Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Seven Seas Navigator Cruise Line: Regent Seven Seas Inspection Date: 09/03/2003 Inspection Score: 94
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 29
Site: Other-MAIN GALLEY DISHWASH
Violation: THE WATER TEMPERATURE AT THE TRIPLE HANDWASH STATION WAS TESTED FROM 120-128°F. THIS TEMPERATURE WAS TOO HOT TO ADEQUATELY WASH HANDS.
Recommendation: Ensure that the water temperature is set to a temperature that is suitable for handwashing. Ideally an individual should be able to adjust the water temperature to suit their comfort level. 7.7.1.1.3 A handwashing sink shall be equipped to provide water at a temperature of at least 43°C (110°F) through a mixing valve or combination faucet.
Item No.: 31
Site: Other-MAIN GALLEY-SILVER ROOM
Violation: THINNER WAS STORED IN A SMALL WATER BOTTLE. THE WATER BOTTLE LABEL HAD BEEN PARTIALLY REMOVED AND A LABEL THAT STATED "THINNER" HAD BEEN APPLIED TO THE BOTTLE.
Recommendation: Do not store chemicals in containers that were previously used for food or beverages.
Item No.: 30
Site: Other-MAIN GALLEY-ROOM SERVICE PANTRY
Violation: A "WASH HANDS OFTEN" SIGN WAS NOT POSTED OVER THE HANDWASH SINK.
Recommendation: 7.7.1.1.7 A sign stating "WASH HANDS OFTEN" in a language that the food employees understand shall be posted over handwashing sinks.
Item No.: 38
Site: Other-MAIN GALLEY
Violation: THE SMALL CLEANING LOCKER NEAR THE ELEVATORS WAS NOT LABELED.
Recommendation: 7.7.7.1.2 Maintenance tools such as mops, brooms, and similar items shall be stored in a designated locker so they do not contaminate food; food-contact surfaces of utensils; and equipment; linens, and single-service and single-use articles.
Item No.: 20
Site: Other-MAIN GALLEY-PASTRY/BAKERY
Violation: THE LID FOR THE EBERHARDT MIXER WAS CRACKED.
Recommendation: Replace the lid.
Item No.: 19
Site: Other-MAIN GALLEY-BAKERY/PASTRY
Violation: THE SUGAR BIN WAS NOT LABELED. THIS WAS CORRECTED AT THE TIME OF THE INSPECTION.
Recommendation: 7.3.3.2.3 Working containers holding food or food ingredients that are removed from their original packages for use on the vessel, such as cooking oils, flour, herbs, potato flakes, salt, spices, and sugar shall be identified with the common name of the food.
Item No.: 19
Site: Other-MAIN GALLEY-BAKERY/PASTRY
Violation: A FLY CATCHER WAS MOUNTED ON THE BULKHEAD BEHIND THE MIXER AND DOUGH PRESS MACHINE. THE FLY CATCHER WAS LESS THEN SIX INCHES FROM THE MIXER AND DOUGH PRESS MACHINE.
Recommendation: 8.2.2.2.2 The insect devices shall not be located over food storage, preparation, and service areas. Dead insects and insect fragments shall be prevented from being impelled onto or falling on exposed food.
Item No.: 26
Site: Other-MAIN GALLEY-BAKERY/PASTRY
Violation: THE SLICER WAS SLIGHTLY SOILED ALONG THE BACKPLATE.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 22
Site: Other-MAIN GALLEY-POTWASH
Violation: THE POTWASH MACHINE WAS OUT OF ORDER.
Recommendation: Repair this unit.
Item No.: 30
Site: Other-MAIN GALLEY-TOILET ROOM
Violation: A "WASH HANDS AFTER USING THE TOILET" SIGN WAS NOT POSTED IN THE TOILET ROOM. A COVERED WASTE RECEPTACLE WAS NOT PROVIDED IN THE TOILET ROOM.
Recommendation: 7.7.1.2.3 Signs shall be conspicuously posted on the bulkhead adjacent to the door of the toilet, reading "WASH HANDS AFTER USING TOILET " in a language that the food employees understand. 7.7.1.2.5 Easily cleanable covered receptacles shall be provided for hygiene waste materials.
Item No.: 33
Site: Other-MAIN GALLEY-HOT GALLEY
Violation: THE DECK AROUND THE DRAINS UNDER THE HOT LINE HAD ROUGH SURFACES AND CORRODED METAL MAKING THESE AREAS DIFFICULT TO CLEAN.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 34
Site: Other-CREW GALLEY
Violation: THE SPOUT FOR THE WATER FOUNTAIN WAS MISSING.
Recommendation: Repair this unit.
Item No.: 24
Site: Other-CREW DISHWASH
Violation: THE FINAL RINSE ARM WAS NOT SPRAYING. THE WATER WAS TRICKLING OUT OF THE NOZZLES. THIS UNIT WAS IN ACTIVE USE AT THE TIME OF THE INSPECTION.
Recommendation: Ensure that all of the nozzles are spraying adequately when warewash equipment is in use.
Item No.: 08
Site: Other-FOOD SERVICE GENERAL
Violation: VENTED BACKFLOW PREVENTION DEVICES WERE NOT INSTALLED ON THE POTABLE WATER LINES SUPPLYING THE HOOD CLEANING SYSTEMS IN THE GALLEYS. THE DEVICES INSTALLED DID NOT HAVE VENTS TO THE ATMOSPHERE.
Recommendation: Replace the devices with appropriate vented devices.
Item No.: 19
Site: Other-PROVISIONS CORRIDOR
Violation: A FLY CATCHER WAS MOUNTED DIRECTLY OVER SACKS OF DRY GOODS IN THE PROVISIONS CORRIDOR.
Recommendation: 8.2.2.2.2 The insect devices shall not be located over food storage, preparation, and service areas. Dead insects and insect fragments shall be prevented from being impelled onto or falling on exposed food.
Item No.: 33
Site: Other-PROVISIONS CORRIDOR
Violation: SACKS OF DRY GOODS WERE STORED IN THE PROVISIONS CORRIDORS. THE DECKHEAD WAS NOT FINISHED IN THIS AREA MAKING IT DIFFICULT TO CLEAN.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 19
Site: Other-PROVISIONS-DRY STORE REFRIGERATOR
Violation: AN OPEN BAG OF PRUNES WAS NOT PROPERLY CLOSED AFTER USE.
Recommendation: Tightly seal food bags after use.
Item No.: 19
Site: Other-PROVISIONS-CHEESE REFRIGERATOR
Violation: A BALL OF PECORINO CHEESE WAS NOT COVERED AFTER CUTTING.
Recommendation: Cover the cheese balls properly.
Item No.: 19
Site: Other-PROVISIONS-FROZEN VEGETABLE WALK-IN
Violation: AN OPEN BAG OF BLUEBERRIES WAS NOT PROPERLY SEALED AFTER USE.
Recommendation: Tightly seal food bags after use.
Item No.: 21
Site: Other-PROVISIONS-FISH FREEZER
Violation: EXCESS ICE WAS NOTED IN THIS UNIT AT THE ENTRANCE BEHIND THE SMALL DOOR.
Recommendation: Ensure that the door seal is adequate to prevent the accumulation of ice in this unit.
Item No.: 37
Site: Other-MAIN GALLEY-DISHWASH
Violation: CONDENSATE WAS NOTED OVER THE SOILED END OF THE WAREWASH UNIT. THIS WAS NOTED DURING THE LAST INSPECTION.
Recommendation: 7.4.3.2.1 Ventilation hood systems and devices shall be sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
Item No.: 27
Site: Other-CREW MESS
Violation: A LARGE WICKER BASKET WAS SOILED AND STORED AS CLEAN UNDER THE BEVERAGE COUNTER.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SEVEN SEAS NAVIGATOR- CAS - [09/03/2003] .
Recommendation:
Item No.: 20
Site: Other-PORTOFINO GALLEY
Violation: SLIGHT CORROSION WAS NOTED IN THE ICE BIN OF THE ICE MACHINE.
Recommendation: 7.4.1.1.2 Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
Item No.: 21
Site: Other-PORTOFINO GALLEY
Violation: EXCESSIVE AND PEELING SEALANT WAS NOTED IN THE DRIP PAN HOUSINGS OF THE GRILL AND THE FLAT-TOP GRILL.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 27
Site: Other-PORTOFINO GALLEY
Violation: THE DRIP PAN HOUSINGS OF THE GRILL AND THE FLAT TOP GRILL WERE SOILED WITH GREASE RESIDUE.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 28
Site: Other-PORTOFINO BUFFET
Violation: PLATES WERE NOT STORED COVERED OR INVERTED ON THE BUFFET LINE. THE BUFFET WAS CLOSED DURING THE TIME OF THE INSPECTION.
Recommendation: 7.5.7.3.2 Clean equipment and utensils shall be stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
Item No.: 29
Site: Other-POOL GRILL
Violation: A HANDWASH SINK WAS NOT LOCATED IN THIS AREA. THE HANDWASH SINK WAS LOCATED IN THE PANTRY REQUIRING PASSAGE THROUGH A CLOSED DOOR.
Recommendation: 7.7.1.1.1 Each food preparation area, bar, warewashing area, and garbage-processing area shall have at least one handwashing facility located in it. 7.7.1.1.2 The handwashing facility shall be located within 8 m (25 feet) of all parts of the area and should not be located in an adjacent area that requires passage through a closed door.
Item No.: 26
Site: Other-POOL GRILL
Violation: CARBONIZED FOOD RESIDUE WAS NOTED ON THE FRYER COILS.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 06
Site: Other-POTABLE WATER
Violation: ON 3/12/2003 FROM 12:00 AM TO 10:00 AM THE ANALYZER CHART RECORDER CHART SHOWED THE LEVEL OF FREE CHLORINE IN THE DISTRIBUTION SYSTEM TO BE 0 PPM. IT WAS STATED BY THE ENGINEER THAT THE PROBE HAD FAILED ON THE ANALYZER. A MANUAL TEST WAS NOT PERFORMED EVERY 4 HOURS DURING THIS TIME PERIOD AND THERE WAS NO DOCUMENTATION OF PROBE FAILURE ON THE CHART.
Recommendation: 5.5.3.1.1 Free residual halogen shall be measured by a manual test kit at the halogen analyzer at least every 4 hours in the event of equipment failure. 5.5.3.1.2 Manual readings shall be recorded on a chart or log, shall be retained for at least 12 months, and shall be available to the VSP for review during inspections.
Item No.: 08
Site: Other-POTABLE WATER
Violation: DURING POTABLE WATER PRODUCTION, IT WAS UNCLEAR IF A TEST OF THE FREE CHLORINE RESIDUAL WAS PERFORMED EVERY FOUR HOURS. THE TEST RESULTS WERE RECORDED IN A LOG BOOK THAT STATES THE WATCH TIMES (0000-0400, 0400-0800, ETC.) BUT THE ACTUAL TIME THE TEST WAS TAKEN WAS NOT RECORDED.
Recommendation: 5.2.1.2.2 Free residual halogen monitoring shall be performed at least hourly during the bunkering of potable water and performed at least once every 4 hours during the onboard production of potable water.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program