Cruise Ship: Seven Seas Mariner Cruise Line: Regent Seven Seas Inspection Date: 08/01/2001 Inspection Score: 83
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 22
Site: Other-MAIN POT WASH
Violation: THE FINAL RINSE THERMOMETER FOR THE 3-COMPARTMENT SINK WAS 8° OUT OF CALIBRATION.
Recommendation: 7.5.2.1.1 Water temperature measuring devices: (1) That are scaled in Celsius or dually scaled in Celsius and Fahrenheit shall be designed to be accurate to ±1.5°C in the intended range of use. (2) That are scaled only in Fahrenheit shall designed to be accurate to ±3°F in the intended range of use. 7.5.2.1.1 Water temperature measuring devices: (1) That are scaled in Celsius or dually scaled in Celsius and Fahrenheit shall be designed to be accurate to ±1.5°C in the intended range of use. (2) That are scaled only in Fahrenheit shall designed to be accurate to ±3°F in the intended range of use.
Item No.: 20
Site: Other-MAIN GALLEY
Violation: THE BACK PLATE OF ONE SLICER CONTAINED A NON-EASILY CLEANABLE GAP.
Recommendation: 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches. 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 26
Site: Other-MAIN GALLEY
Violation: THE GAP ON THE BACK PLATE OF ONE SLICER WAS SLIGHTLY SOILED WITH FOOD RESIDUE.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 29
Site: Other-TERRACE CAFÉ BUFFET
Violation: THE PORTABLE OMELET STATIONS ON THE STARBOARD AND PORT BUFFET SIDES WERE 45 FEET AWAY FROM THE NEAREST HAND WASH STATION BEHIND THE BUFFET COUNTER.
Recommendation: 7.7.1.1.2 The hand washing facility shall be located within 8 m (25 feet) of all parts of the area and should not be located in an adjacent area that requires passage through a closed door.
Item No.: 19
Site: Other-TERRACE CAFÉ BUFFET
Violation: THE DRIED FRUIT AND NUT CEREAL TOPPING BOWLS WERE NOT FULLY SHIELDED AT THE PORT AND STARBOARD FRUIT AND CEREAL SECTIONS OF THE BUFFET COUNTER.
Recommendation: 7.3.3.6.1 Food on display shall be protected from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; or other effective means.
Item No.: 22
Site: Other-TERRACE CAFÉ GALLEY
Violation: SPONGES WERE USED IN THE SANITIZING BUCKETS. THIS ITEM WAS CORRECTED DURING THE INSPECTION.
Recommendation: 7.5.5.5.2 Sponges may not be used in contact with cleaned and sanitized or in-use food-contact surfaces.
Item No.: 19
Site: Other-TERRACE CAFÉ GALLEY
Violation: A FLYING INSECT GLUE TRAP DEVICE WAS MOUNTED DIRECTLY ABOVE THE PREPARATION/SERVICE COUNTER ALONG THE BEVERAGE STATION.
Recommendation: 8.2.2.2.2 The insect devices shall not be located over food storage, preparation, and service areas. Dead insects and insect fragments shall be prevented from being impelled onto or falling on exposed food.
Item No.: 21
Site: Other-TERRACE CAFÉ GALLEY
Violation: A DIFFICULT TO CLEAN PULL CURTAIN WAS INSTALLED AT THE PIZZA PASS-THRU SECTION.
Recommendation: The curtain shall be removed.
Item No.: 02
Site: Other-MEDICAL
Violation: THE STAFF WAS USING THE 1989 VSP OPERATIONS MANUAL DEFINITION OF A REPORTABLE CASE OF GASTROINTESTINAL ILLNESS.
Recommendation: 4.1.1.1.1 A reportable case of gastrointestinal illness shall be defined as: (1) Diarrhea (three or more episodes of loose stools in a 24 hour period); or (2) Vomiting and one additional symptom including one or more episodes of loose stools in a 24-hour period, or abdominal cramps, or headache, or muscle aches, or fever; and (3) Reported to the master of the vessel, the medical staff, or other designated staff by a passenger or a crew member.
Item No.: 33
Site: Other-MARINER LOUNGE
Violation: THE DECK AT THE BAR AND PANTRY ENTRY HAD SEAMS ALONG THE DOOR TRANSITION, A FEW CRACKED TILES, AND NO COVING WHERE THE DECK JOINS THE BAR AND THE DOOR.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 06
Site: Other-POTABLE WATER DISTRIBUTION
Violation: THE DISTRIBUTION SYSTEM CHLORINE ANALYZER IN THE ENGINE ROOM HAS BEEN MALFUNCTIONING FOR OVER 1 MONTH, SO THE CHLORINE PUMPS HAVE BEEN CONTROLLED MANUALLY. NO TECHNICAL SUPPORT FOR THE SYSTEM HAS BEEN PROVIDED, ALTHOUGH IT WAS REQUESTED BY THE CHIEF ENGINEER.
Recommendation: 5.4.1.1.1 All distribution water system halogenation devices shall be constructed and installed in accordance with recommended engineering practices.
Item No.: 04
Site: Other-POTABLE WATER DISTRIBUTION
Violation: THE BRIDGE CHLORINE CONCENTRATION WAS 7.4 PPM AT THE START OF THE INSPECTION. SEVERAL BRIDGE ANALYZER/RECORDER CHARTS HAD PERIODS OF OVER 4 HOURS WHERE THE CHLORINE CONCENTRATION REGISTERED OVER 5 PPM. THE CHLORINE CONCENTRATION WAS REDUCED TO 1.33 PPM DURING THE INSPECTION.
Recommendation: 5.4.1.2.1 The halogenation device shall provide continuous halogenation of the potable water distribution system and shall maintain a free residual halogen of 0.2 mg/L (ppm) and 5.0 mg/L (ppm) throughout the distribution system.
Item No.: 05
Site: Other-POTABLE WATER DISTRIBUTION
Violation: THE FINAL MANUAL TEST FOR FREE CHLORINE AT THE BRIDGE ANALYZER WAS 1.33 PPM. THE BRIDGE ANALYZER RECORDER MEASURED 2.16-2.2 PPM.
Recommendation: 5.5.1.2.3 The free residual halogen measured by the halogen analyzer shall be ±0.2 mg/L (ppm) of the free residual halogen measured by the manual test.
Item No.: 03
Site: Other-POTABLE WATER BUNKERING
Violation: THE FREE CHLORINE RESIDUAL OF THE POTABLE WATER LINE DURING ACTIVE BUNKERING WAS 1.10 PPM. A MANUAL TEST OF POTABLE WATER TANK 2212, WHICH WAS EMPTY PRIOR TO BUNKERING, MEASURED 0.75 PPM. THE CHLORINE LEVEL IN TANK 2212 WAS RAISED ABOVE 2.O PPM DURING THE INSPECTION.
Recommendation: 5.2.1.1.1 Potable water shall be continuously halogenated to at least 2.0 mg/L (ppm) free residual halogen at the time of bunkering or production with an automatic halogenation device.
Item No.: 03
Site: Other-POTABLE WATER BUNKERING/PRODUCTION
Violation: THE ANALYZER SYSTEM IN USE FOR BUNKERING IS MALFUNCTIONING AND CANNOT BE CALIBRATED. MANUAL TESTING AND PUMP ADJUSTMENTS HAVE BEEN MADE FOR OVER 1 MONTH. NUMEROUS RECORDS OF MANUAL TESTING DURING BUNKERING AND PRODUCTION OF POTABLE WATER SHOW CONCENTRATIONS BELOW 2.0 PPM, EVEN AFTER PUMP ADJUSTMENTS WERE MADE.
Recommendation: 5.2.1.1.1 Potable water shall be continuously halogenated to at least 2.0 mg/L (ppm) free residual halogen at the time of bunkering or production with an automatic halogenation device.
Item No.: *
Site: Other-FOOD SERVICE GENERAL
Violation: THE OVERALL CLEANLINESS, PROCEDURES, AND ATTENTION TO DETAILS IN THE GALLEYS, TERRACE CAFÉ, AND BARS WERE EXCELLENT
Recommendation: