Cruise Ship: Seaventure Cruise Line: Polar Latitudes Inspection Date: 09/02/2003 Inspection Score: 95
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 22
Site: Other-FOOD SERVICE - GENERAL
Violation: THE DATA PLATES FOR THE DISHWASHING AND GLASSWASHING MACHINES DID NOT HAVE INCLUDE THE MINIMUM WASH, RINSE, AND SANITIZE RINSE CYCLE TIMES.
Recommendation: 7.5.2.2.3 A warewashing machine shall be provided with an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operating specifications including the: (1) Temperatures required for washing, rinsing, and sanitizing; (2) Pressure required for the fresh water sanitizing rinse; and (3) Conveyor speed for conveyor machines or cycle time for stationary rack machines.
Item No.: 16
Site: Other-FOOD SERVICE - GENERAL
Violation: TIME AS A PUBLIC HEALTH CONTROL WAS BEING USED ONBOARD THE VESSEL BUT THERE WAS NO WRITTEN TIME CONTROL PLAN. LOGS WERE MAINTAINED AND AVAILABLE AND THE MEAL SERVICE TIMES WERE LESS THAN FOUR HOURS IN LENGTH.
Recommendation: Develop a written time control plan that includes length of meal service, temperatures that hot foods and cold foods are stored, and disposition of foods that are on time control. Ensure that if there are potentially hazardous food such as individual yogurts that are not considered on time control that the plan specifies they are not on time control.
Item No.: 40
Site: Other-FOOD SERVICE - GENERAL
Violation: THE INSECT LIGHTS WERE LOCATED OVER FOOD PREPARATION COUNTERS AND/OR CLEAN DISH STORAGE AREAS.
Recommendation: Relocate the insect lights so they are not over food preparation areas and/or clean dish storage areas.
Item No.: 29
Site: Other-CLUB BAR
Violation: THE HANDWASHING STATION FOR THE BAR IS LOCATED IN THE PANTRY. IT WAS NOT CLEAR WHETHER THE DOOR WAS NORMALLY OPEN DURING BAR OPERATIONS.
Recommendation: Provide access to the handwashing station from the bar without having to pass through a normally closed door.
Item No.: 05
Site: Other-POTABLE WATER
Violation: THE FAR POINT ANALYZER WAS OUT OF CALIBRATION. THE ANALYZER READ 3.34 PPM AND THE MANUAL TEST WAS 1.98. THE CHART INDICATED THAT THE ANALYZER WAS CALIBRATED EARLIER IN THE DAY AND THE ENGINEER STATED THAT THE PROBE AND ELECTROLYTE WAS CHANGED LESS THAN ONE MONTH EARLIER AND HE HAS BEEN HAVING DIFFICULTY MAINTAINING THE CALIBRATION.
Recommendation: 5.5.1.2.3 The free residual halogen measured by the halogen analyzer shall be ±0.2 mg/L (ppm) of the free residual halogen measured by the manual test.
Item No.: *
Site: Other-RECOMMENDED CORRECTIVE ACTION
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: BREMEN - CAS - 9/02/2003 .
Recommendation:
*Inspections scores of 85 or lower are NOT satisfactory