Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Ventura Cruise Line: P&O Cruises Inspection Date: 11/04/2009 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 27
Site: Buffet-Cold Cereal Island - Starboard
Violation: The technical compartment floor under the compressor shelf was soiled.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Buffet-Beverage Station - Starboard
Violation: There was plastic film and tape on the walls of the technical compartment, making cleaning difficult.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Buffet-Midships Work Area
Violation: The floor of the technical compartment was soiled and there was mold in the deck drain.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Buffet-
Violation: The floor and deck drain in technical compartment WSF3 were soiled.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Buffet-
Violation: There was mold on the refrigerant lines in technical compartment WSCW16.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Galley-Beach House
Violation: There was mold on the pipe insulation in technical compartment BH4.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 36
Site: Galley-Beach House
Violation: The stack oven interior lights were inoperable. The top stack oven right-side light shield was broken. A work under had been submitted.
Recommendation: Repair the lights.
Item No.: 21
Site: Buffet-Beach House
Violation: The induction cook top surfaces were damaged and rough, making cleaning difficult.
Recommendation: Ensure that nonfood-contact surfaces of equipment and utensils are designed and constructed to be durable and to retain their characteristic qualities under normal use conditions.
Item No.: 08
Site: Buffet-Beach House - Aft Coffee Station
Violation: The backflow preventer was leaking. There was mold and mineral deposits on the backflow preventer.
Recommendation: Ensure that backflow preventers are maintained in good repair.
Item No.: 36
Site: Other-Frankie's Pizzeria
Violation: The stack oven interior lights were inoperable. A work order had been submitted.
Recommendation: Repair the lights.
Item No.: 27
Site: Other-Frankie's Pizzeria
Violation: There was mold on the floor around the supports of technical compartment FPF2.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Other-Frankie's Pizzeria
Violation: The deck below the dishwash machine was soiled.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 33
Site: Galley-East Room
Violation: The deck under the coffee machine was soiled. This area had been previously cleaned.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 33
Site: Galley-Deck 6 - Saffron Side
Violation: There was a loose profile strip at the right-side of the wine bar entry door.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 21
Site: Galley-Deck 6 - Saffron Side
Violation: A three-shelf trolley was damaged, leaving open seams, cracks and other difficult to clean features. There was also a damaged trolley in the deck 5 main galley.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance. Ensure that non-food contact equipment is maintained in good repair and proper adjustment including: (1) Equipment maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines. (2) Equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact, tight, and adjusted in accordance with manufacturer's specifications.
Item No.: 21
Site: Galley-Deck 6 - Ice Cream Station
Violation: The microwave oven was mounted less than 1 inch above the shelf, inhibiting access for cleaning. The shelf below the oven was soiled.
Recommendation: Ensure that table-mounted equipment that is not easily movable is installed to allow cleaning of the equipment and areas underneath and around the equipment by being: (1) Sealed to the table; or (2) Elevated on legs.
Item No.: 36
Site: Galley-Deck 5 - Pastry
Violation: The stack oven interior lights were inoperable. A work order had been submitted.
Recommendation: Repair the lights.
Item No.: 08
Site: Pantry-Officer's Mess
Violation: The backflow prevention device was shared for the ice machine and the juice machine.
Recommendation: Provide separate back flow prevention devices for ice machine and the juice machine.
Item No.: 08
Site: Potable Water-
Violation: The backflow prevention devices for the crew and passenger cabin toilets, shower hoses on whirlpool tubs, and public toilets were not listed in the cross-connection control program.
Recommendation: Ensure that the cross-connection control program includes at minimum: a complete listing of cross-connections and the backflow prevention method/device for each, so that there is a match to the plumbing system component and location, and an inspection frequency. Ensure that air-gaps are included in the listing.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program