Cruise Ship: Seven Seas Mariner Cruise Line: Regent Seven Seas Inspection Date: 01/04/2010 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 21
Site: Bar-Pool Bar
Violation: There were 2 openings in technical compartment 346 around the pipe penetrations in the back of the compartment.
Recommendation: Cover the openings and seal around the pipe penetrations.
Item No.: 19
Site: Buffet-La Veranda
Violation: There were cheese and crackers served by a crew member. The cheese was under a retractable dome that was only accessible by the crew member, but the crackers were not protected. The crackers were replaced and new crackers were placed under the dome.
Recommendation: Ensure that food on display is protected from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; or other effective means.
Item No.: 16
Site: Buffet-La Veranda
Violation: The undercounter refrigeration units that are used for time control are labeled, but they were not listed on the time as a public health control plan.
Recommendation: Ensure that any refrigeration or hot holding units used for the time as a public health control plan are listed on the plan.
Item No.: 19
Site: Buffet-Pool Grill
Violation: There was a display/serving cabinet used for self service of pastries for passengers. The cabinet doors were not self-closing. Also, the tongs for serving the pastries was located on a plate on the counter in front of the cabinet.
Recommendation: Ensure that self service items are protected from contamination by a passive means that does not require the consumer to cover the items or close a door.
Item No.: 21
Site: Buffet-Pool Grill
Violation: There was tape on the holes on the front of the fryers.
Recommendation: Remove the tape and replace with a plastic plug.
Item No.: 36
Site: Dining Room-Signatures
Violation: The light level at the waiter station could not be raised to 220 lux.
Recommendation: Ensure that the light intensity is at least 220 Lux (20 foot candles) in bars and at dining room waiter stations during periods of cleaning.
Item No.: 33
Site: Galley-Signatures
Violation: Behind the Cecilware coffee machine, the electrical conduit was separating from the bulkhead.
Recommendation: Secure the conduit and seal to the bulkhead.
Item No.: 19
Site: Galley-Pastry
Violation: There was a large uncovered container of butter on the top of a trolley in the walk-in freezer.
Recommendation: Ensure that containers in walk-in refrigeration and freezer units are covered.
Item No.: 21
Site: Galley-
Violation: In the technical compartment for the blast chiller, there were 2 holes in the back of the compartment around the pipe penetrations.
Recommendation: Cover the openings and seal around the pipe penetrations.
Item No.: 28
Site: Galley-Prime 7
Violation: Several stacks of small plates were not covered or inverted.
Recommendation: Ensure that clean equipment and utensils are stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
Item No.: 11
Site: Medical-
Violation: Close contacts of ill crew members were isolated for 24 hours. The nurse stated that close contacts are telephoned the day after isolation to ensure they are not sick, but this 48-hour interview was not recorded.
Recommendation: Ensure that medical staff conduct daily verbal interviews with asymptomatic crew until 48 hours after onset of the ill crew members symptoms. Ensure that the interviews are documented.