Cruise Ship: Queen Victoria Cruise Line: Carnival UK LTD Inspection Date: 09/28/2009 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 16
Site: Galley-The Grills
Violation: The time as a public health control plan stated that these outlets were on temperature control. Per staff, the cold top and a few of the undercounter refrigeration units were on time control.
Recommendation: Ensure the time as a public health control plan reflects the food operation.
Item No.: 33
Site: Buffet-Portside Buffet
Violation: There was recessed grout where the stainless steel met the deck tiles in front of the grill.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 19
Site: Buffet-Portside Buffet
Violation: There were a few tongs that were not located under the sneezeguard at the dessert stations. This was corrected.
Recommendation: Ensure that each self-service food dispensing utensil is covered or located beneath shielding during service.
Item No.: 16
Site: Buffet-Pizzeria
Violation: The service time for this outlet was longer than 4 hours. There were logs indicating the time the food was placed on time control. However, there were no discard labels on the potentially hazardous foods.
Recommendation: Ensure discard labels are placed on the potentially hazardous food that are on time control.
Item No.: 26
Site: Galley-Deck 3 Room Service
Violation: The inside of the lids for the coffee carafes were soiled and wet.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 22
Site: Galley-Deck 2 Warewash
Violation: There were a few plates that were overlapping each other in the dishwash machine.
Recommendation: Ensure that soiled items to be cleaned in a warewashing machine are loaded into racks, trays, or baskets or onto conveyors in a position that: (1) Exposes the items to the unobstructed spray from all cycles; and (2) Allows the items to drain.
Item No.: 21
Site: Galley-Deck 2 Brittania Production Galley
Violation: The gaskets for the combination ovens were torn.
Recommendation: Replace the gaskets.
Item No.: 34
Site: Galley-Deck 2 Potwash
Violation: There was a leak at the supply line for the sanitize compartment of the three compartment sink.
Recommendation: Ensure that a plumbing system in a food area is maintained in good repair.
Item No.: 34
Site: Galley-Deck 2 Soup Station
Violation: There was a leak under the left square tilting kettle.
Recommendation: Ensure that a plumbing system in a food area is maintained in good repair.
Item No.: 20
Site: Preparation Room-
Violation: There were slotted fasteners inside the food contact areas of the potato peelers.
Recommendation: Replace the slotted fasteners with smooth, low-profile, non-corroding fasteners.
Item No.: 15
Site: Provisions-Shellstock Tags
Violation: The date of service was not recorded on the shellstock tags or shellstock records.
Recommendation: Ensure that shellstock shellfish tags: (1) Remain attached to the container in which the shellstock are received until the container is empty. (2) Are maintained by retaining shellstock tags or labels for 90 calendar days from the date the container is emptied by using an approved record keeping system that keeps the tags or labels in chronologic order correlated to the date when the shellstock are served.
Item No.: 37
Site: Galley-Hot Galley
Violation: An excessive amount of condensate had collected on the deckhead above the left tilting braising pan.
Recommendation: Ensure that ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.