Cruise Ship: Silver Whisper Cruise Line: Silversea Inspection Date: 10/09/2003 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 38
Site: Other-FOOD SERVICE GENERAL
Violation: A COUPLE OF PIECES OF EQUIPMENT (TAYLOR SORBET MACHINE, POTATO PEELER) WERE POSTED OUT OF ORDER. THE SHIP WILL DECIDE THE DISPOSITION OF THE EQUIPMENT AND EITHER HAVE THEM REPAIRED OR DISPOSE OF THEM PROPERLY.
Recommendation: Determine equipment needs and either repair or remove equipment that is posted out of order.
Item No.: 30
Site: Other-MAIN GALLEY - POTWASH AREA
Violation: THE "WASH HANDS OFTEN SIGN" WAS NOT POSTED AT THE HANDWASH SINK OUTSIDE THE POTWASH AREA. THIS ITEM WAS CORRECTED DURING THE INSPECTION.
Recommendation: 7.7.1.1.7 A sign stating "WASH HANDS OFTEN" in a language that the food employees understand shall be posted over handwashing sinks.
Item No.: 26
Site: Other-MAIN GALLEY - COLD GALLEY
Violation: A PREVIOUSLY CLEANED BUFFALO CHOPPER BOWL WAS FOUND SOILED WITH A GREASY RESIDUE.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 33
Site: Other-MAIN GALLEY - PASTRY AREA
Violation: A PROFILE STRIP WAS SEPARATING FROM THE BULKHEAD/DECKHEAD JUNCTURE INSIDE THE WALK-IN REFRIGERATOR ENTRY.
Recommendation: 7.7.4.2.3 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair.
Item No.: 33
Site: Other-TERRACE CAFÉ
Violation: A PROFILE STRIP WAS SEPARATING FROM THE BULKHEAD AT THE INSIDE OF THE WALK-IN REFRIGERATOR.
Recommendation: 7.7.4.2.3 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair.
Item No.: 22
Site: Other-MAIN GALLEY - POTWASH AREA
Violation: THE POTWASH WAS POSTED OUT OF ORDER. A REQUISITION FOR REPAIR WAS ON FILE AND ENGINEERING PERSONNEL ANTICIPATES THAT REPAIRS WILL BE MADE WITHIN TWO WEEKS. THERE ARE ADEQUATE BACKUP POTWASH ASSETS ON BOARD THE VESSEL.
Recommendation: Repair potwash and place bck into service as soon as spare parts are received on board the vessel.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE BUNKER STATIONS EACH HAD FIVE HOSE CONNECTIONS FOR THE INTERNATIONAL SHORE CONNECTION FOR THE FIRE SUPPRESSION SYSTEM. ONLY TWO OUT OF EACH OF THE FIVE CONNECTIONS HAD REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTION DEVICES INSTALLED.
Recommendation: Install reduced pressure principle backflow preventers on all international shore connections.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE COMPREHENSIVE CROSS CONNECTION CONTROL PROGRAM DID NOT ADDRESS ALL OF THE CONNECTIONS TO THE POTABLE WATER SYSTEM. THE AIR GAP AT THE PORT WHIRLPOOL SPA MAKE-UP TANKS WAS CIRCUMVENTED.
Recommendation: 5.7.1.1.3 The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE SAMPLE POINTS FOR THE POTABLE WATER TANKS DID NOT POINT DOWN.
Recommendation: 5.3.1.2.2 Potable water tanks shall have sample valves which are turned down.
Item No.: *
Site: Other-POTABLE WATER
Violation: THE RECORDS FOR THE POTABLE WATER SYSTEM WERE EXCELLENT.
Recommendation:
Item No.: 10
Site: Other-WHIRLPOOL SPAS
Violation: THE FILTERS FOR THE WHIRLPOOLS SPAS WERE NOT OPENED MONTHLY AND CHECKED FOR CRACKS AND MOUNDS IN THE FILTER MEDIA. A MONTHLY SEDIMENTATION TEST WAS NOT PERFORMED ON THE FILTER MEDIA TO CHECK FOR EXCESSIVE ORGANIC MATERIAL ACCUMULATION.
Recommendation: 6.3.1.1.3 Cartridge or cannister-type filters shall be inspected at least weekly for cracks, breaks, damaged components, and excessive organic material accumulation.
Item No.: 25
Site: Other-DECK 6 ROOM SERVICE PANTRY
Violation: A WET WIPING CLOTH WAS DRAPED ON THE SIDE OF THE SANTIZE BUCKET.
Recommendation: 7.3.3.4.4.3 Wiping cloths shall be restricted to the following: (3) Dry or wet cloths that are used with raw animal foods shall be kept separate from cloths used for other purposes, and wet cloths used with raw animal foods shall be kept in a separate sanitizing solution.
Item No.: 26
Site: Other-POOL GRILL
Violation: THE FRYER COILS WERE SOILED.
Recommendation: 7.5.5.1.2 The food-contact surfaces of cooking equipment and pans shall be kept free of encrusted grease deposits and other soil accumulations.
Item No.: 25
Site: Other-PANORAMA BAR
Violation: A WET WIPING CLOTH WAS DRAPED ON THE SIDE OF THE SANITIZE BUCKET.
Recommendation: 7.3.3.4.4.3 Wiping cloths shall be restricted to the following: (3) Dry or wet cloths that are used with raw animal foods shall be kept separate from cloths used for other purposes, and wet cloths used with raw animal foods shall be kept in a separate sanitizing solution.
Item No.: 21
Site: Other-PANORAMA BAR
Violation: MOLD STAIN WAS NOTED ON THE SOFT SEALANT USED IN THE TECHNICAL COMPARTMENTS UNDER THE SINKS.
Recommendation: Clean or replace mold-stained sealant.
Item No.: 41
Site: Other-VENTILATION
Violation: THE CONDENSATE COLLECTION DRAIN PANS INSIDE THE AIR CONDITIONING UNITS WERE NOT ACCESSIBLE FOR INSPECTION. THIS WAS NOTED DURING THE LAST INSPECTION. THE VESSEL IS SCHEDULED TO BEGIN AND COMPLETE THE INSTALLATION OF VIEWING PORTS IN THE NOVEMBER, 2003 DRYDOCK.
Recommendation: Install inspection and cleaning port(s) during November, 2003 drydock period.
Item No.: *
Site: Other-MEDICAL
Violation: THE VESSEL WAS FAXING IN THE 24-HOUR PRIOR TO ARRIVAL REPORTS.
Recommendation: Prefer the submssion of reports via the VSP-Reports e-mail system as reports are entered directly into the database. A report template can be obtained by sending an e-mail to VSP-Reports with the keyword "template" in the subject line. Utilize faxing method as a back-up in the event the e-mail system is inoperative.
Item No.: *
Site: Other-
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SILVER WHISPER - CAS - 10/09/2003 .
Recommendation:
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program