Item No.:
06
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
ENSURE THAT THE ANALYZER IS CALIBRATED DAILY.
|
|
Recommendation:
5.5.1.2.2
The calibration shall be recorded on the chart or in a log book.
|
|
|
Item No.:
08
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
A CROSS CONNECTION CONTROL PLAN WAS NOT PROVIDED FOR THE POTABLE WATER SYSTEM.
|
|
Recommendation:
5.7.1.1.3
The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present:
(1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
|
|
|
Item No.:
08
|
|
Site:
Other-DECK TAPS
|
|
Violation:
IF HOSES WITH NOZZLES ARE ATTACHED TO THE DECK TAPS THEN CONTINUOUS PRESSURE BACKFLOW PREVENTERS NEED TO BE INSTALLED.
|
|
Recommendation:
Install the appropriate continuous backflow preventers on these deck taps.
|
|
|
Item No.:
40
|
|
Site:
Other-INTEGRATED PEST MANAGEMENT PLAN
|
|
Violation:
PROVIDE DOCUMENTATION FOR CREW THAT WERE TRAINED ONBOARD THE VESSEL.
|
|
Recommendation:
8.1.2.1.3
The training of the pest-control personnel shall be documented in the Integrated Pest Management Plan.
|
|
|
Item No.:
41
|
|
Site:
Other-HOUSEKEEPING
|
|
Violation:
HOUSEKEEPING PROCEDURES ARE IN PLACE HOWEVER THEY DO NOT REFLECT THE CURRENT LEVEL THAT IS NEEDED AGAINST NORWALK TYPE VIRUS.
|
|
Recommendation:
9.1.1.1.1
When the cumulative proportion of cases of gastrointestinal illness among passengers or crew members is 2%, the infection control response shall include cleaning and disinfecting all public areas, including handrails and restrooms, on a continuous basis until the proportion decreases to <2%.
|
|
|
Item No.:
*
|
|
Site:
Other-CORRECTIVE ACTION STATEMENT
|
|
Violation:
IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY.
PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV
USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
|
|
Recommendation:
|
|
|
Item No.:
26
|
|
Site:
Other-GALLEY
|
|
Violation:
NUMEROUS POTS AND PANS, A MESH STRAINER, A VEGETABLE PEELER, NUMEROUS PLATES, A HAND MIXER, AND A KNIFE STORED AS CLEAN WERE SOILED WITH FOOD RESIDUE.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
20
|
|
Site:
Other-GALLEY
|
|
Violation:
ONE CUTTING BOARD WAS FOUND PITTED AND SCRATCHED.
|
|
Recommendation:
7.4.5.1.3
Surfaces such as cutting blocks and boards that are subject to scratching and scoring shall be resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
|
|
|
Item No.:
33
|
|
Site:
Other-GALLEY
|
|
Violation:
CORROSION AND GAPS WERE NOTED ON THE DECKHEAD.
|
|
Recommendation:
7.7.4.1.5
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be corrosion-resistant.
|
|
|
Item No.:
20
|
|
Site:
Other-GALLEY
|
|
Violation:
GAPS WERE NOTED BETWEEN THE HANDLE AND THE BLADE OF ONE CHOPPER. THE HANDLE WAS MADE OF UNFINISHED WOOD.
|
|
Recommendation:
7.4.1.1.2
Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be:
(1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
|
|
|
Item No.:
08
|
|
Site:
Other-GALLEY
|
|
Violation:
A BACKFLOW PREVENTION DEVICE WAS MISSING ON THE FAUCET OVER THE RANGE AREA. IT WAS STATED THAT THIS FAUCET IS NOT USED. IT IS RECOMMENDED THAT THIS FAUCET BE REMOVED IF IT IS NOT IN USE.
|
|
Recommendation:
Install the appropriate backflow device.
|
|
|
Item No.:
27
|
|
Site:
Other-GALLEY
|
|
Violation:
A FEW DRAWERS USED TO STORED FOOD CONTACT EQUIPMENT WERE SOILED WITH FOOD RESIDUE.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Other-GALLEY
|
|
Violation:
THE INTERIOR OF THE MICROWAVE WAS SOILED WITH FOOD RESIDUE.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
31
|
|
Site:
Other-GALLEY
|
|
Violation:
AN UNLABELED SPRAY BOTTLE WAS FOUND STORED IN THE CABINET UNDER THE SINK BY THE DISHWASH MACHINE. IT WAS THOUGHT THAT THIS SPRAY BOTTLE CONTAINED DEGREASER. THIS WAS DISCARDED IMMEDIATELY.
|
|
Recommendation:
7.6.1.1.2
Working containers used for storing poisonous or toxic materials such as cleaners and sanitizers taken from bulk supplies shall be clearly and individually identified with the common name of the material.
|
|
|
Item No.:
21
|
|
Site:
Other-GALLEY
|
|
Violation:
A SOFT, OPEN-CELLED GASKET WAS LOCATED ON THE EXTERIOR OF THE ICE MACHINE. THIS GASKET WAS RETAINING WATER. CORROSION WAS NOTED ON THE EXTERIOR OF THE ICE MACHINE.
|
|
Recommendation:
7.4.1.1.9
Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
01
|
|
Site:
Other-MEDICAL
|
|
Violation:
A GASTROINTESTINAL ILLNESS REPORT WAS NOT MADE TO THE VESSEL SANITATION PROGRAM BEFORE ARRIVING IN ALASKA FROM CANADA FOR THE CRUISE STARTING 5/28/03.
|
|
Recommendation:
4.2.1.1.1
The master, the medical staff, or other designated staff of a vessel destined for a U.S. port from a foreign port shall submit at least one standardized gastrointestinal illness report based on the number of reportable cases in the gastrointestinal illness log to the VSP no less than 24 hours, but not more than 30 hours before the vessel's expected arrival at the U.S. port.
4.2.1.2.1
The gastrointestinal illness report shall contain:
(1) The name of the vessel; (2) The ports of embarkation and disembarkation; (3) The dates of embarkation and disembarkation; (4) The total numbers of reportable cases of gastrointestinal illness among passengers and crew members, including those who have been disembarked or removed because of illness, even if the number is 0; and (5) The total number of passengers and crew members on the cruise.
|
|