Cruise Ship: National Geographic Sea Lion Cruise Line: Lindblad Expeditions Inspection Date: 09/03/2003 Inspection Score: 90
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 08
Site: Other-BACKFLOW PREVENTION
Violation: THE WATER LINE INTO THE CARBONATOR WAS NOT PROTECTED FROM BACKFLOW/BACKSIPHONAGE.
Recommendation: Install the appropriate backflow preventer on this water line.
Item No.: 16
Site: Other-GALLEY REFRIGERATION
Violation: THE INTERNAL PRODUCT TEMPERATURE OF FOOD STORED IN THE REACH-IN REFRIGERATORS WAS MEASURED BETWEEN 47°F AND 67°F. THE RAW DUCK WAS 67°F (TWO SHEET PANS OF DUCK) AND WHOLE SHELL EGGS 47°F. THE POULTRY HAD BEEN PREPARED ONE HOUR PRIOR FOR SERVICE APPROXIMATELY FOUR HOURS LATER. THE INTERNAL PRODUCT TEMPERATURE OF FOOD STORED IN THE REACH-IN OF THE DRY STORE REFRIGERATION UNIT WAS BETWEEN 47°F AND 50°F. A COOKED TURKEY BREAST WAS 50°F. CREW STATED THAT THE TURKEY HAD BEEN PREPARED MORE THAN TWENTY-FOUR HOURS PRIOR. THE INTERNAL PRODUCT TEMPERATURE OF THE CUT MELON AND YOGURT WAS 47°F. THE FOOD OUT OF TEMPERATURE WAS DISCARDED DURING THE INSPECTION.
Recommendation: 7.3.5.2.1 Cooked potentially hazardous food shall be cooled: (1) Within 2 hours, from 60°C (140°F) to 21°C (70°F); and (2) Within 4 hours, from 21°C (70°F) to 5°C (41°F) or less. 7.3.5.3.1.1 Potentially hazardous food shall be maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above,; or (2) At 5°C (41°F) or less.
Item No.: 26
Site: Other-GALLEY
Violation: THE MIXER COLLAR AND THE FOOD SPLASH ZONE AREA ABOVE THE MIXING BOWL WERE SOILED WITH DRIED FOOD DEBRIS.
Recommendation: 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 26
Site: Other-GALLEY & DINNING ROOM
Violation: NUMEROUS PREVIOUSLY CLEANED DISHES, GLASSES, SILVERWARE AND COOKWARE, STORED AS CLEAN, WERE FOUND SOILED WITH DRIED FOOD DEBRIS. SEVERAL UTENSILS IN THE DRAWERS WERE ALSO FOUND SOILED WITH FOOD SPLASH.
Recommendation: 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 20
Site: Other-GALLEY REFRIGERATION UNITS
Violation: THE THERMOMETERS LOCATED INSIDE THE REFRIGERATION UNITS INDICATED TEMPERATURES OF 65°F IN THE GALLEY REACH-IN AND 47°F IN THE REACH-IN LOCATED IN THE DRY STORE ROOM. TEMPERATURE LOGS SHOWED THE CORRECT TEMPERATURES TAKEN FROM THE EXTERIOR THERMOMETERS DURING THE PREVIOUS EVENING/EARLY MORNING HOURS. STAFF STATED THAT THE REFRIGERATION UNITS WERE IN THE DEFROST MODE AND HAD BEEN OPENED EXTENSIVELY DURING THE LUNCH PREPARATION TIME. POTENTIALLY HAZARDOUS FOODS WERE NOTED TO BE IN THE TEMPERATURE DANGER ZONE IN THESE UNITS.
Recommendation: 7.4.3.1.1 Equipment for cooling and heating food, and holding cold and hot food, shall be sufficient in number and capacity to maintain specified potentially hazardous food temperatures.
Item No.: 20
Site: Other-GALLEY
Violation: SEVERAL CUTTING BOARDS WERE DEEPLY GOUGED, MAKING THEM DIFFICULT TO CLEAN.
Recommendation: 7.4.5.1.3 Surfaces such as cutting blocks and boards that are subject to scratching and scoring shall be resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
Item No.: 27
Site: Other-GALLEY
Violation: THE CARDBOARD ALUMINUM AND PLASTIC WRAP DISPENSERS WERE FOUND SOILED WITH FOOD DEBRIS.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Other-GALLEY
Violation: THE ALUMINUM AND PLASTIC WRAP DISPENSERS WERE MADE OF CARDBOARD AND WERE NOT EASY TO CLEAN.
Recommendation: 7.4.1.1.2 Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
Item No.: 38
Site: Other-GALLEY
Violation: A STEREO WAS ON THE GALLEY COUNTER MAKING THE AREA DIFFICULT TO CLEAN. COMPACT DISKS WERE STORED IN THE CUPBOARD WITH FOOD SERVICE EQUIPMENT.
Recommendation: 7.7.7.1.1 Only articles necessary for the food service operation shall be stored in food preparation, food storage, and warewashing areas.
Item No.: 26
Site: Other-GALLEY
Violation: THE TOP INTERIOR OF THE MICROWAVE WAS SOILED WITH OLD FOOD DEBRIS.
Recommendation: 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 26
Site: Other-BAR
Violation: THE BLENDER BLADE AND GASKET WERE SOILED WITH DRINK RESIDUE.
Recommendation: 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 08
Site: Other-BAR
Violation: A VENTED BACKFLOW PREVENTION DEVICE WAS NOT PROVIDED ON THE CARBONATOR.
Recommendation: 7.4.1.1.5 Copper and copper alloys such as brass: (1) May not be used in contact with a food that has a pH below 6 such as vinegar, fruit juice, or wine or for a fitting or tubing installed between a backflow prevention device and a carbonator.
Item No.: 08
Site: Other-BACKFLOW PREVENTION
Violation: THE VESSEL DOES NOT HAVE A COMPREHENSIVE CROSS-CONNECTION CONTROL PLAN.
Recommendation: 5.7.1.1.3 The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
Item No.: 26
Site: Other-GALLEY HALL
Violation: THE ICE MACHINE CUBER AREAS/HOSES AND WATER TRAY WERE HEAVILY SOILED WITH BLACK MOLD.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 07
Site: Other-GALLEY HALL
Violation: THE ICE MACHINE DRAIN LINE APPEARED TO BE DIRECTLY PLUMBED TO THE GRAY WATER SYSTEM.
Recommendation: 7.7.3.1.1 Drain lines from all fixtures, sinks, appliances, compartments, refrigeration units, or devices that are used, designed for, or intended to be used in the preparation, processing, storage, or handling of food, ice, or drinks shall be indirectly connected to appropriate waste systems by means of an air-gap or air-break.
Item No.: 33
Site: Other-ICE MACHINE AREA
Violation: THE DECK BENEATH THE ICE MACHINE WAS HEAVILY SOILED WITH DIRT AND DEBRIS.
Recommendation: 7.7.4.2.1 Decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, shall be cleaned as often as necessary.
Item No.: 18
Site: Other-GALLEY
Violation: RAW BEEF WAS STORED ABOVE COOKED RICE IN THE REFRIGERATOR. RAW FISH WAS STORED BELOW RAW POULTRY IN THE REFRIGERATOR. THIS SEQUENCE OF STORAGE CAN SUBJECT THE COOKED RICE TO CROSS-CONTAMINATION FROM THE BEEF JUICES AND CAN SUBJECT THE RAW FISH TO CROSS-CONTAMINATION FROM THE JUICES OF THE POULTRY.
Recommendation: 7.3.3.2.1.1 Food shall be protected from cross-contamination by: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food including other raw animal food such as fish for sushi or molluscan shellfish, or other raw ready-to-eat food such as vegetables, and cooked ready-to-eat food; so products do not physically touch, and so as to prevent dripping of one product into another. 7.3.3.2.1.1 Food shall be protected from cross-contamination by: (2) Except when combined as ingredients, separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry during storage, preparation, holding, and display by using separate equipment for each type, or arranging each type of food in equipment so that cross-contamination of one type with another is prevented, and preparing each type of food at different times or in separate areas.
Item No.: 06
Site: Other-POTABLE WATER DISTRIBUTION
Violation: A BACKUP HALOGENATION PUMP WITH AN AUTOMATIC SWITCHOVER WAS NOT PROVIDED FOR THE DISTRIBUTION SYSTEM.
Recommendation: 5.4.1.2.3 At least one backup halogen pump shall be available with automatic switchover to maintain the free residual halogen in the event that the primary pump fails.
Item No.: 08
Site: Other-BACKFLOW PREVENTION
Violation: NUMEROUS WASH DOWN HOSES WITH PRESSURE FITTINGS WERE NOT PROTECTED FROM BACKFLOW/BACKSIPHONAGE.
Recommendation: Install the appropriate backflow preventers on these lines.
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
Recommendation:
*Inspections scores of 85 or lower are NOT satisfactory