|
|
|
Item No.:
16
|
|
Site:
Galley-Cold Pantry
|
|
Violation:
There was a large container of Radicchio that had temperatures that ranged from 43°F to 45°F. The production date of the salad was 5 April 2011. The lettuce was blast chilled.
|
|
Recommendation:
Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
|
|
|
Item No.:
16
|
|
Site:
Galley-Walk-In Refrigerator - Soup Station
|
|
Violation:
There were two medium metal containers of cabbage that had temperatures that ranged from 42°F to 45°F. The production date of the cabbage was 5 April 2011. The cabbage was blast chilled.
|
|
Recommendation:
Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
|
|
|
Item No.:
21
|
|
Site:
Galley-Soup Station
|
|
Violation:
The handle for the tilting kettle had a grove along the back that made cleaning difficult.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
27
|
|
Site:
Galley-Pot Wash
|
|
Violation:
The undercounter space and bulkhead along the soiled landing of the pulper had an accumulation of dried food debris and residue.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
22
|
|
Site:
Galley-Pot Wash
|
|
Violation:
There was a leak coming from the door of the potwash machine.
|
|
Recommendation:
Ensure that warewashing equipment is maintained in good repair and proper adjustment including: (1) Being maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; and (2) Maintaining water pressure, and water temperature measuring devices in good repair and ensuring their accuracy within the intended range of use.
|
|
|
Item No.:
20
|
|
Site:
Galley-Pastry / Bakery
|
|
Violation:
There was paint that chipped along the mixer shaft of the center deck mounted mixer.
|
|
Recommendation:
Ensure that materials used in the construction of multiuse utensils and food-contact surfaces of equipment are: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
|
|
|
Item No.:
37
|
|
Site:
Galley-Warewash
|
|
Violation:
There was excessive steam generated from the flight-type warewash machine along the soiled landing. There was some condensate collecting above the soiled landing.
|
|
Recommendation:
Ensure that ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
|
|
|
Item No.:
22
|
|
Site:
Galley-Warewash
|
|
Violation:
There was one final rinse spray nozzle that did not spray an effective pattern.
|
|
Recommendation:
Ensure that warewashing equipment is maintained in good repair and proper adjustment including: (1) Being maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; and (2) Maintaining water pressure, and water temperature measuring devices in good repair and ensuring their accuracy within the intended range of use.
|
|
|
Item No.:
19
|
|
Site:
Galley-Lido Grill - Induction Plate
|
|
Violation:
The hot plate (induction plate) located along the lido grill was not protected by a sneeze guard.
|
|
Recommendation:
Ensure that food on display is protected from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; or other effective means.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Microbiological Sampling
|
|
Violation:
There were three times in March 2011 where potable water samples tested positive for coliforms. There was no documented results for E. Coli testing. The staff stated that they did the checks for the presence of E. Coli and they were negative but the results were not recorded.
|
|
Recommendation:
Ensure that these records are maintained on the vessel for 12 months and available to the VSP for review during inspections.
|
|
|
Item No.:
28
|
|
Site:
Pantry-Deck 10
|
|
Violation:
There were already cleaned plates, cups, and carafes directly under the counter designated as dirty area. There were also trays with previously cleaned wine glasses and ice buckets placed above this dirty area. This pantry was not in use at the time of the inspection.
|
|
Recommendation:
Ensure that cleaned equipment and utensils, laundered linens, and single-service and single-use articles are stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 150 mm (6 inches) above the deck.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Pantry Deck 10
|
|
Violation:
The backflow preventers installed in the potable water lines going to the coffee maker and the hot water boiler were leaking.
|
|
Recommendation:
Ensure that backflow preventers are maintained in good repair.
|
|
|
Item No.:
41
|
|
Site:
*General Comments-Ventilation
|
|
Violation:
The condensate collection pans for ventilation units ACR 503 and ACR 507 were not accessible for inspection, maintenance, and cleaning. There was no sight glass or other effective method available for full inspection and cleaning. Per staff, all air handling units have this design.
|
|
Recommendation:
Ensure that air handling unit condensate drain pans and collection systems are accessible for inspection, maintenance, and cleaning.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Tank Maintenance Records
|
|
Violation:
On 22 March 2011 the interior of the potable water tank FW 1P was inspected, painted, washed, and chlorinated. There was no documentation indicating the details of the painting procedure, including those details for drying and curing times.
|
|
Recommendation:
Ensure that interior coatings on potable water tanks are approved for potable water contact, and all manufacturer's recommendations for application, drying, or curing are followed. Ensure written documentaion for the coating used and recommendations followed are avaialble for review during inspections.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-Training Records
|
|
Violation:
The training of the Integrated Pest Management Manager, as part of the pest control personnel, was not documented in the IPM Plan.
|
|
Recommendation:
Ensure that the Integrated Pest Management Plan includes provisions for active monitoring including pest sighting logs for the operational areas of the vessel and training for crew members in charge of log completion.
|
|