Cruise Ship: Safari Quest Cruise Line: Un-Cruise Adventures Inspection Date: 06/28/2003 Inspection Score: 89
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 06
Site: Other-POTABLE WATER
Violation: THE HALOGEN ANALYZER-CHART RECORDER WAS NOT INSTALLED AT THE DISTANT POINT IN THE POTABLE WATER DISTRIBUTION SYSTEM. IT WAS INSTALLED IN THE ENGINE ROOM.
Recommendation: 5.5.1.1.1 A halogen analyzer-chart recorder shall be installed at a distant point in the potable water distribution system where a significant water flow exists.
Item No.: 06
Site: Other-POTABLE WATER
Violation: THE HALOGEN ANALYZER-CHART RECORDER CHARTS DID NOT HAVE A RANGE OF 0.0-5.0 PPM
Recommendation: 5.5.2.1.1 Halogen analyzer-chart recorder charts shall have a range of 0.0 to 5.0 mg/L (ppm) and have a recording period of 24 hours.
Item No.: 07
Site: Other-POTABLE WATER
Violation: A COPY OF THE VARIANCE FOR THE SKIN TANKS WAS NOT ABOARD THE VESSEL.
Recommendation: The ship should have a copy of the variance request for the skin tanks.
Item No.: 08
Site: Other-POTABLE WATER
Violation: A COMPREHENSIVE CROSS-CONNECTION CONTROL PROGRAM (PLAN) HAS NOT BEEN DEVELOPED FOR THIS VESSEL.
Recommendation: 5.7.1.1.3 The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE DECK TAP LOCATED UNDER THE STARBOARD GENERATOR DID NOT HAVE THE APPROPRIATE BACKFLOW PREVENTION DEVICE INSTALLED.
Recommendation: Install a continuous pressure backflow preventer.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE MAINTENANCE RECORDS INCLUDING CLEANING AND DISINFECTION WERE NOT AVAILABLE FOR THE POTABLE WATER TANKS.
Recommendation: 5.2.1.2.3 Accurate records of this monitoring shall be maintained aboard for 12 months and shall be available to the VSP for review during inspections.
Item No.: 06
Site: Other-POTABLE WATER
Violation: THE DISTRIBUTION SYSTEM WAS NOT PROVIDED WITH A BACK-UP HALOGEN PUMP WITH AN AUTOMATIC SWITCHOVER SHOULD THE PRIMARY PUMP FAIL.
Recommendation: 5.4.1.2.3 At least one backup halogen pump shall be available with automatic switchover to maintain the free residual halogen in the event that the primary pump fails.
Item No.: 06
Site: Other-POTABLE WATER
Violation: FOUR SAMPLES WERE NOT COLLECTED ON THE VESSEL EACH MONTH AND TESTED FOR THE PRESENCE OF E. COLI.
Recommendation: 5.6.1.1.1 A minimum of four potable water samples per month shall be collected and analyzed for the presence of Escherichia coli. Samples shall be collected randomly from locations forward, aft, upper, and lower decks of the vessel.
Item No.: 10
Site: Other-WHIRLPOOL SPA
Violation: THE RAISING OF THE CHLORINE RESIDUAL TO 10 PPM FOR 1 HOUR WAS NOT CONDUCTED AT THE END OF EACH DAY. THE WHIRLPOOL WAS BEING EMPTIED WEEKLY RATHER THAN DAILY AS REQUIRED. UNUSUALLY WATER EVENTS WERE NOT BEING DOCUMENTED.
Recommendation: 6.3.1.2.1 The whirlpool spa water shall be changed daily. 6.3.2.1.1 The free residual halogen shall be increased to at least 10.0 mg/L (ppm) in whirlpool spas and circulated for at least 1 hour at the end of each day. 6.2.2.2.6 Logs and charts shall contain notations of any unusual water events with the swimming pool operation and corrective actions taken.
Item No.: 33
Site: Other-FOOD SERVICE GENERAL
Violation: THE DECKS, BULKHEADS, AND DECKHEADS WERE DIFFICULT TO CLEAN DUE TO THEIR CONSTRUCTION.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 20
Site: Other-FOOD SERVICE GENERAL
Violation: THE FOOD CONTACT SURFACES OF EQUIPMENT WERE DIFFICULT TO CLEAN DUE TO GAPS, OPEN SEAMS, EXPOSED COILS AND OTHER FEATURES. DOMESTIC EQUIPMENT WAS NOTED AS FOLLOWS: BAR- DOMESTIC REFRIGERATOR GALLEY- DOMESTIC TOASTER, MIXER AND FOOD PROCESSOR.
Recommendation: 7.4.2.5.1 Food-contact surfaces of food equipment shall comply with American National Standards Institute (ANSI) or other internationally accredited food-equipment sanitation standards for materials, design, and construction. 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 38
Site: Other-GALLEY
Violation: AN ADEQUATE SPACE WAS NOT PROVIDED FOR STORING ITEMS SUCH AS A BROOM. A BROOM WAS STORED ON THE DECK BETWEEN THE FREEZER AND THE BULKHEAD.
Recommendation: 7.7.7.1.3 Maintenance tools such as mops, brooms, and similar items shall be stored in an orderly manner that facilitates cleaning of the area used for storing the maintenance tools. 7.7.7.1.4 After use, mops shall be placed in a position that allows them to air-dry without soiling walls, equipment, or supplies. 7.7.7.1.2 Maintenance tools such as mops, brooms, and similar items shall be stored in a designated locker so they do not contaminate food; food-contact surfaces of utensils; and equipment; linens, and single-service and single-use articles.
Item No.: 40
Site: Other-GALLEY
Violation: AN OPEN DOOR TO THE EXTERIOR WAS NOTED THAT WAS NOT PROVIDED WITH A SCREEN.
Recommendation: 8.2.1.1.2 Entry points where pests may enter the food areas shall be protected.
Item No.: 33
Site: Other-GALLEY
Violation: THE DECK WAS SOILED UNDER EQUIPMENT.
Recommendation: 7.7.4.2.1 Decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, shall be cleaned as often as necessary.
Item No.: 16
Site: Other-OUTSIDE REFRIGERATION UNIT
Violation: A PLASTIC BAG OF BLUE CHEESE WAS NOT MARKED WITH A USE BY DATE.
Recommendation: 7.3.5.3.3 Refrigerated, ready-to-eat, potentially hazardous food shall be discarded if not consumed within 7 calendar days from the date of preparation or opening.
Item No.: 31
Site: Other-GALLEY
Violation: THE SANITIZING SOLUTION BOTTLE FOR THE WAREWASH UNIT WAS NOT LABELED.
Recommendation: 7.6.1.1.2 Working containers used for storing poisonous or toxic materials such as cleaners and sanitizers taken from bulk supplies shall be clearly and individually identified with the common name of the material.
Item No.: 26
Site: Other-GALLEY
Violation: A FEW PREVIOUS CLEANED ITEMS WERE SOILED WITH A FOOD RESIDUE.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 26
Site: Other-GALLEY
Violation: THE OVENS WERE SLIGHTLY ENCRUSTED WITH A FOOD RESIDUE.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 20
Site: Other-GALLEY AND BAR
Violation: THE CUTTING BOARDS WERE PITTED AND SCORED.
Recommendation: 7.4.5.1.3 Surfaces such as cutting blocks and boards that are subject to scratching and scoring shall be resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
Item No.: 27
Site: Other-GALLEY
Violation: THE CABINETS IN THE GALLEY HAD SOME FOOD DEBRIS ON THE SHELVING.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 28
Site: Other-GALLEY
Violation: TONGS, LADLES AND SPATULAS WERE NOTED HANGING IN DIRECT CONTACT WITH THE BULKHEAD.
Recommendation: 7.5.7.3.1 Cleaned equipment and utensils, laundered linens, and single-service and single-use articles shall be stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
Item No.: 19
Site: Other-PROVISIONS
Violation: FOOD ITEMS WERE STORED DIRECTLY ON THE DECK.
Recommendation: 7.3.3.5.1 Food shall be protected from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
Item No.: 21
Site: Other-PROVISIONS
Violation: THE SHELVING WAS NOT CONSTRUCTED OF EASY TO CLEAN MATERIALS.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 33
Site: Other-PROVISIONS
Violation: A PORTION OF THE BULKHEAD WAS CONSTRUCTED OF PAINTED PARTICLE BOARD.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 36
Site: Other-PROVISIONS
Violation: ENSURE THE LIGHTING IS ADEQUATE FOR THE DRY STORES AREA.
Recommendation: 7.7.5.1.2 The light intensity shall be at least 110 Lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning.
Item No.: 19
Site: Other-PROVISIONS
Violation: BOXES OF SALT CRYSTALS WERE NOT ADEQUATELY PROTECTED FROM ITEMS FALLING FROM ABOVE.
Recommendation: 7.3.3.5.1 Food shall be protected from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
Item No.: 33
Site: Other-PROVISIONS
Violation: MOLD WAS NOTED ON THE BULKHEAD/DECKHEAD.
Recommendation: 7.7.4.2.1 Decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, shall be cleaned as often as necessary.
Item No.: 37
Site: Other-PROVISIONS
Violation: EXCESS MOISTURE WAS NOTED ON THE BULKHEADS.
Recommendation: 7.4.3.2.1 Ventilation hood systems and devices shall be sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
Item No.: 08
Site: Other-BAR
Violation: THE CARBONATOR WAS NOT FITTED WITH A VENTED BACKFLOW PREVENTION DEVICE.
Recommendation: Install a stainless steel vented backflow preventer on the carbonator. 7.4.1.1.5 Copper and copper alloys such as brass: (1) May not be used in contact with a food that has a pH below 6 such as vinegar, fruit juice, or wine or for a fitting or tubing installed between a backflow prevention device and a carbonator.
Item No.: 21
Site: Other-BAR
Violation: A THERMOMETER WAS NOT PROVIDED IN THE ABSOCOLD REFRIGERATOR.
Recommendation: 7.4.2.4.9.2 Temperature measuring devices shall conform to the following guidelines: (2) Cold or hot holding equipment used for potentially hazardous food shall be designed to include and shall be equipped with at least one integral or affixed temperature measuring device that is located to allow easy viewing of the device's temperature display.
Item No.: 33
Site: Other-BAR
Violation: THE DECK WAS SOILED AT THE JUNCTURE OF THE CABINETRY AND THE DECK.
Recommendation: 7.7.4.2.1 Decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, shall be cleaned as often as necessary.
Item No.: 20
Site: Other-BAR
Violation: THE CUTTING BOARD WAS BADLY WORN.
Recommendation: 7.4.5.1.3 Surfaces such as cutting blocks and boards that are subject to scratching and scoring shall be resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
Item No.: 40
Site: Other-INTEGRATED PEST MANAGEMENT PLAN
Violation: A COMPLETED INTEGRATED PEST MANAGEMENT PLAN HAS NOT BEEN DEVELOPED FOR THIS VESSEL.
Recommendation: 8.1.1.1.1 Each vessel shall develop an Integrated Pest Management Plan to address effective monitoring and control strategies for pests aboard the vessel. 8.1.1.1.2 The Integrated Pest Management Plan shall set a schedule for periodic monitoring inspections including some at night. 8.1.1.1.3 The Integrated Pest Management Plan shall include provisions for active monitoring including pest sighting logs for the operational areas of the vessel and training for crew members in charge of log completion. 8.1.1.1.4 The Integrated Pest Management Plan shall include passive surveillance procedures such as glue traps and other monitoring tools, as well as location of each. A monitoring log on passive surveillance procedures shall be maintained. 8.1.1.2.1 The vessel's Integrated Pest Management Plan shall be evaluated for effectiveness every 2 years or whenever there is a significant change in the vessel's structure such as a renovation or operation.
Item No.: 21
Site: Other-FOOD SERVICE GENERAL
Violation: THE NON-FOOD CONTACT SURFACES OF EQUIPMENT AND SHELVING WERE DIFFICULT TO CLEAN DUE TO OPEN SEAMS AND OTHER FEATURES.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 08
Site: Other-POTABLE WATER
Violation: SAMPLE VALVES WERE NOT INSTALLED ON THE POTABLE WATER TANKS.
Recommendation: 5.3.1.2.2 Potable water tanks shall have sample valves which are turned down.
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
Recommendation:
*Inspections scores of 85 or lower are NOT satisfactory