Item No.:
27
|
|
Site:
Other-CREW MESS
|
|
Violation:
THE TECHNICAL COMPARTMENT OF THE JUICE DISPENSER WAS SOILED. THIS WAS CORRECTED DURING THE INSPECTION.
|
|
Recommendation:
7.5.5.1.3
Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
33
|
|
Site:
Other-CREW MESS
|
|
Violation:
A FEW VINYL TILES WERE WARPED UNDER THE SERVICE COUNTER. SECTIONS OF THE DECK NEAR THE BULKHEAD WERE NOT TILED. A GAP WAS NOTED UNDER THE METAL COVE BASE.
|
|
Recommendation:
7.7.4.1.1
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
7.7.4.1.8
Surfaces subject to routine splashes, spillage or other soiling during normal use shall have easily cleanable features.
|
|
|
Item No.:
33
|
|
Site:
Other-OFFICER'S MESS
|
|
Violation:
THE BULKHEAD-DECK JUNCTURE UNDER THE COUNTER WAS NOT COVED.
|
|
Recommendation:
7.7.4.1.3
Bulkhead and deck junctures shall be coved.
|
|
|
Item No.:
20
|
|
Site:
Other-DECK 3 PREPARATION GALLEY
|
|
Violation:
SOFT SEALANT WAS NOTED ON THE BACK PLATE OF THE SLICER.
|
|
Recommendation:
7.4.1.1.2
Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be:
(1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
Use a sealant that dries to a hard, durable, and smooth finish.
|
|
|
Item No.:
21
|
|
Site:
Other-DECK 3 PREPARATION GALLEY
|
|
Violation:
THERE WERE GAPS AND LOOSE SEALANT UNDER THE TILT PANS.
|
|
Recommendation:
7.4.1.1.9
Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
27
|
|
Site:
Other-DECK 3 PREPARATION GALLEY
|
|
Violation:
THE AREA UNDER THE TILT PANS WAS SOILED WITH GREASE RESIDUE.
|
|
Recommendation:
7.5.5.1.3
Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
31
|
|
Site:
Other-POTWASH
|
|
Violation:
BLEACH WAS STORED ON THE RIGHT SIDE OF THE FINAL RINSE COMPARTMENT OF THE 3-COMPARTMENT SINK.
|
|
Recommendation:
7.6.2.1.2
Poisonous or toxic materials used in food area cleaning and maintenance shall be stored so they cannot contaminate food, equipment, utensils, linens, and single-service and single-use articles by separating the poisonous or toxic materials by storing in a cleaning materials locker.
|
|
|
Item No.:
28
|
|
Site:
Other-POTWASH
|
|
Violation:
CUTTING BOARDS WERE STACKED WHILE STILL WET.
|
|
Recommendation:
7.5.7.3.2
Clean equipment and utensils shall be stored:
(1) In a self-draining position that allows air drying; and (2) Covered or inverted.
|
|
|
Item No.:
21
|
|
Site:
Other-PROVISIONS-ICE CREAM FREEZER
|
|
Violation:
PEELING PAINT WAS NOTED ON THE EVAPORATOR PAN.
|
|
Recommendation:
7.4.1.1.9
Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
21
|
|
Site:
Other-PROVISIONS-CANNED DRY STORES
|
|
Violation:
CHIPPED PAINT WAS NOTED ON THE SHELVES USED FOR STORING CANNED GOODS.
|
|
Recommendation:
7.4.2.1.2
Nonfood-contact surfaces of equipment and utensils shall be designed and constructed to be durable and to retain their characteristic qualities under normal use conditions.
|
|
|
Item No.:
19
|
|
Site:
Other-OUTSIDE BBQ
|
|
Violation:
THE PAPER TOWEL DISPENSER WAS MOUNTED OVER THE CONDIMENT STATION.
|
|
Recommendation:
Move the dispenser to an area that is not over food or clean equipment storage.
|
|
|
Item No.:
33
|
|
Site:
Other-BISTRO SERVICE COUNTER
|
|
Violation:
A GAP WAS NOTED BETWEEN THE DECK AND THE WOOD PANEL IN THE TECHNICAL COMPARTMENT UNDER THE BAIN MARIE. THIS GAP WAS SOILED.
|
|
Recommendation:
7.7.4.1.1
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
7.7.4.2.1
Decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, shall be cleaned as often as necessary.
|
|
|
Item No.:
22
|
|
Site:
Other-BISTRO DISHWASH
|
|
Violation:
THE RIGHT FINAL RINSE NOZZLE WAS NOT SPRAYING.
|
|
Recommendation:
Ensure that all nozzles are spraying properly.
|
|
|
Item No.:
33
|
|
Site:
Other-PASTRY
|
|
Violation:
SOFT SEALANT WAS NOTED ALONG THE DECK AT THE BACK JUNCTURE OF REFRIGERATION UNIT 24.
|
|
Recommendation:
7.7.4.1.8
Surfaces subject to routine splashes, spillage or other soiling during normal use shall have easily cleanable features.
|
|
|
Item No.:
20
|
|
Site:
Other-FOOD SERVICE GENERAL
|
|
Violation:
THE FOOD CONTACT AREAS OF SEVERAL PIECES OF OLDER EQUIPMENT SUCH AS ICE MACHINES, THE BISTRO FRYER, AND THE PASTRY OVENS WERE NOTED TO HAVE SLOTTED FASTENERS.
|
|
Recommendation:
7.4.2.2.1
Multiuse food-contact surfaces shall be:
(1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
|
|
|
Item No.:
10
|
|
Site:
Other-SPAS
|
|
Violation:
A MONTHLY INSPECTION AND SEDIMENTATION TEST WAS NOT CONDUCTED ON THE GRANULAR FILTERS.
|
|
Recommendation:
6.3.1.1.5
The granular filters shall be opened at least monthly and examined for cracks, mounds, or holes in the filter media. A core sample of the filter media shall be inspected for excessive organic material accumulation using a recommended sedimentation method.
|
|
|
Item No.:
10
|
|
Site:
Other-AFT AND TOP POOLS
|
|
Violation:
ANTI-VORTEX DRAIN COVERS WERE NOT PROVIDED AT THE POOLS.
|
|
Recommendation:
6.4.1.2.2
Anti-vortex drain covers shall be provided on swimming pools and whirlpool spas.
VERIFY THAT THE SIZE OF THE DRAIN COVERS PROVIDES THE EQUIVALENT PROTECTION AS ANTI-VORTEX DRAIN COVERS WOULD PROVIDE.
|
|
|
Item No.:
01
|
|
Site:
Other-MEDICAL
|
|
Violation:
THE 24-HOUR PRIOR TO ARRIVAL REPORT WAS MADE ON 11/28 AT 11:28 P.M. FOR AN ARRIVAL ON 11/30 AT 8 A.M. THIS REPORT WAS MORE THAN 30 HOURS PRIOR TO ARRIVAL.
|
|
Recommendation:
|
|
|
Item No.:
*
|
|
Site:
Other-CORRECTIVE ACTION STATEMENT
|
|
Violation:
IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY.
PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV
USE EMAIL MESSAGE SUBJECT LINE: WIND SURF- CAS - [11/30/2003] .
|
|