Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Azamara Journey Cruise Line: Azamara Cruises Inspection Date: 01/03/2010 Inspection Score: 98
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 02
Site: Medical-Medical - Records
Violation: The output report for the standardized gastrointestinal illness surveillance log is missing the cabin number. The cabin number can be found thru a different mechanism in the electronic medical database, as it is entered as part of the GI surveillance log data.
Recommendation: Ensure that a standardized gastrointestinal illness surveillance log for each cruise is maintained daily by the master of the vessel, the medical staff, or other designated staff. The gastrointestinal illness surveillance log entry for each passenger or crew member shall contain the following information: (1) The first date of clinic visit or report to staff of illness; (2) The person's name, age and gender; (3) A designation as passenger or crew member; (4) Crew member position or job on the vessel, if applicable; (5) Cabin number; (6) Meal seating information; (7) Date and time of illness onset; (8) Illness symptoms, including the presence of the following selected signs and symptoms: numbers of episodes each of diarrhea and vomiting per day, bloody stools, fever, recorded temperature, abdominal cramps, headaches and muscle aches; (9) Notation on whether or not a stool specimen was requested and received; (10) Use of antidiarrheal medication; and (11) The presence of underlying medical conditions which may affect interpretation of acute gastrointestinal illness for example diabetic diarrhea, inflammatory bowel disease, gastrectomy or others.
Item No.: 08
Site: Potable Water-Potable Water - Tank Coating Documentation
Violation: During a planned maintenance on 30 April 2009, potable water tank #2222 was partly coated in areas of deterioration with a two component epoxy from the same manufacturer. The first component (Interline 925) had a certification for potable water tanks that was found thru an internet search onboard and printed, but the second (Interline 974) was certified according to the manufacturer by both the Norwegian Institute of Health and WRC BS6920, Part 1. There was no record of same and we could not retrieve such a document from an internet search of either approval. Lastly, the written record of the use of these products for the 30 April re-coating did not include a statement that the paint was applied, dried, and cured according to the manufacturer's recommendations.
Recommendation: Ensure that interior coatings on potable water tanks are approved for potable water contact, and all manufacturer's recommendations for application, drying, or curing are followed. Ensure written documentation for the coating used and recommendations followed are available for review during inspections.
Item No.: 10
Site: DO NOT USE (whirlpool/spa)-Whirlpool Spas 1 and 2 - Records
Violation: The manual record for the daily monitoring of halogen and pH on whirlpool spas 1 and 2 noted only one reading for both on the log form, so one value was given for both whirlpools, rather than the actual values for spa #1 and another page with actual values for spa #2.
Recommendation: Record the whirlpools spa chemistry for each whirlpool separately.
Item No.: 21
Site: Bar-Martini Bar
Violation: There was missing sealant along sections of the bar top, where the stone pieces joined, which left a difficult to clean seam.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 33
Site: Provisions-Fish
Violation: The deck was soiled below the deck stands along the port deck/bulkhead juncture.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 19
Site: Provisions-Meat Freezer
Violation: There was frozen condensation on the deckhead throughout. A few boxes of frozen foods had small ice mounds on the top. One box had frozen liquid on two sides.
Recommendation: Ensure that food is protected from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
Item No.: 37
Site: Provisions-Meat Freezer
Violation: There was frozen condensation on the deckhead throughout. A few boxes of frozen foods had small ice mounds on the top. One box had frozen liquid on two sides.
Recommendation: Ensure that ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads. Ensure that ventilation hood systems and devices operate effectively to prevent grease and condensate from collecting on the bulkheads and deckheads and remove contaminants generated by equipment located under them.
Item No.: 34
Site: Provisions-Meat Freezer
Violation: There was a mound of frozen liquid from a joint in the condenser drain to the deck below. The deck in this area was covered with ice from the bulkhead/deck juncture out to approximately 0.5 meters. No foods were stored in this area.
Recommendation: Ensure that a plumbing system in a food area is maintained in good repair.
Item No.: 33
Site: Preparation Room-
Violation: There were a few damaged deck tiles in this area.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 33
Site: Provisions-Dry Stores
Violation: The deck was soiled below the deck stands at the deck/bulkhead junctures.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 33
Site: Provisions-Dry Stores
Violation: A few deck tiles were damaged at the entry door and at points were the deck stands contact the deck.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 33
Site: Provisions-Liquor Stores
Violation: The deck was soiled below the deck stands at the deck/bulkhead junctures.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 22
Site: Galley-Dishwash
Violation: The final rinse temperature gauge was reading in excess of 220°F. The final rinse temperature at the plate surface was measured at 170°F, there was no steam noted during the final rinse cycle, and the final rinse spray pattern was correct with no clogging observed, indicating that the mounted thermometer may be inaccurate.
Recommendation: Ensure that warewashing equipment is maintained in good repair and proper adjustment including: (1) Being maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; and (2) Maintaining water pressure, and water temperature measuring devices in good repair and ensuring their accuracy within the intended range of use.
Item No.: 33
Site: Galley-Dishwash
Violation: The grout around the stainless steel/tile juncture below the clean end was recessed.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 16
Site: Buffet-
Violation: There was a large, covered hotel pan of butter pats on the upper shelf of undercounter refrigeration unit 3.2 with an internal temperature of 45°F. The pan was immediately placed in the blast chiller.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
Item No.: 21
Site: Galley-
Violation: The pipe insulation was damaged in technical space 3.5.
Recommendation: Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material. Ensure that nonfood-contact surfaces of equipment and utensils are designed and constructed to be durable and to retain their characteristic qualities under normal use conditions. Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Galley-
Violation: The floor was soiled in technical space 3.6.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Galley-Meat Preparation
Violation: The deck below technical space 4.25 was soiled at the deck/bulkhead juncture.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary. Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 18
Site: Galley-Meat Preparation - Walk-in Refrigerator
Violation: Raw ground beef was stored above whole cuts of raw beef. This was immediately corrected.
Recommendation: Ensure that food is protected from cross-contamination by: (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry during storage, preparation, holding, and display by using separate equipment for each type, or arranging each type of food in equipment so that cross-contamination of one type with another is prevented, and preparing each type of food at different times or in separate areas.
Item No.: 33
Site: Galley-Meat Preparation
Violation: The deck below the pulper was soiled. Per staff the pulper is not used.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 33
Site: Galley-Pastry/Bakery
Violation: There were a few damaged deck tiles and some recessed grout in this area.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 38
Site: Galley-Pastry/Bakery
Violation: The proofer oven was posted "Out of Service". Per staff, the vessel has been waiting for parts for more than 4 months.
Recommendation: Ensure that only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
Item No.: 36
Site: Galley-Pastry/Bakery
Violation: The stack oven interior lights were not functioning.
Recommendation: Ensure that the stack oven lights are functional.
Item No.: 21
Site: Galley-
Violation: There was excessive sealant around the technical control panel cover.
Recommendation: Remove the excess sealant.
Item No.: 21
Site: Galley-Hot Line
Violation: There were two damaged plate covers. They were discarded.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Galley-Garde Manger
Violation: The interior of the four refrigeration unit technical spaces were soiled.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris. Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Galley-Garde Manger
Violation: There were a few damaged tiles and recessed grout near the Buffalo chopper.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair. Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 40
Site: Room Service-
Violation: The outer door to the open deck area was pinned open.
Recommendation: Ensure that entry points where pests may enter the food areas are protected.
Item No.: 33
Site: Room Service-Wine Cellar
Violation: There was a void space in the pipe penetration where the multi-flow lines had been removed.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair. Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 28
Site: Dining Room-
Violation: A few of the green silverware racks had the eating utensils stored with the mouth contact ends facing up.
Recommendation: Ensure that clean equipment and utensils are stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
Item No.: 27
Site: Buffet-Windows Cafe
Violation: There was loose insulation and other debris on the floor of the technical space below the port soup kettle.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 22
Site: Galley-Dishwash
Violation: The final rinse temperature gauge was reading in excess of 220°F and steam was being released from the final rinse spray nozzles. The final rinse temperature was measured at 170°F at the plate surface.
Recommendation: Ensure that warewashing equipment is maintained in good repair and proper adjustment including: (1) Being maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; and (2) Maintaining water pressure, and water temperature measuring devices in good repair and ensuring their accuracy within the intended range of use.
Item No.: 33
Site: Buffet-Windows Cafe
Violation: The coving installed along the juncture of the buffet counters on the passenger side at the port and starboard soup stations had failed. There was a small open seam at this point where the coving material met with the wooden kick plate.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 33
Site: Buffet-Windows Cafe - Outdoor Aft Beverage Station
Violation: There was a soft sail cloth directly above the beverage counter. The large gaps between the cloth sections allow debris to fall from the area above.
Recommendation: Ensure that bulkheads and deckheads have smooth, hard finishes, and light colored surfaces.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program