Item No.:
06
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
FOUR RANDOM POTABLE WATER SAMPLES PER MONTH WERE NOT BEING COLLECTED AND ANALYZED FOR E. COLI.
|
|
Recommendation:
5.6.1.1.1
A minimum of four potable water samples per month shall be collected and analyzed for the presence of Escherichia coli. Samples shall be collected randomly from locations forward, aft, upper, and lower decks of the vessel.
|
|
|
Item No.:
06
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
THE MOST RECENT MICROBIOLOGICAL REPORT FOR BUNKERED WATER FROM SHORE WAS NOT AVAILABLE.
|
|
Recommendation:
5.1.1.2.1
Where available, the vessel shall have a copy of the most recent microbiologic report from each port before bunkering potable water to verify that the water meets potable standards.
|
|
|
Item No.:
10
|
|
Site:
Other- SPA'S
|
|
Violation:
THE FREE RESIDUE HALOGEN WAS NOT INCREASED TO 10 PPM IN THE SPAS AND CIRCULATED FOR AT LEAST 1 HOUR AT THE END OF EACH DAY.
|
|
Recommendation:
6.3.2.1.1
The free residual halogen shall be increased to at least 10.0 mg/L (ppm) in whirlpool spas and circulated for at least 1 hour at the end of each day.
|
|
|
Item No.:
10
|
|
Site:
Other-POOLS
|
|
Violation:
DEPTH MARKERS FOR THE POOL WERE NOT DISPLAYED PROMINENTLY SO THAT THEY COULD BE SEEN FROM THE DECK AND FROM THE POOL.
|
|
Recommendation:
6.4.1.1.2
Depth markers shall be installed for every 1 m (3 feet) in change of depth and shall be displayed prominently so they can be seen from the deck and from in the pool.
|
|
|
Item No.:
10
|
|
Site:
Other-POOLS
|
|
Violation:
ENSURE THAT ANTI-VORTEX DRAIN COVERS ARE PROVIDED FOR THE POOL.
|
|
Recommendation:
6.4.1.2.2
Anti-vortex drain covers shall be provided on swimming pools and whirlpool spas.
|
|
|
Item No.:
10
|
|
Site:
Other-POOL
|
|
Violation:
PROVIDE A SHEPHERDS HOOK AT THE POOL.
|
|
Recommendation:
6.4.1.2.1
Easy access shepherd's hook and approved floatation device shall be provided at a prominent location near each public swimming pool.
|
|
|
Item No.:
20
|
|
Site:
Other-GALLEY
|
|
Violation:
SOFT SEALANT WAS USED ON THE BACKPLATE OF THE SLICER.
|
|
Recommendation:
7.4.1.1.2
Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be:
(1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
|
|
|
Item No.:
21
|
|
Site:
Other-GALLEY
|
|
Violation:
THE INTERIOR SPACES OF THE FRYER WERE NOT EASILY CLEANABLE.
|
|
Recommendation:
7.4.2.2.6
Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Other-GALLEY
|
|
Violation:
AN OPEN CELLED, ABSORBENT GASKET WAS USED BETWEEN THE ICE MAKER AND THE ICE BIN.
|
|
Recommendation:
7.4.1.1.9
Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
27
|
|
Site:
Other-GALLEY
|
|
Violation:
THE JUNCTURE BETWEEN THE ICE MAKER AND THE ICE BIN WAS VERY CORRODED.
|
|
Recommendation:
7.5.5.1.3
Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
21
|
|
Site:
Other-VERANDA
|
|
Violation:
THE INTERIOR SPACES OF THE VITALITY JUICE MACHINE WAS NOT EASILY CLEANABLE.
|
|
Recommendation:
7.4.2.2.6
Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
27
|
|
Site:
Other-VERANDA
|
|
Violation:
THE INTERIOR SPACE OF THE VITALITY JUICE MACHINE WAS SOILED WITH A JUICE RESIDUE.
|
|
Recommendation:
7.5.5.1.3
Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
33
|
|
Site:
Other-LOUNGE BAR
|
|
Violation:
THE DECK WAS NOT COVED AT THE DECK/BULKHEAD JUNCTURE.
|
|
Recommendation:
7.7.4.1.3
Bulkhead and deck junctures shall be coved.
|
|
|
Item No.:
21
|
|
Site:
Other-LOUNGE BAR PANTRY
|
|
Violation:
THE TECHNICAL SPACE OF THE ICE MACHINE WAS SOILED AND HAD A SLIME MOLD GROWTH.
|
|
Recommendation:
7.4.2.2.6
Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
02
|
|
Site:
Other-MEDICAL
|
|
Violation:
THE LOGS FOR GASTROINTESTINAL ILLNESSES AND FOR ANTI-DIARRHEAL MEDICATION THAT IS DISPENSED DID NOT HAVE ALL THE REQUIRED DATA ELEMENTS.
|
|
Recommendation:
4.1.2.1.4
The gastrointestinal illness surveillance log entry for each passenger or crew member shall contain the following information:
(1) The first date of clinic visit or report to staff of illness; (2) The person's name, age and gender; (3) A designation as passenger or crew member; (4) Crew member position or job on the vessel, if applicable; (5) Cabin number; (6) Meal seating information; (7) Date and time of illness onset; (8) Illness symptoms, including the presence of the following selected signs and symptoms: numbers of episodes each of diarrhea and vomiting per day, bloody stools, fever, recorded temperature; (9) Notation on whether or not a stool specimen was requested and received; (10) Use of antidiarrheal medication; and (11) The presence of underlying medical conditions which may affect interpretation of acute gastrointestinal illness for example diabetic diarrhea, inflammatory bowel disease, gastrectomy or others.
4.1.2.1.5
A separate inventory of the daily total, by quantity and type, of antidiarrheal medications sold or dispensed to the passengers or crew members in all areas of the vessel shall be maintained alongside the gastrointestinal illness surveillance log.
|
|