Cruise Ship: Seven Seas Navigator Cruise Line: Regent Seven Seas Inspection Date: 01/07/2001 Inspection Score: 98
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 06
Site: Other-POTABLE WATER
Violation: THE TEST USED TO TEST FOR E. COLI WAS NOT IN ACCORDANCE WITH "STANDARD METHODS FOR THE EXAMINATION OF WATER AND WASTEWATER".
Recommendation: Samples shall be analyzed utilizing a method accepted in Standard Methods for the Examination of Water and Wastewater.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE COMPUTER LOG FOR THE MAINTENANCE OF THE POTABLE WATER TANKS DID NOT LIST DISINFECTION AS A PROCEDURE WHEN THE TANKS WERE EITHER CLEANED OR MAINTAINED.
Recommendation: The tanks should be disinfected whenever they are cleaned or after maintenance if that procedure has the potential of contaminating the tanks.
Item No.: 10
Site: Other-POOLS AND SPAS
Violation: VERIFY THAT THE POOL AND SPA DRAIN COVERS ARE ANTI-VORTEX.
Recommendation:
Item No.: 33
Site: Other-LIDO-DINING AREA
Violation: THE CARPET AROUND THE FLAMBE AREA WAS STAINED.
Recommendation: Provide an easy to clean floor covering, such as hard tile, in front of the working area of the flambe station.
Item No.: 33
Site: Other-GALELEO BAR
Violation: THE GROUT AROUND THE CEILING SUPPORT WAS IN DISREPAIR.
Recommendation: Re-grout this area to provide a smooth and easy to clean surface.
Item No.: 37
Site: Other-MAIN GALLEY-DISHWASH/GLASSWASH
Violation: CONDENSATE WAS COLLECTING INSIDE THE HOOD ON THE SOILED SIDE OF THE DISHWASH UNIT AND ON THE ADJACENT DECKHEAD.
Recommendation: Ventilation hood systems and devices shall be sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
Item No.: 21
Site: Other-MAIN GALLEY-DISHWASH/GLASSWASH
Violation: THE ACCESS DOOR TO THE FINAL RINSE/DRYING COMPARTMENTS OF THE DISHWASH UNIT WAS IN DISRPAIR.
Recommendation: Repair the door so that it does not fall off its hinge when opened.
Item No.: 21
Site: Other-MAIN GALLEY-COLD GALLEY
Violation: DUCT TAPE WAS USED TO REPAIR/SEAL THE WALK-IN UNIT GASKET.
Recommendation: Do not use duct tape to repair/seal gaskets.
Item No.: 21
Site: Other-MAIN GALLEY-SOUP GALLEY
Violation: LOOSE AND PEELING SOFT SEALANT WAS NOTED ON THE KETTLES.
Recommendation: Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Other-MAIN GALLEY-PASTRY
Violation: EXCESS WATER WAS NOTED INSIDE THE COLLAR OF THE MIXER. SLIGHT CORROSION WAS NOTED ON THE INNER SURFACES OF THE COLLAR.
Recommendation: When cleaning this unit take special care to prevent water from collecting inside of the collar. This should help prevent further corrosion.
Item No.: 19
Site: Other-MAIN GALLEY-PASTRY
Violation: A COFFEE CUP WAS USED TO DISPENSE THE IMPROVER RATHER THAN A SCOOP.
Recommendation: Use a scoop or long handled utensil for dispensing the improver.
Item No.: 21
Site: Other-MAIN GALLEY-PASTRY
Violation: THE SECTION OF THE DOUGH ROLLER RAMP UNDERNEATH THE BELT WAS WET. THE BELT WAS CONSTRUCTED OF A MATERIAL THAT IMPEDED AIR-DRYING OF THE RAMP UNDERNEATH IT. THIS CONDITION CAN PROMOTE THE GROWTH OF MOLD ON THE UNDERSURFACE OF THE BELT.
Recommendation: The ramp underneath the belt is a non-food contact surface and as such can be dried with a clean cloth.
Item No.: 22
Site: Other-MAIN GALLEY-PASTRY
Violation: A SPONGE WAS NOTED IN THE SANITIZE BUCKET OF THE THREE-BUCKET SYSTEM.
Recommendation: Use a clean cloth in this bucket rather than a sponge.
Item No.: 33
Site: Other-MAIN GALLEY-CREW TOILET ROOM
Violation: GAPS AND LOOSE PROFILE STRIPS WERE NOTED ON THE BULKHEAD BEHIND THE TOILET.
Recommendation: Reattach the loose profile strips and eliminate the gaps in the bulkhead.
Item No.: 33
Site: Other-PROVISIONS-ELEVATOR
Violation: GAPS WERE NOTED AT THE BULKHEAD-DECK JUNCTURE.
Recommendation: Provide cove base in this area to eliminate the gap.
Item No.: 33
Site: Other-PROVISIONS-ELEVATOR
Violation: THE DECK WAS CORRODED AND HAD PEELING PAINT ON ITS SURFACES.
Recommendation: Provide a durable, hard, and easy to clean floor covering in the elevator.
Item No.: 20
Site: Other-ICE MACHINES
Violation: SLIGHT CORROSION WAS NOTED IN THE ICE/WATER CONTACT SURFACES OF THE ICE MACHINES.
Recommendation: Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
Item No.: 30
Site: Other-CREW MESS-TOILET ROOM
Violation: PAPER TOWELS WERE NOT PROVIDED AT THE HANDWASH SINK.
Recommendation: Provide paper towels at the handwash sink.
Item No.: 32
Site: Other-CREW MESS-TOILET ROOM
Violation: FOOD WASTE WAS NOTED IN THE OPEN WASTE RECEPTACLE IN THE TOILET ROOM. A COVERED WASTE RECEPTACLE WAS NOT PROVIDED IN THE TOILET ROOM.
Recommendation: Provide a covered waste receptacle in the toilet room.
Item No.: 38
Site: Other-CREW MESS-TOILET ROOM
Violation: A MOP WAS STORED ON THE DECK IN THE TOILET ROOM.
Recommendation: Provide an adequate storage locker for the mop and any other cleaning equipment needed in this area.
Item No.: 19
Site: Other-CREW MESS
Violation: THE HANDLES OF THE BREAD TONGS WERE IN DIRECT CONTACT WITH THE BREAD.
Recommendation: Store the tongs outside of the bread container. Provide longer tongs for dispensing the bread.
Item No.: 21
Site: Other-CREW GALLEY
Violation: THE SEALANT WAS PEELING ON THE NON-FOOD CONTACT SURFACES OF THE KETTLE.
Recommendation: Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Other-CREW GALLEY
Violation: THE SEALANT WAS PEELING ON THE NON-FOOD CONTACT SURFACES OF THE TILTING PAN. SEALANT WAS NOT NEEDED IN THIS AREA.
Recommendation: Remove the sealant.
Item No.: 33
Site: Other-CREW BUFFET
Violation: THE SEALANT APPLIED TO THE DECK-BUFFET JUNCTURE WAS PEELING.
Recommendation: Provide adequate coving at the deck-buffet juncture.
Item No.: 38
Site: Other-PROVISIONS-CORRIDOR
Violation: CLEANING EQUIPMENT WAS STORED AGAINST BOXES OF RICE AND SACKS OF FLOUR IN THE PROVISIONS CORRIDOR OUTSIDE OF THE PROVISIONS MASTER'S OFFICE.
Recommendation: Maintenance tools such as mops, brooms, and similar items shall be stored in a designated locker so they do not contaminate food; food-contact surfaces of utensils; and equipment; linens, and single-service and single-use articles.
Item No.: 33
Site: Other-PROVISIONS-FISH PREPARATION ROOM
Violation: THE SEALANT AT THE BULKHEAD-DECK JUNCTURE WAS SEPARATING FROM THE BULKHEAD CREATING A GAP.
Recommendation: Reapply the sealant to eliminate the gap.
Item No.: 18
Site: Other-PROVISIONS-MEAT FREEZER
Violation: RAW GROUND TURKEY PATTIES WERE STORED OVER RACKS OF LAMB, AND HAMBURGER PATTIES IN THE MEAT FREEZER.
Recommendation: Food shall be protected from cross-contamination by: (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry during storage, preparation, holding, and display by using separate equipment for each type, or arranging each type of food in equipment so that cross-contamination of one type with another is prevented, and preparing each type of food at different times or in separate areas.
Item No.: 38
Site: Other-PROVISIONS-TROLLEY WASH
Violation: THE MOP STORED IN THIS AREA WAS NOT HUNG TO DRY.
Recommendation: After use, mops shall be placed in a position that allows them to air-dry without soiling walls, equipment, or supplies.
Item No.: 33
Site: Other-CREW BAR
Violation: SLIGHT CORROSION WAS NOTED IN THE AREA AROUND THE DRAIN UNDERNEATH THE HANDWASH SINK.
Recommendation: Refinish this area to remove the corrosion.
Item No.: 26
Site: Other-FOOD SERVICE-GENERAL
Violation: THE MILK NOZZLES ON THE CAPPUCCINO MACHINES WERE SOILED. THE NOZZLES WERE PLACED ON SO TIGHTLY THAT A TOOL WAS NEEDED TO REMOVE THEM. THE INDIVIDUALS RESPONSIBLE FOR CLEANING THE MACHINES DID NOT HAVE THE TOOL NEEDED TO REMOVE THE NOZZLES.
Recommendation: Remove and clean the nozzles at the end of each meal service. Hand tighten the nozzles or provide tools for the cleaning staff so that the nozzles can be easily removed during cleaning.
Item No.: 15
Site: Other-FOOD SERVICE-GENERAL
Violation: USE A RECORD KEEPING SYSTEM FOR THE SHELLSTOCK TAGS THAT CORRELATES THE TAGS TO THE DATES WHEN THE SHELLSTOCK WAS SERVED.
Recommendation:
Item No.: *
Site: Other-FOOD SERVICE-GENERAL
Violation: OBTAIN THE MANUFACTURER'S MANUAL FOR THE ICE MACHINE/DISPENSER UNIT SO THAT A CLEANING SCHEDULE CAN BE DETERMINED FOR THE ICE/WATER CONTACT SURFACES OF THE BARREL.
Recommendation:
Item No.: *
Site: Other-FOOD SERVICE-GENERAL
Violation: THE TEMPERATURES OF POTENTIALLY HAZARDOUS HOT AND COLD FOODS WERE WELL MAINTAINED. OVERALL THE FOOD SERVICE AREAS OF THE VESSEL WERE MAINTAINED IN A CLEAN AND SANITARY MANNER.
Recommendation:
Item No.: *
Site: Other-MEDICAL
Violation: THE MEDICAL STAFF WERE DOING AN EXCELLENT JOB IN MEETING THE INTENT OF CHAPTER 4 OF THE VSP OPERATIONS MANUAL.
Recommendation:
Item No.: *
Site: Other-POTABLE WATER
Violation: THE RECORD KEEPING FOR THE POTABLE WATER SYSTEM WAS EXCELLENT.
Recommendation:
Item No.: 21
Site: Other-CREW BAR
Violation: EXCESS CONDENSATE WAS NOTED ON THE UNDERSURFACES OF THE HANDWASH SINK AND ON THE WALLS OF THE CABINET UNDER THE SINK.
Recommendation: Providing a direct connection to the deck drain at this handwash sink may help to eliminate the condensation.
Item No.: 21
Site: Other-FOOD SERVICE-GENERAL
Violation: THE ENDS OF THE HOLLOW GASKETS ON THE UPRIGHT REFRIGERATORS WERE NOT SEALED.
Recommendation: Seal the open ends of the hollow gaskets.
Item No.: 22
Site: Other-FOOD SERVICE-GENERAL
Violation: DATA PLATES WERE NOT PROVIDED FOR THE WAREWASHING UNITS IN THE GALLEYS AND BARS.
Recommendation: A warewashing machine shall be provided with an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operating specifications including the: (1) Temperatures required for washing, rinsing, and sanitizing; (2) Pressure required for the fresh water sanitizing rinse; and (3) Conveyor speed for conveyor machines or cycle time for stationary rack machines.
Item No.: 16
Site: Other-FOOD SERVICE-GENERAL
Violation: POTENTIALLY HAZARDOUS READY-TO-EAT FOODS HELD REFRIGERATED FOR MORE THAN 24 HOURS WERE NOT DATE MARKED AS REQUIRED.
Recommendation: Refrigerated, ready-to-eat, potentially hazardous food: (1) Prepared on a vessel and held refrigerated for more than 24 hours shall be clearly marked at the time of preparation to indicate the date by which the food shall be consumed, which is, including the day of preparation, 7 calendar days or fewer from the day the food is prepared. Refrigerated, ready-to-eat, potentially hazardous food: (2) A container of refrigerated, ready-to-eat potentially hazardous food prepared and packaged by a food processing plant shall be clearly marked, at the time the original container is opened, to indicate the date by which the food shall be consumed which is, including the day the original container is opened, 7 calendar days or fewer after the original container is opened.