Cruise Ship: AIDAaura Cruise Line: Aida Cruises Inspection Date: 11/18/2003 Inspection Score: 99
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 29
Site: Other-MAIN GALLEY
Violation: THE WATER AT THE HANDWASH SINK OUTSIDE OF THE CHEF'S OFFICE DID NOT REACH 110°F. THIS WAS CORRECTED IMMEDIATELY.
Recommendation: 7.7.1.1.3 A handwashing sink shall be equipped to provide water at a temperature of at least 43°C (110°F) through a mixing valve or combination faucet.
Item No.: 28
Site: Other-MAIN GALLEY
Violation: THE COFFEE CARAFES IN THE COFFEE STATION FOR THE MARKET RESTAURANT WERE NOT STORED INVERTED TO ALLOW WATER TO DRAIN FROM THEM.
Recommendation: 7.5.7.1.1 After cleaning and sanitizing, equipment and utensils shall be air-dried or adequately drained before contact with food.
Item No.: 13
Site: Other-MAIN GALLEY
Violation: A PAN OF COOKED CHICKEN WAS FOUND IN REFRIGERATOR #37 IN THE HOT GALLEY WITH A TEMPERATURE OF 9°C. A PAN OF COOKED RICE WAS FOUND IN THE SAME REFRIGERATOR WITH A TEMPERATURE OF 10°C. THE CHEF STATED THAT THE ITEMS HAD BEEN PLACED IN THE REFRIGERATOR 3 HOURS PRIOR TO THE TEMPERATURES BEING TAKEN. THE FOOD WAS DISCARDED IMMEDIATELY. A REVIEW OF THE BLAST CHILLER LOGS SHOWED THAT FOOD PLACED IN THE BLAST CHILLER THE NIGHT PRIOR TO THE INSPECTION WAS LEFT OVERNIGHT WITHOUT THE TEMPERATURES BEING MONITORED. THE FOOD WAS PLACED IN THE BLAST CHILLER AT 8:00 PM AT 180°F AND WAS CHECKED AT 8:00 AM WITH A TEMPERATURE OF 40°F.
Recommendation: 7.2.1.2.1.7 The person in charge of the food operations on the vessel shall ensure that: (7) Employees are using proper methods to rapidly cool potentially hazardous foods that are not held hot or are not for consumption within 4 hours, through daily oversight of the employees' routine monitoring of food temperatures during cooling.
Item No.: 22
Site: Other-MAIN GALLEY
Violation: THE POTWASH MACHINE WAS POSTED OUT OF ORDER.
Recommendation: Repair or replace this unit.
Item No.: 30
Site: Other-MAIN GALLEY
Violation: THE RESTROOM LOCATED BY THE CHEF'S OFFICE FOR USE BY GALLEY EMPLOYEES DID NOT HAVE A SIGN POSTED STATING "WASH HANDS AFTER USING TOILET". A COVERED WASTE RECEPTACLE WAS NOT PROVIDED IN THIS TOILET ROOM.
Recommendation: 7.7.1.2.3 Signs shall be conspicuously posted on the bulkhead adjacent to the door of the toilet, reading "WASH HANDS AFTER USING TOILET " in a language that the food employees understand. 7.7.1.2.5 Easily cleanable covered receptacles shall be provided for hygiene waste materials.
Item No.: 30
Site: Other-MARKET RESTAURANT
Violation: A SIGN STATING "WASH HANDS OFTEN" WAS NOT POSTED AT THE HANDWASH SINK LOCATED OUTSIDE OF GALLEY ENTRANCE 8451K AND AT THE HANDWASH SINK IN THE ANTIPASTI STATION.
Recommendation: 7.7.1.1.7 A sign stating "WASH HANDS OFTEN" in a language that the food employees understand shall be posted over handwashing sinks.
Item No.: 20
Site: Other-CREW GALLEY
Violation: REFRIGERATOR #53 WAS POSTED OUT OF ORDER.
Recommendation: Repair or replace this unit.
Item No.: 20
Site: Other-CREW MESS
Violation: TWO MILK DISPENSERS AND THE MICROWAVE WERE POSTED OUT OF ORDER.
Recommendation: Repair or replace these units.
Item No.: 16
Site: Other-FOOD SERVICE GENERAL
Violation: DISCARD DATES WERE NOT WRITTEN ON THE REFRIGERATED, READY-TO-EAT, POTENTIALLY HAZARDOUS FOODS. THE PREPARATION DATE WAS WRITTEN INSTEAD.
Recommendation: None: 7.3.5.3.1 Refrigerated, ready-to-eat, potentially hazardous food: (1) Prepared on a vessel and held refrigerated for more than 24 hours shall be clearly marked at the time of preparation to indicate the date by which the food shall be consumed, which is, including the day of preparation, 7 calendar days or fewer from the day the food is prepared.
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: AIDAAURA - CAS - 11/18/2003.
Recommendation:
Item No.: 06
Site: Other-POTABLE WATER
Violation: THE HALOGEN ANALYZER-CHART RECORDER CHARTS DID NOT HAVE A RANGE OF 0.0 TO 5.0 (PPM).
Recommendation: 5.5.2.1.1 Halogen analyzer-chart recorder charts shall have a range of 0.0 to 5.0 mg/L (ppm) and have a recording period of 24 hours.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE VESSEL DID NOT HAVE A COMPREHENSIVE CROSS-CONNECTION CONTROL PROGRAM IN PLACE.
Recommendation: 5.7.1.1.3 The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
Item No.: 08
Site: Other-POTABLE WATER
Violation: A PH TEST WAS NOT BEING CONDUCTED ON A REGULAR BASIS ON THE SHORE SIDE WATER SUPPLY BEFORE BUNKERING.
Recommendation: 5.2.1.2.1 A halogen demand test and pH shall be conducted on the shore-side water supply before starting the bunkering process to establish the correct halogen dosage.
Item No.: 08
Site: Other-POTABLE WATER
Violation: FREE RESIDUAL HALOGEN MONITORING WAS NOT BEING PERFORMED EVERY HOUR ON A REGULAR BASIS DURING BUNKERING.
Recommendation: 5.2.1.2.2 Free residual halogen monitoring shall be performed at least hourly during the bunkering of potable water and performed at least once every 4 hours during the onboard production of potable water.
Item No.: 41
Site: Other-CHILD ACTIVITY CENTER
Violation: WRITTEN GUIDANCE ON SYMPTOMS OF COMMON CHILDHOOD INFECTIOUS ILLNESSES WAS NOT MAINTAINED IN THE CHILD-ACTIVITY CENTER.
Recommendation: 10.4.1.1.1 Written guidance on symptoms of common childhood infectious illnesses shall be maintained in the child-activity center.
Item No.: 41
Site: Other-CHILD ACTIVITY CENTER
Violation: A WRITTEN POLICY ON PROCEDURES TO BE FOLLOWED WHEN A CHILD DEVELOPS SYMPTOMS OF AN INFECTIOUS ILLNESS WAS NOT MAINTAINED IN THE CHILD ACTIVITY CENTER.
Recommendation: 10.4.1.1.2 The child-activity center shall have a written policy on procedures to be followed when a child develops symptoms of an infectious illness while at the center.