Item No.:
40
|
|
Site:
Other-INTEGRATED PEST MANAGEMENT (IPM)
|
|
Violation:
ALTHOUGH THE CHEF MAKES INSPECTIONS OF ONCOMING FOOD SHIPMENTS AND LOGS THE RESULTS, THERE IS NOTHING WRITTEN IN THE IPM PLAN ABOUT WHO MAKES THESE INSPECTIONS AND WHEN.
|
|
Recommendation:
Provide a statement that the Chef will make the inspection of incoming food shipments for pests at every provisioning of the ship in the IPM plan.
|
|
|
Item No.:
40
|
|
Site:
Other-INTEGRATED PEST MANAGEMENT (IPM)
|
|
Violation:
OLDER LOGS OF INSPECTIONS FOR PEST ACTIVITY INCLUDED ENTRIES OF TIME, SO NIGHT TIME INSPECTIONS COULD BE VERIFIED. THE NEW LOGS DON'T INCLUDE A TIME COLUMN AND THERE IS NO RECORD OF AT LEAST SOME INSPECTIONS BEING MADE AT NIGHT.
|
|
Recommendation:
Recommend that night time inspections be documented in the pest monitoring inspection logs.
8.1.1.1.2
The Integrated Pest Management Plan shall set a schedule for periodic monitoring inspections including some at night.
|
|
|
Item No.:
06
|
|
Site:
Other-POTABLE WATER - PRODUCTION
|
|
Violation:
THE BUNKERING/PRODUCTION HALOGEN ANALYZER CHARTS HAD A RECORDING RANGE OF 0-100, BUT THE ACTUAL RANGE OF MEASURE IS 0-5 PPM, BASED ON THE TESTS MADE BY THE ONBOARD ENGINEERS.
|
|
Recommendation:
Change the recorder charts to a type which gives direct increments beginning with 0 ppm.
|
|
|
Item No.:
06
|
|
Site:
Other-POTABLE WATER - PRODUCTION
|
|
Violation:
MANY OF THE RECENT PRODUCTION HALOGEN ANALYZER CHARTS HAD NO INDICATION OF CALIBRATION WRITTEN ON THE CHART AND THERE WAS NO SEPARATE LOG ENTRY EITHER.
|
|
Recommendation:
5.2.1.2.4
Halogen analyzer-chart recorders used in lieu of manual tests and logs shall be calibrated at the beginning of bunkering or production, and the calibration shall be recorded on the chart or in a log book.
|
|
|
Item No.:
07
|
|
Site:
Other-POTABLE WATER - TANKS
|
|
Violation:
THE POTABLE WATER TANKS SHARE A WALL WITH THE HULL OF THE SHIP. A VARIANCE REQUEST WAS SUBMITTED BY THE COMPANY AND IS UNDER REVIEW BY THE VSP. RECORDS OF THE MONITORING ALREADY BEGUN ONBOARD WERE REVIEWED DURING THE INSPECTION.
|
|
Recommendation:
5.3.1.1.1
Potable water tanks shall not share a common wall with the hull of the vessel or with tanks containing non-potable water or other liquids.
|
|
|
Item No.:
08
|
|
Site:
Other-POTABLE WATER - BACKFLOW PROTECTION
|
|
Violation:
THE INTERNATIONAL SHORE CONNECTIONS FOR THE SHIP'S FIRE SYSTEM WERE NOT PROTECTED WITH REDUCED PRESSURE ASSEMBLY BACKFLOW PREVENTERS. THE PURCHASE ORDER WAS REVIEWED AND THE BACKFLOW PREVENTERS SHOULD ARRIVE FOR INSTALLATION WITHIN 10 DAYS.
|
|
Recommendation:
5.7.1.1.3
The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present:
(1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
|
|
|
Item No.:
08
|
|
Site:
Other-POTABLE WATER - BACKFLOW PREVENTION
|
|
Violation:
THE FLEXIBLE SHOWER HOSES IN ALL THE PASSENGER CABINS WERE NOT PROTECTED FROM BACKSIPHONAGE WITH A BACKFLOW PREVENTER. THIS IS A REPEAT ITEM FROM THE 16 MARCH INSPECTION.
|
|
Recommendation:
5.7.1.1.3
The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present:
(1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
|
|
|
Item No.:
41
|
|
Site:
Other-AIR SYSTEMS - VENTILATION FAN ROOMS
|
|
Violation:
ALTHOUGH THE CONDENSATE DRAIN PANS IN THE AIR-CONDITIONING FAN UNITS ARE ACCESSIBLE, FAN UNIT #3 HAD A CONDENSATE COLLECTION PAN WHICH WAS CORRODING AND BECOMING DIFFICULT TO CLEAN.
|
|
Recommendation:
9.2.1.2.1
Air handling units shall be kept clean. Recommend thorough de-scaling and cleaning of each such unit.
|
|
|
Item No.:
28
|
|
Site:
Other-TOP OF THE YACHT BAR - PANTRY #6
|
|
Violation:
THE CLEAN GLASS RACK WAS SUBJECT TO SPLASH FROM THE ADJACENT 3 BUCKETS STORED AND THE HANDWASH STATION. PROVIDE A SHIELD ON THE PORT SIDE OF THE CLEAN GLASS STORAGE RACK.
|
|
Recommendation:
7.5.7.3.1
Cleaned equipment and utensils, laundered linens, and single-service and single-use articles shall be stored:
(1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and
(3) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
20
|
|
Site:
Other-TOP OF THE YACHT BAR - PANTRY #6
|
|
Violation:
THE ABSORBENT GASKET WHERE THE UPPER ICE MAKER JOINS THE BIN OF THE ICE MACHINE WAS DIFFICULT TO CLEAN AND RELEASED WATER WHEN TOUCHED.
|
|
Recommendation:
7.4.1.1.2
Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be:
(1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
Remove and replace the gasket with a non-absorbent and easy to clean material.
|
|
|
Item No.:
26
|
|
Site:
Other-TOP OF THE YACHT BAR - PANTRY #6
|
|
Violation:
THERE WAS MOLD RESIDUE PRESENT ALONG THE FRONT PANEL OF THE ICE MACHINE CUBER SECTION NEAR THE WATER TRAY AND PASSING ALONG THE CHUTE PANEL BELOW.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
33
|
|
Site:
Other-TOP OF THE YACHT BAR
|
|
Violation:
THERE WAS A LARGE GAP ALONG THE FORWARD/STARBOARD CORNER OF THE BAR COUNTER AT THE DECK.
|
|
Recommendation:
Completely profile the opening with stainless steel and cove the juncture at the deck.
|
|
|
Item No.:
21
|
|
Site:
Other-TOP OF THE YACHT BAR
|
|
Violation:
A STAGNANT, MOLDY WASTEWATER WAS PONDING ON THE DECK AT THE FORWARD STARBOARD SIDE UNDERCOUNTER TECHNICAL COMPARTMENT.
|
|
Recommendation:
7.4.2.4.6
Equipment compartments that are subject to accumulation of moisture because of conditions such as condensation, food or beverage drip, or water from melting ice shall be sloped to an outlet that allows complete draining.
|
|
|
Item No.:
21
|
|
Site:
Other-TOP OF THE YACHT BAR
|
|
Violation:
THERE WAS STAGNANT, DIRTY WASTEWATER POOLING ON THE DECK IN THE AFT UNDERCOUNTER TECHNICAL COMPARTMENT. THERE WAS A DECK SINK PRESENT IN THE COMPARTMENT, BUT IT HAD A RAISED COAMING WHICH PREVENTED THE SURROUNDING PART OF THE COMPARTMENT TO DRAIN THERE. IN ADDITION THE DECK SINK DRAIN HAD NO COVER, AND LARGE PIECES OF DEBRIS WERE CLOGGING THE DRAIN.
|
|
Recommendation:
7.4.2.4.6
Equipment compartments that are subject to accumulation of moisture because of conditions such as condensation, food or beverage drip, or water from melting ice shall be sloped to an outlet that allows complete draining.
|
|
|
Item No.:
19
|
|
Site:
Other-LIDO STARBOARD - COLD PANTRY #5
|
|
Violation:
THE NEWLY INSTALLED UTENSIL DIPPER WELL WAS INSTALLED DIRECTLY BENEATH THE PAPER TOWEL DISPENSER FOR THE ADJACENT HANDWASH SINK.
|
|
Recommendation:
Move the paper towel dispenser to a position where when reaching for the paper there is no contamination of food counters, food serving utensils, or food.
|
|
|
Item No.:
34
|
|
Site:
Other-LIDO PORT - PANTRY #5
|
|
Violation:
A WATER LEAK WAS PRESENT BELOW THE DISHWASH MACHINE.
|
|
Recommendation:
Repair the leak.
|
|
|
Item No.:
21
|
|
Site:
Other-LIDO PORT - HOT GALLEY
|
|
Violation:
THE OPEN CHANNEL AT THE ENTRY DOOR LOCK WAS AVAILABLE FOR INSECT HARBORAGE AND MADE CLEANING DIFFICULT.
|
|
Recommendation:
Close the gap at the door locking pin with an inverted nipple recess profile piece.
|
|
|
Item No.:
33
|
|
Site:
Other-LIDO PORT - HOT GALLEY
|
|
Violation:
BULKHEAD PENETRATIONS FOR THE FIRE SUPPRESSION WIRING WERE OPEN, PREVENTING CLEANING AND LEAVING ACCESS FOR PESTS. THE BULKHEAD MOUNTED FIRE SUPPRESSION SYSTEM CONTROL BOX HAD A LARGE HOLE FOR A PIPE PENETRATION WHICH ALSO SHOULD BE SEALED.
|
|
Recommendation:
7.7.4.1.7
Exposed utility service lines and pipes, including lines for fire detection and protection systems, shall be installed so they do not obstruct or prevent cleaning.
|
|
|
Item No.:
26
|
|
Site:
Other-LIDO PORT - PANTRY #5
|
|
Violation:
THE PREVIOUSLY CLEANED DEEP FRYER COILS WERE SOILED WITH BURNED ON GREASE DEPOSITS.
|
|
Recommendation:
|
|
|
Item No.:
36
|
|
Site:
Other-PANTRIES #3 AND 4
|
|
Violation:
THE ARTIFICIAL LIGHTING AT THE SINKS IN THESE LOCATIONS WERE BELOW THE MINIMUM 220 LUX (20 FOOT CANDLES).
|
|
Recommendation:
7.7.5.1.1
The light intensity shall be at least 220 Lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
33
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
THE JUNCTURE AT THE BULKHEAD AND DECK ALONG THE STARBOARD SIDE WAS SOILED WITH A BLACK MOLD RESIDUE.
|
|
Recommendation:
7.7.4.2.1
Decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, shall be cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Other-MAIN GALLEY - GENERAL
|
|
Violation:
BULKHEAD AND DECKHEAD ATTACHED SWITCHES, BOXES, WIRES, AND VENT COVERS MADE PROPER CLEANING DIFFICULT. SOME SUCH ATTACHED EQUIPMENT WAS ALSO SOILED WITH DUSTAND GREASE RESIDUE.
|
|
Recommendation:
7.7.4.1.6
Light fixtures, vent covers, and similar equipment attached to the bulkheads or deckheads shall be easily cleanable.
|
|
|
Item No.:
36
|
|
Site:
Other-PROVISIONS
|
|
Violation:
ARTIFICIAL LIGHT LEVELS AT THE ENTRY OF THE FISH WALK-IN FREEZER AND THROUGHOUT THE DRY STORES WALK-IN WERE BELOW 110 LUX (10 FOOT CANDLES).
|
|
Recommendation:
7.7.5.1.2
The light intensity shall be at least 110 Lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning.
|
|
|
Item No.:
28
|
|
Site:
Other-MAIN GALLEY - POT WASH
|
|
Violation:
THE CURRENT ARRANGEMENT HAS A CLEAN DISHWARE RACK DIRECTLY IN FRONT OF THE WASH SINK AND SOME CLEANED STRAINERS HANGING DIRECTLY OVER THE WASH SINK. RECOMMEND INSTALLING A SHIELD ON THE CLEAN RACK SECTION FACING THE WASH SINK AND NOT STORING OR HANGING ANY CLEAN ITEMS OVER THAT SINK.
|
|
Recommendation:
7.5.7.3.1
Cleaned equipment and utensils, laundered linens, and single-service and single-use articles shall be stored:
(1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and
(3) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
15
|
|
Site:
Other-FOOD SERVICE GENERAL
|
|
Violation:
THE ST. THOMAS DAIRIES HALF AND HALF PRODUCT AND MILK IDENTIFIED IN PROVISIONS STORES DOES NOT COMPLY WITH GRADE 'A' STANDARDS AS SPECIFIED IN LAW. RECOMMEND DISCARDING THESE PRODUCTS IMMEDIATELY AND ESTABLISHING A GRADE 'A' APPROVED MILK PRODUCT FROM A VENDOR WHICH DOES COMPLY WITH THE LEGAL GRADE A STANDARDS.
|
|
Recommendation:
7.3.2.2.4
Eggs and milk products shall be received as follows:
(1) Liquid, frozen, and dry eggs and egg products shall be obtained pasteurized. (2) Fluid and dry milk and milk products complying with Grade A standards as specified in law shall be obtained pasteurized. (3) Frozen milk products, such as ice cream, shall be obtained pasteurized as specified in 21 CFR 135 Frozen Desserts. (4) Cheese shall be obtained pasteurized unless alternative procedures to pasteurization are specified in the CFR, such as 21 CFR 133 Cheeses and Related Cheese Products, for curing certain cheese varieties.
|
|
|
Item No.:
*
|
|
Site:
Other-COMMENT - CORRECTIVE ACTION STATEMENT
|
|
Violation:
IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY.
PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV
USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
|
|
Recommendation:
|
|