Cruise Ship: Seadream II Cruise Line: Sea Dream Yacht Club Inspection Date: 04/08/2011 Inspection Score: 99
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 08
Site: Potable Water-Starboard Hose Locker
Violation: One hose was not labeled "potable water only" at both connecting ends.
Recommendation: Ensure that potable water hoses are labeled for use with the words "potable water only" in letters at least 13mm (0.5 inch) at each connecting end.
Item No.: 35
Site: Galley-
Violation: The drain line for upright refrigerator 18 was not directed to a scupper or deck drain. Water was draining directly on the deck. It appeared that a piece of the drain pipe was missing.
Recommendation: Ensure that the drain line is directed to a scupper or deck drain.
Item No.: 35
Site: Galley-
Violation: The drain lines from both the ice bin and technical compartment for the ice machine were not directed to a scupper or deck drain. Water was draining directly on the deck.
Recommendation: Ensure that the drain lines are directed to a scupper or deck drain.
Item No.: 27
Site: Galley-
Violation: In the hot section, the underside of the front edges of the flat top, griddle, and cook tops were soiled.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Galley-
Violation: The concrete pad below the cooking equipment was rough and difficult to clean. It appeared to be soiled. This was noted on the previous inspection.
Recommendation: Ensure that surfaces subject to routine splashes, spillage, or other soiling during normal use have easily cleanable features. Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 20
Site: Galley-
Violation: There were slotted fasteners around the light box inside the oven.
Recommendation: Replace the fasteners with smooth, low profile, non-slotted, non-corroding fasteners.
Item No.: 33
Site: Galley-
Violation: There was an unsealed penetration around the cable for the bulkhead mounted door magnet for the door to the mooring deck.
Recommendation: Close the penetration.
Item No.: 40
Site: Galley-
Violation: The door to the mooring deck was open.
Recommendation: Ensure that entry points where pests may enter the food areas are protected.
Item No.: 39
Site: Galley-
Violation: There was a fly in the dishwash area.
Recommendation: Ensure that the presence of insects, rodents, and other pests is effectively controlled to minimize their presence in the food storage, preparation, service areas, warewashing, and utensil storage areas aboard a vessel.
Item No.: 19
Site: Provisions-Vegetable Freezer
Violation: The covers and sides of a few of the containers of ice cream were damaged, exposing the ice cream.
Recommendation: Ensure that the ice cream is not stored in damaged containers and that the ice cream is protected from exposure to contamination.
Item No.: 33
Site: Provisions-Meat Freezer
Violation: The deck tiles at the entrance to the freezer were cracked and damaged.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 21
Site: Bar-Main Salon
Violation: There was raw wood in the bottle storage cabinet below the window.
Recommendation: Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 20
Site: Pantry-5
Violation: There were slotted fasteners around the light box inside the oven.
Recommendation: Replace the fasteners with smooth, low profile, non-slotted, non-corroding fasteners.
Item No.: 29
Site: Bar-Top of the Yacht
Violation: There was no handwashing station in the bar. The nearest handwashing station was in the pantry, which was more than 8 meters away. However, there was a swinging door to the pantry, and the user would not have to pass through a closed door.
Recommendation: Ensure that each food preparation area, bar, warewashing area, and garbage-processing area has at least one handwashing facility located in it. Ensure that the handwashing facility is located within 8 m (25 feet) of all parts of the area and is not located in an adjacent area that requires passage through a closed door. where the user makes hand contact with the door.
Item No.: 33
Site: Pantry-Top of the Yacht
Violation: There was no coving at the deck/bulkhead juncture next to and behind the ice machine.
Recommendation: Ensure that bulkhead and deck junctures are coved (including galleys, pantries, deck/counter junctures at buffets, bars, waiter stations, and dining room work counters).
Item No.: 08
Site: Potable Water-Bunkering
Violation: There were no free halogen residual and pH tests conducted on the shoreside water supply before starting the bunkering process. The vessel had only bunkered potable water four times in the past 4 months.
Recommendation: Ensure that a halogen residual and pH test is conducted on the shore-side water supply before starting the bunkering process to establish the correct halogen dosage. Record the results of this pretest and have available for review during inspections.
Item No.: 08
Site: Potable Water-Cross-Connection Control Program
Violation: The air gap for the technical water filling from potable water was not listed on the cross-connection control plan.
Recommendation: Ensure that the air gap is listed on the cross-connection control plan.