Item No.:
33
|
|
Site:
Other-LE GRAND BLEU
|
|
Violation:
UNSEALED PIPE PENETRATIONS WERE BEHIND THE TAYLOR SOFT SERVE ICE CREAM MACHINE LOCATED ON THE PORT SIDE BUFFET LINE.
|
|
Recommendation:
7.7.4.1.1
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
|
|
|
Item No.:
22
|
|
Site:
Other-LE GRAND BLEU
|
|
Violation:
THE WASH TEMPERATURE GAUGE ON THE WAREWASH MACHINE WAS NOT EASILY READABLE DUE TO CONDENSATE.
|
|
Recommendation:
7.5.2.2.1
Water temperature measuring devices shall be designed to be easily readable.
|
|
|
Item No.:
33
|
|
Site:
Other-MAIN GALLEY - PORTSIDE SERVICE LINE
|
|
Violation:
LOOSE PROFILE STRIPS WERE NOTED ON THE BULKHEAD BEHIND THE SERVICE LINE.
|
|
Recommendation:
7.7.4.2.3
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair.
|
|
|
Item No.:
28
|
|
Site:
Other-MAIN GALLEY - POTWASH
|
|
Violation:
THE STORAGE SHELF OVER THE THREE COMPARTMENT SINK WAS USED TO STORE CLEAN POTS AND UTENSILS. THE SHELF WAS LOCATED OVER ALL THREE SINKS AND SUBJECTED THE CLEAN ITEMS OVER THE WASH AND RINSE SINK TO CONTAMINATION. THIS WAS NOTED ON THE LAST INSPECTION.
|
|
Recommendation:
7.5.7.3.1
Cleaned equipment and utensils, laundered linens, and single-service and single-use articles shall be stored:
(1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
41
|
|
Site:
Other-VENTILATION
|
|
Violation:
THE DRAIN PANS ON THE VENTILATION UNITS WERE VERY CORRODED.
|
|
Recommendation:
9.2.1.2.2
Evaporative condensers shall be inspected at least annually and cleaned as necessary to remove scale and sediment. Cooling coils and condensate pans shall be cleaned as necessary to remove dirt and organic material.
|
|
|
Item No.:
40
|
|
Site:
Other-INTEGRATED PEST MANAGEMENT
|
|
Violation:
CREDENTIALS/CERTIFICATES FOR THE INSTRUCTOR PROVIDING TRAINING FOR THE VESSEL WERE NOT AVAILABLE.
|
|
Recommendation:
8.1.2.1.3
The training of the pest-control personnel shall be documented in the Integrated Pest Management Plan.
|
|
|
Item No.:
33
|
|
Site:
Other-FOOD SERVICE GENERAL
|
|
Violation:
CRACKED AND BROKEN DECK TILES WERE NOTED THROUGHOUT THE FOOD SERVICE AREAS. RECESSED GROUTING WAS NOTED IN THE MAIN GALLEY.
|
|
Recommendation:
7.7.4.2.3
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair.
|
|
|
Item No.:
*
|
|
Site:
Other-CORRECTIVE ACTION STATEMENT
|
|
Violation:
IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY.
PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV
USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
|
|
Recommendation:
|
|