Cruise Ship: Wind Surf Cruise Line: Windstar Cruises Inspection Date: 04/06/2003 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 20
Site: Other-DECK 3 PREPARATION GALLEY
Violation: A GAP WAS NOTED ON THE FOOD CONTACT AREA OF THE MEAT SLICER. CORRECTED DURING INSPECTION.
Recommendation: Ensure that multiuse food-contact surfaces are smooth and free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections.
Item No.: 20
Site: Other-DECK 3 PREPARATION GALLEY
Violation: SLIGHT CORROSION WAS NOTED IN THE BIN OF THE ICE MAKER.
Recommendation: Ensure that materials used in the construction of multiuse utensils and food-contact surfaces of equipment are durable, corrosion-resistant, and nonabsorbent.
Item No.: 21
Site: Other-DECK 3 PREPARATION GALLEY
Violation: CORROSION WAS NOTED IN THE COLLAR AND ON THE HOUSING AREA OF THE FLOOR MOUNTED HOBART MIXER.
Recommendation: Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 27
Site: Other-DECK 3 PREPARATION GALLEY
Violation: THE COLLAR AND HOUSING AREA OF THE FLOOR MOUNTED HOBART MIXER WAS SOILED.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 26
Site: Other-DECK 3 PREPARATION GALLEY
Violation: SLIGHT MOLD AND MILDEW WAS NOTED IN THE ICE MAKING AREA OF THE KOLD-DRAFT ICE MACHINE. CORRECTED DURING INSPECTION.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 19
Site: Other-BISTRO GALLEY
Violation: A CONTAINER OF COOKING OIL WAS NOT LABELED.
Recommendation: Ensure that working containers holding food or food ingredients that are removed from their original packages for use on the vessel, such as cooking oils, flour, herbs, potato flakes, salt, spices, and sugar are identified with the common name of the food.
Item No.: 26
Site: Other-BISTRO GALLEY
Violation: CARBONIZED FOOD RESIDUE WAS NOTED ON THE FRYER COILS.
Recommendation: Ensure that the food-contact surfaces of cooking equipment and pans are kept free of encrusted grease deposits and other soil accumulations.
Item No.: 27
Site: Other-COMPASS BAR
Violation: THE TECHNICAL AREA UNDER REFRIGERATION UNIT 34 WAS SOILED. CORRECTED DURING INSPECTION.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: *
Site: Other-COMMENT
Violation: THE RECORD KEEPING AND MANAGEMENT OF THE POTABLE WATER, POOLS, WHIRLPOOLS, HOUSEKEEPING, AND PEST CONTROL WAS EXCELLENT.
Recommendation:
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: WIND SURF - CAS - 4/6/03.
Recommendation:
*Inspections scores of 85 or lower are NOT satisfactory