Cruise Ship: Seven Seas Navigator Cruise Line: Regent Seven Seas Inspection Date: 02/26/2003 Inspection Score: 99
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 21
Site: Other-FOOD SERVICE GENERAL
Violation: THE VENTILATION HOODS HAD LOOSE SEALANT THAT WAS MISSING AND PEELING THEREFORE EXPOSING OPEN SEAMS MAKING CLEANING DIFFICULT.
Recommendation: 7.4.2.1.2 Nonfood-contact surfaces of equipment and utensils shall be designed and constructed to be durable and to retain their characteristic qualities under normal use conditions.
Item No.: 37
Site: Other-MAIN GALLEY
Violation: HEAVY CONDENSATION WAS NOTED ON THE DECKHEAD ABOVE THE STEAM KETTLE COOKING STATION.
Recommendation: 7.7.6.1.1 All food preparation, warewashing, and toilet rooms shall have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes.
Item No.: 37
Site: Other-MAIN GALLEY
Violation: HEAVY CONDENSATION WAS NOTED ON THE DECKHEAD AT THE DIRTY END OF THE WAREWASHER.
Recommendation: 7.7.6.1.1 All food preparation, warewashing, and toilet rooms shall have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes.
Item No.: 26
Site: Other-MAIN GALLEY
Violation: THE FRESH ORANGE JUICE JUICER WAS HEAVILY SOILED WITH DRIED PULP AND JUICE.
Recommendation: 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 37
Site: Other-CREW GALLEY
Violation: HEAVY CONDENSATION WAS NOTED ON THE DECKHEAD ABOVE THE STEAM KETTLE COOKING STATION.
Recommendation: 7.7.6.1.1 All food preparation, warewashing, and toilet rooms shall have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes.
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
Recommendation:
Item No.: 28
Site: Other-PORTOFINO - CENTER WAIT STATION
Violation: THREE COFFEE CARAFES WERE NOT STORED INVERTED TO ALLOW THE WATER TO DRAIN FROM THEM.
Recommendation: 7.5.7.3.2 Clean equipment and utensils shall be stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
Item No.: 21
Site: Other-PORTOFINO - WAIT STATIONS
Violation: THE FORMICA WAS DAMAGED IN SOME AREAS OF THE WAITER STATIONS.
Recommendation: 7.4.2.2.6 Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 08
Site: Other-PORTABLE WATER
Violation: THE PRESSURE DIFFERENCE NEEDS TO BE RECORDED WHEN TESTING THE TESTABLE REDUCED PRESSURE BACKFLOW ASSEMBLIES.
Recommendation: 5.7.2.2.2 Backflow prevention devices requiring testing, for example reduced pressure backflow preventer and double check valves with test cocks, shall be inspected and tested with a test kit at least annually. Test results showing the pressure differences on both sides of the valves shall be maintained for each device.
Item No.: 08
Site: Other-POTABLE WATER
Violation: ENSURE THAT THE DECK TAPS THAT ARE USED TO ATTACH HOSES TO WASH THE DECK HAVE THE APPROPRIATE BACKFLOW DEVICE INSTALLED ON THEM.
Recommendation: 5.7.1.1.3 The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.