Cruise Ship: Seadream I Cruise Line: Sea Dream Yacht Club Inspection Date: 11/07/2009 Inspection Score: 96
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 06
Site: Potable Water-
Violation: The ship could test for total coliforms for bunkering and the monthly microbiological tests of the potable water distribution system using the Colilert system. However, there was no black light to test for E. coli if there was a positive total coliform test result. There had been no positive total coliform test results.
Recommendation: Ensure that a minimum of four potable water samples per month are collected and analyzed for the presence of Escherichia coli and are collected randomly from locations on the forward, aft, upper, and lower decks of the vessel. Ensure that sample sites are changed each month.
Item No.: 08
Site: Potable Water-Hair Salon
Violation: The cross-connection control list indicated a Watts 9C for the backflow prevention device on the hot and cold water lines for the hair wash sink. It was unknown if this device is designed for use under continuous pressure.
Recommendation: Ensure that a continuous pressure-type backflow preventer is installed when a valve is located downstream from the backflow preventer.
Item No.: 06
Site: Potable Water-Production Records
Violation: According to the records, the calibration test for the analyzer chart recorder was conducted near the end of the production period for several days during the last cruise.
Recommendation: Ensure that halogen analyzer-chart recorders used in lieu of manual tests and logs are calibrated at the beginning of bunkering or production, and the calibration is recorded on the chart or in a log book.
Item No.: 08
Site: Potable Water-Cross-Connection Control Program
Violation: In the cross-connection control program, the backflow prevention device listed for the public toilets was "Jett". This was the type of vacuum system and not the type of device connected to the potable water lines to the toilets.
Recommendation: Ensure that the cross-connection control program includes at minimum: a complete listing of cross-connections and the backflow prevention method/device for each, so that there is a match to the plumbing system component and location, and an inspection frequency. Ensure that air-gaps are included in the listing.
Item No.: 33
Site: Pantry-Pantry #4
Violation: The upper shelf was separating from the deckhead, creating difficult to clean gaps at the connection points. Also, there were some holes in the surface of the deckhead.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 33
Site: Food Service General-
Violation: The deckheads and bulkheads in food service and food storage areas were difficult to clean due to attached piping and equipment, missing fasteners and other difficult to clean features.
Recommendation: Ensure that exposed utility service lines and pipes, including lines for fire detection and protection systems, are installed so they do not obstruct or prevent cleaning.
Item No.: 24
Site: Buffet-Pantry
Violation: The sanitizer concentration in the sanitizer bucket was less than 10ppm. This was corrected at the time of the inspection.
Recommendation: Ensure that a chlorine solution used as a sanitizing solution has a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
Item No.: 22
Site: Buffet-Pantry
Violation: The sanitizing solution in the sanitizer bucket was dirty.
Recommendation: Ensure that the wash, rinse, and sanitize solutions are maintained clean.
Item No.: 16
Site: Buffet-Pantry - Refrigerator # 1
Violation: Individual butter patties were measured at 48°F. The internal temperature of the unit was 40°F. The butter was placed in the blast chiller.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
Item No.: 08
Site: Buffet-Pantry
Violation: There was an atmospheric vacuum breaker type backflow preventer on the coffee machine. There was a valve downstream of the backflow preventer.
Recommendation: Ensure that a continuous pressure-type backflow preventer is installed when a valve is located downstream from the backflow preventer.
Item No.: 08
Site: Buffet-Topsider Grill
Violation: There was an atmospheric vacuum breaker type backflow preventer on the combination oven. There was a valve downstream of the backflow preventer.
Recommendation: Ensure that a continuous pressure-type backflow preventer is installed when a valve is located downstream from the backflow preventer.
Item No.: 33
Site: Buffet-Topsider Grill
Violation: The deck in the technical compartment below the service counter was peeling, flaking, and bubbled, making cleaning difficult.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 24
Site: Buffet-Topsider Grill
Violation: The final sanitizing rinse of the in-use, stationary rack dishwash machine was 141°F at the plate surface.
Recommendation: In a mechanical operation, ensure that the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F), or less than: (1) For a stationary rack, single temperature machine, 74°C (165°F); or (2) For all other machines, 82°C (180°F); or (3) A utensil surface temperature of 71°C (160°F) as measured by an irreversible registering temperature indicator shall be achieved. (4) The maximum temperature of 90°C (194°F), does not apply to the high pressure and temperature systems with wand-type, hand-held, spraying devices used for the in-place cleaning and sanitizing of equipment such as meat saws.
Item No.: 22
Site: Buffet-Topsider Grill
Violation: The externally mounted final rinse temperature gauge on the in-use, stationary-rack dishwash machine registered more than 200°F. The final sanitizing was 141°F at the plate surface. There was no indication of steam at the final rinse nozzles.
Recommendation: Ensure that water temperature measuring devices: (1) That are scaled in Celsius or dually scaled in Celsius and Fahrenheit are designed to be accurate to ±1.5°C in the intended range of use. (2) That are scaled only in Fahrenheit are designed to be accurate to ±3°F in the intended range of use.
Item No.: 27
Site: Bar-Topsider
Violation: The floor of the portside technical compartment (below the speedrail) was soiled.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Bar-Topsider
Violation: The deck in the starboard side technical compartment (below the speedrail) was peeling, flaking, and bubbled, making cleaning difficult.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 21
Site: Bar-Piano
Violation: There were drain pipes draped on the floor of the technical compartment below the speedrail, making cleaning difficult.
Recommendation: Shorten the drain pipes or provide supports to keep them off the floor of the technical compartment.
Item No.: 33
Site: Pantry-Piano
Violation: The deck surface was rough, cracked, and bubbled, making cleaning difficult.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 33
Site: Bar-Main Salon
Violation: This area was not coved. There were a few cracked deck tiles at the entryway.
Recommendation: Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters). Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 08
Site: Galley-Main Salon
Violation: There was an atmospheric vacuum breaker type backflow preventer on the coffee machine. There was a valve downstream of the backflow preventer.
Recommendation: Ensure that a continuous pressure-type backflow preventer is installed when a valve is located downstream from the backflow preventer.
Item No.: 17
Site: Provisions-Parasite Destruction Letter
Violation: The letter did not specify the species of fish.
Recommendation: Ensure that, if raw, raw-marinated, partially cooked, or marinated-partially cooked fish are served in ready-to-eat form: (1) The person in charge records the freezing temperature and time to which the fish are subjected and retains the records on the vessel for 90 calendar days beyond the time of service or sale of the fish; or (2) If the fish are frozen by a supplier, a written letter from the supplier which specifies the fish species involved and both the temperature to which the fish was frozen and the total time period at that temperature. If the supplier provides any of the same species to the vessel in a fresh state, there shall be some designation on the outer packaging for the parasite-free fish.
Item No.: 33
Site: Galley-Soup Station
Violation: A portion of the deck behind the soup kettle was pitted, flaking and bubbled, making cleaning difficult.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.