Item No.:
20
|
|
Site:
Other-GALLEY
|
|
Violation:
THE HAND HELD MIXER WAS NOT EASY TO CLEAN DUE TO SLOTTED SCREWS AND THE BLADE ATTACHMENT BOLTS.
|
|
Recommendation:
7.4.1.1.2
Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be:
(1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
|
|
|
Item No.:
26
|
|
Site:
Other-GALLEY
|
|
Violation:
THE HAND HELD MIXER BLADE AREA WAS SOILED WITH DRIED FOOD DEBRIS.
|
|
Recommendation:
7.3.3.4.1
Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
|
|
|
Item No.:
19
|
|
Site:
Other-FOOD SERVICE GENERAL-CONDENSATION
|
|
Violation:
CONDENSATION WAS DRIPPING ONTO THE DECK AND HAD ACCUMULATED ON THE BULKHEAD IN THE DRY STORE AREA. CONDENSATION WAS NOTED ALONG THE TOP OF THE BULKHEAD IN THE WALK-IN REFRIGERATION UNIT. CONDENSATION WAS NOTED ON THE DECKHEAD, BULKHEAD, DECK AND ON THE TOP AND SIDES OF CARDBOARD BOXES OF FOOD IN THE MEAT FREEZER.
|
|
Recommendation:
7.3.3.5.2
Food may not be stored:
(1) In locker rooms; (2) In toilet rooms; (3) In dressing rooms; (4) In garbage rooms; (5) In mechanical rooms; (6) Under sewer lines that are not continuously sleeve welded; (7) Under leaking water lines, including leaking automatic fire sprinkler heads, or under lines on which water has condensed; (8) Under open stairwells; or (9) Under other sources of contamination from nonfood items such as ice blocks, ice carvings and flowers.
7.3.3.5.1
Food shall be protected from contamination by storing the food:
(1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
20
|
|
Site:
Other-CREW GALLEY-COLD PANTRY
|
|
Violation:
A GAP WAS NOTED ON THE BACK PLATE OF THE MEAT SLICER ALLOWING FOOD TO ACCUMULATE. THE SLICER GUARDS WERE CLEAN AT THE TIME OF THE INSPECTION.
|
|
Recommendation:
7.4.2.2.1
Multiuse food-contact surfaces shall be:
(1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
|
|
|
Item No.:
19
|
|
Site:
Other-PASTRY & CREW GALLEY
|
|
Violation:
MILK WAS BEING DISPENSED FROM BULK PLASTIC BAGS WITH THE DISPENSING HOSE TIED INTO A KNOT UNTIL USED AGAIN. THE PRODUCT WAS STORED IN A PLASTIC LABELED BIN IN THE WALK-IN REFRIGERATION UNITS.
|
|
Recommendation:
Bulk dispensing bags are designed to be used in a dispenser. Recommend that a dispenser be used or milk be purchased in more appropite containers.
|
|
|
Item No.:
08
|
|
Site:
Other-FOOD SERVICE GENERAL
|
|
Violation:
AN AIR GAP WAS NOT MAINTAINED AT THE POTABLE WATER OUTLET OF THE ICE CREAM DIPPER WELLS.
|
|
Recommendation:
5.7.1.2.2
Air gaps shall be at least twice the diameter of the delivery fixture opening and a minimum of 3 cm (1 inch).
|
|
|
Item No.:
18
|
|
Site:
Other-PROVISIONS-POULTRY FREEZER
|
|
Violation:
BOXES OF FROZEN UNCOOKED POULTRY WERE STORED NEXT TO BOXES OF FROZEN COOKED READY TO EAT FOODS.
|
|
Recommendation:
7.3.3.2.1.1
Food shall be protected from cross-contamination by: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food including other raw animal food such as fish for sushi or molluscan shellfish, or other raw ready-to-eat food such as vegetables, and cooked ready-to-eat food; so products do not physically touch, and so as to prevent dripping of one product into another.
|
|
|
Item No.:
20
|
|
Site:
Other-BAKERY
|
|
Violation:
THE DOUGH ROLLER BELT WAS WORN AND NO LONGER EASY TO CLEAN DUE TO CUTS IN THE BELT. STAFF STATED THAT A NEW BELT HAS BEEN ORDERED AND WILL BE INSTALLED WITHIN THE NEXT MONTH.
|
|
Recommendation:
7.4.2.2.1
Multiuse food-contact surfaces shall be:
(1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
|
|
|
Item No.:
34
|
|
Site:
Other-CREW GALLEY
|
|
Violation:
THE HOT LINE BAIN MARIE FAUCET LEAKED.
|
|
Recommendation:
7.7.3.3.1
A plumbing system in a food area shall be maintained in good repair.
|
|
|
Item No.:
22
|
|
Site:
Other-DISHWASH-CREW GALLEY
|
|
Violation:
ALL THE GAUGES ON THE DISHWASH MACHINE READ 140 °F. THE TEMERATURE OF THE FINAL RINSE WAS RECORDED WITH A MAXIMUM REGISTERING THERMOMTER AT 149 °F. THE PRESSURE GAUGE IS ONLY TURNED ON WHEN IT IS BEING CHECKED.
|
|
Recommendation:
7.5.2.1.1
Water temperature measuring devices:
(1) That are scaled in Celsius or dually scaled in Celsius and Fahrenheit shall be designed to be accurate to ±1.5°C in the intended range of use. (2) That are scaled only in Fahrenheit shall designed to be accurate to ±3°F in the intended range of use.
7.5.4.1.1
Warewashing equipment shall be maintained in good repair and proper adjustment including:
(1) Warewashing equipment shall be maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines. (2) Water pressure, and water temperature measuring devices shall be maintained in good repair and be accurate within the intended range of use.
7.5.2.2.7
Warewashing machines that provide a fresh hot water sanitizing rinse:
(1) Shall be equipped with a pressure gauge or similar device such as a transducer that measures and displays the water pressure in the supply line immediately before entering the warewashing machine; and (2) If the flow pressure measuring device is upstream of the fresh hot water sanitizing rinse control valve, the device shall be mounted in a 6.4 mm (1/4 inch) Iron Pipe Size (IPS) valve.
|
|
|
Item No.:
22
|
|
Site:
Other-DISHWASH-MAIN GALLEY
|
|
Violation:
THE FINAL RINSE TEMPERATURE GAUGE DISPLAYED A TEMPERATURE OF 215 ° F DURING THE FINAL RINSE CYCLE, WHEREAS THE MAXIMUM REGISTERING THERMOMETER TEMERATURE WAS 149 °. THE GAUGE WAS OUT OF CALIBRATION BY 66 ° F.
|
|
Recommendation:
7.5.2.1.1
Water temperature measuring devices:
(1) That are scaled in Celsius or dually scaled in Celsius and Fahrenheit shall be designed to be accurate to ±1.5°C in the intended range of use. (2) That are scaled only in Fahrenheit shall designed to be accurate to ±3°F in the intended range of use.
|
|
|
Item No.:
24
|
|
Site:
Other-DISHWASH CREW AND MAIN GALLEY
|
|
Violation:
THE CREW AND MAIN GALLEY DISHWASH FINAL RINSE CYCLE TEMPERATURES WERE RECORDED SEVERAL TIMES ON THE MAXIMUM REGISTERING THERMOMETER AT 149 ° F. BOTH MACHINES WERE IN ACTIVE USE AT THE TIME. THESE UNITS WERE REPAIRED DURING THE INSPECTION.
|
|
Recommendation:
7.5.6.1.2
In a mechanical operation, the temperature of the fresh hot water sanitizing rinse as it enters the manifold may not be more than 90°C (194°F), or less than:
(1) For a stationary rack, single temperature machine, 74°C (165°F); or (2) For all other machines, 82°C (180°F). (3) A utensil surface temperature of 71°C (160°F) as measured by an irreversible registering temperature indicator shall be achieved. (4) The maximum temperature of 90°C (194°F), does not apply to the high pressure and temperature systems with wand-type, hand-held, spraying devices used for the in-place cleaning and sanitizing of equipment such as meat saws.
|
|
|
Item No.:
21
|
|
Site:
Other-LIDO PANTRY
|
|
Violation:
PEELING SEALANT WAS NOTED ON THE SEAM BETWEEN THE FLAT TOP GRILLS IN THE HOT PREPARATION AREA.
|
|
Recommendation:
7.4.2.2.6
Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
33
|
|
Site:
Other-LIDO PANTRY
|
|
Violation:
A GAP WAS NOTED BETWEEN THE BULKHEAD PANELS NEXT TO THE FLAT TOP GRILL IN THE HOT PREPARATION AREA.
|
|
Recommendation:
7.7.4.1.1
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Other-LIDO PANTRY
|
|
Violation:
A HOLE WAS NOTED IN THE BULKHEAD BEHIND THE COMBI-OVEN IN THE HOT PREPARATION AREA.
|
|
Recommendation:
7.7.4.1.1
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Other-TRIDENT GRILL
|
|
Violation:
PEELING SEALANT WAS NOTED AT THE BULKHEAD/DECK JUNCTURE IN THE OVEN AREA.
|
|
Recommendation:
7.7.4.1.8
Surfaces subject to routine splashes, spillage or other soiling during normal use shall have easily cleanable features.
7.7.4.2.3
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair.
|
|
|
Item No.:
08
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
ON SEVERAL DAYS PRIOR TO BUNKERING THE SHORE SIDE HALOGEN LEVEL AND PH WAS NOT RECORDED.
|
|
Recommendation:
5.2.1.2.1
A halogen demand test and pH shall be conducted on the shore-side water supply before starting the bunkering process to establish the correct halogen dosage.
|
|
|
Item No.:
30
|
|
Site:
Other-CRYSTAL COVE BAR
|
|
Violation:
THE SOAP DISPENSER AT THE HANDWASH SINK WAS NOT WORKING PROPERLY.
|
|
Recommendation:
7.7.1.3.2
Handwashing facilities shall be kept clean and in good repair.
|
|
|
Item No.:
01
|
|
Site:
Other-MEDICAL
|
|
Violation:
ON SEPTEMBER 21, 2003 AT 6:02 AM, THE SHIP ATTEMPTED TO SEND A GASTROINTESTINAL ILLNESS REPORT TO THE VSP SYSTEM FOR A SEPTEMBER 22 ARRIVAL IN BAR HARBOR FROM CANADA. THE SHIP RECEIVED A EMAIL FROM THE VSP SYSTEM STATING THAT THE REPORT HAD NOT BEEN PROCESSED DUE TO THE INCORRECT TEMPLATE BEING USED. THE EMAIL FROM THE VSP GAVE EXPLICIT INSTRUCTIONS ON HOW TO OBTAIN THE CORRECT TEMPLATE AND THE SPECIFIC PROBLEMS WITH THE REPORT THAT WAS SENT. NO FURTHER ATTEMPTS AT REPORTING WERE MADE EITHER BY EMAIL, FAX, OR PHONE.
|
|
Recommendation:
4.2.1.1.1
The master, the medical staff, or other designated staff of a vessel destined for a U.S. port from a foreign port shall submit at least one standardized gastrointestinal illness report based on the number of reportable cases in the gastrointestinal illness log to the VSP no less than 24 hours, but not more than 30 hours before the vessel's expected arrival at the U.S. port.
|
|
|
Item No.:
36
|
|
Site:
Other-CRYSTAL COVE BAR
|
|
Violation:
THE LIGHTS WERE NOT SHATTER RESISTANT OR SHIELDED OVER THE SEATING AREA OF THE BAR.
|
|
Recommendation:
7.7.5.2.1
Light bulbs shall be shielded, coated, or otherwise shatter-resistant in areas where there is exposed food; clean equipment, utensils, and linens; or unwrapped single-service, and single-use articles.
|
|
|
Item No.:
*
|
|
Site:
Other-CORRECTIVE ACTION STATEMENT
|
|
Violation:
IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY.
PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV
USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME-CRYSTAL SYMPHONY - CAS - [INSERT INSPECTION DATE-09-23-2003].
|
|
Recommendation:
|
|