation: THE MOUNTED THERMOMETER AT THE POT WASH SINK NOTED 180°F WHILE THE WATER TEMPERATURE WAS TESTED AT 208°F. THIS WAS NOTED DURING THE LAST INSPECTION. THE FINAL RINSE THERMOMETER ON THE WAREWASH UNIT NOTED 210°F DURING THE RINSE CYCLE. THIS TEMPERATURE FLUCTUATED BETWEEN 190-210°F. THE PROBE FOR THIS THERMOMETER WAS SAID TO BE LOCATED IN THE BOOSTER UNIT.
Recommendation: 7.5.2.2.5 A warewashing machine shall be equipped with a temperature measuring device that indicates the temperature of the water: (1) In each wash and rinse tank; and (2) As the water enters the hot water sanitizing final rinse manifold or in the chemical sanitizing solution tank. 7.5.2.1.1 Water temperature measuring devices: (1) That are scaled in Celsius or dually scaled in Celsius and Fahrenheit shall be designed to be accurate to ±1.5°C in the intended range of use. (2) That are scaled only in Fahrenheit shall designed to be accurate to ±3°F in the intended range of use.
Item No.: 28
Site: Other-CREW DISHWASH
Violation: THE STORED SILVERWARE WAS NOT COVERED.
Recommendation: 7.5.7.3.2 Clean equipment and utensils shall be stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
Item No.: 02
Site: Other-MEDICAL
Violation: THE STANDARDIZED GASTROINTESTINAL ILLNESS LOG DID NOT HAVE A COLUMN TO INDICATE WHETHER AN INDIVIDUAL WAS A PASSENGER OR CREW MEMBER. THE STANDARDIZED GASTROINTESTINAL ILLNESS LOG DID NOT HAVE A COLUMN TO INDICATE THE JOB OR POSITION OF EACH CREW MEMBER.
Recommendation: 4.1.2.1.4 The gastrointestinal illness surveillance log entry for each passenger or crew member shall contain the following information: (1) The first date of clinic visit or report to staff of illness; (2) The person's name, age and gender; (3) A designation as passenger or crew member; (4) Crew member position or job on the vessel, if applicable; (5) Cabin number; (6) Meal seating information; (7) Date and time of illness onset; (8) Illness symptoms, including the presence of the following selected signs and symptoms: numbers of episodes each of diarrhea and vomiting per day, bloody stools, fever, recorded temperature; (9) Notation on whether or not a stool specimen was requested and received; (10) Use of antidiarrheal medication; and (11) The presence of underlying medical conditions which may affect interpretation of acute gastrointestinal illness for example diabetic diarrhea, inflammatory bowel disease, gastrectomy or others.
Item No.: 05
Site: Other-POTABLE WATER
Violation: THE FAR POINT CHLORINE ANALYZER HAD A READING OF 1.57 PPM WHILE THE MANUAL TEST INDICATED 2.04 PPM FREE CHLORINE.
Recommendation: 5.5.1.2.3 The free residual halogen measured by the halogen analyzer shall be ±0.2 mg/L (ppm) of the free residual halogen measured by the manual test.
Item No.: 10
Site: Other-HOUSEKEEPING
Violation: THE LOG OF THE CLEANING AND DISINFECTION OF THE PRIVATE JETTED TUBS THAT WERE LOCATED IN THE SUITES INDICATED THAT THESE UNITS WERE NOT BEING DISINFECTED AT LEAST ONCE EVERY 7 DAYS FOR CRUISES THAT LAST MORE THAN 7 DAYS.
Recommendation: 6.3.3.1.1 Private whirlpool spas located in individual passenger cabins shall be cleaned and disinfected, including associated recirculation systems, between occupancies or weekly, whichever is more frequent.
Item No.: 26
Site: Other-TERRACE CAFÉ
Violation: THERE WERE SEVERAL PREVIOUSLY CLEANED SHEET PANS THAT WERE SOILED WITH FOOD RESIDUE AND STORED AS CLEAN.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 16
Site: Other-FOOD SERVICE
Violation: THERE WAS NO INDICATION THAT THE COOLING TEMPERATURE OF HOT FOODS WAS MONITORED AT THE 6-HOUR POINT TO ENSURE THAT 41° F(5°C) HAS BEEN REACHED. THE LACK OF DOCUMENTATION FOR BOTH THE 2-HOUR AND 6-HOUR COOLING POINTS WAS NOTED DURING THE LAST INSPECTION
Recommendation: 7.3.5.2.1 Cooked potentially hazardous food shall be cooled: (1) Within 2 hours, from 60°C (140°F) to 21°C (70°F); and (2) Within 4 hours, from 21°C (70°F) to 5°C (41°F) or less.
Item No.: 27
Site: Other-BEVERAGE STATION-GALLEY PORT
Violation: THE CARROT JUICE PULP BASKET CAN BE DISASSEMBLED BUT HAS NOT BEEN FOR QUITE SOME TIME. THERE WAS A LAYER OF SOAP AND FOOD RESIDUE UNDER THE BOTTOM PLATE OF THE BASKET AFTER IT WAS DISASSEMBLED.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Other-MAIN GALLEY
Violation: SEVERAL CARBOARD PLASTIC WRAP AND FOIL DISPENSERS WERE NOTED IN THE GALLEY.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 22
Site: Other-MAIN GALLEY POT WASH
Violation: A DATA PLATE WAS NOT PROVIDED AT THE POT WASH MACHINE. THE FINAL RINSE AND PRESSURE GAUGES WERE NOT FUNCTIONING PROPERLY.
Recommendation: 7.5.2.2.3 A warewashing machine shall be provided with an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operating specifications including the: (1) Temperatures required for washing, rinsing, and sanitizing; (2) Pressure required for the fresh water sanitizing rinse; and (3) Conveyor speed for conveyor machines or cycle time for stationary rack machines. 7.5.4.1.1 Warewashing equipment shall be maintained in good repair and proper adjustment including: (1) Warewashing equipment shall be maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines. (2) Water pressure, and water temperature measuring devices shall be maintained in good repair and be accurate within the intended range of use.
Item No.: 30
Site: Other-MAIN GALLEY POT WASH
Violation: A WASTE RECEPTACLE WAS NOT PROVIDED AT THE HANDWASH SINK.
Recommendation: 7.7.1.1.6 A handwashing facility shall include a sink, soap dispenser, single-use towels dispenser, and waste receptacle.
Item No.: 18
Site: Other-MAIN GALLEY
Violation: RAW LAMB WAS STORED OVER CURED HAM IN FRIDGE 1.
Recommendation: 7.3.3.2.1.1 Food shall be protected from cross-contamination by: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food including other raw animal food such as fish for sushi or molluscan shellfish, or other raw ready-to-eat food such as vegetables, and cooked ready-to-eat food; so products do not physically touch, and so as to prevent dripping of one product into another.
Item No.: 20
Site: Other-BAKERY/PASTRY
Violation: A SMALL MIXER THAT WAS NOT COMMERCIAL-GRADE WAS NOTED.
Recommendation: 7.4.2.5.1 Food-contact surfaces of food equipment shall comply with American National Standards Institute (ANSI) or other internationally accredited food-equipment sanitation standards for materials, design, and construction.
Item No.: 16
Site: Other-STARBOARD BEVERAGE STATION
Violation: THE OPEN DATE AND NOT THE DISCARD DATE WAS NOTED ON AN OPEN CONTAINER OF CREAM.
Recommendation: 7.3.5.3.2 Refrigerated, ready-to-eat, potentially hazardous food: (2) A container of refrigerated, ready-to-eat potentially hazardous food prepared and packaged by a food processing plant shall be clearly marked, at the time the original container is opened, to indicate the date by which the food shall be consumed which is, including the day the original container is opened, 7 calendar days or fewer after the original container is opened.
Item No.: 33
Site: Other-MAIN RESTAURANT DINING ROOM
Violation: DEBRIS, PAPER, AND A TRAY WERE NOTED ON THE DECK IN THE GAPS BETWEEN THE WAIT-STATIONS AND THE BULKHEADS.
Recommendation: 7.7.4.2.1 Decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, shall be cleaned as often as necessary.
Item No.: 31
Site: Other-CREW POT WASH
Violation: A BOTTLE LABELED CHLORINE SOLUTION 50-200 PPM WAS NOTED TO HAVE A SOLUTION THAT WAS IN EXCESS OF 200 PPM.
Recommendation: Properly label working bottles of santizers.
Item No.: 31
Site: Other-PROVISIONS-VEGETABLE PREPARATION
Violation: A BOTTLE LABELED CHLORINE SOLUTION WAS NOTED TO CONTAIN UNDILUTED BLEACH.
Recommendation: Properly label working bottles of sanitizers.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE VESSEL DID NOT HAVE FREE CHLORINE TEST REAGENTS ONBOARD AND WERE USING TOTAL CHLORINE REAGENTS TO CALIBRATE THE FAR POINT ANALYZER AND TO TEST THE OTHER SYSTEMS FOR CHLORINE RESIDUALS. THIS ITEM WAS NOTED ON THE LAST INSPECTION (NOVEMBER 29, 2001).
Recommendation: Ensure that free chlorine test reagents are available onboard the vessel at all times.
Item No.: 41
Site: Other-VENTILATION SYSTEM
Violation: THE CONDENSATE COLLECTION PANS WERE NOT ACCESSIBLE FOR INSPECTION. THE MAINTENANCE RECORDS DID NOT INDICATE THAT THE PANS WERE INSPECTED AND IF NECESSARY CLEANED AT LEAST ANNUALLY.
Recommendation: 9.2.1.1.1 Air handling unit condensate drain pans and collection systems shall be accessible for inspection, maintenance, and cleaning. 9.2.1.2.2 Evaporative condensers shall be inspected at least annually and cleaned as necessary to remove scale and sediment. Cooling coils and condensate pans shall be cleaned as necessary to remove dirt and organic material.
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SILVER WHISPER - CAS - [11/17/2002] .
Recommendation:
*Inspections scores of 85 or lower are NOT satisfactory